Search results for "Airflow"
showing 10 items of 42 documents
Development of a Sensor for Continuous and Accurate Monitoring of Air Flow for Open-System Whole Canopy Gas-Exchange Measurements
2007
The research describes the development and set-up of a simple and accurate solid-state device for continuous monitoring of airflow forced into an open-flow gas-exchange chamber for whole-canopy transpiration and photosynthesis measurements. The ventilation system was formed by a centrifugal fan powered by an electric motor and a PVC pipe (0.193 m inner diameter). To damp airflow turbulence, 50 cm of the main pipe was filled with a bundle of smaller PVC pipes (3 cm inner diameter). The measurement principle of the sensor is the thermal balance of an electrically heated copper plate compared to an unheated one. Calibration of the sensor was performed by two independent methods: gas dilution (…
Salbutamol Transport and Deposition in the Upper and Lower Airway with Different Devices in Cats: A Computational Fluid Dynamics Approach
2021
Simple Summary Administration of inhaled salbutamol via metered-dose inhalers can effectively treat bronchoconstriction. Different devices are used for the delivery of this drug in cats, either in the hospital or at home, for long-term treatment. Effective drug administration may depend on the drug delivery device as well as patient cooperation. By using non-invasive computational fluid dynamics techniques, the impact of these devices on the deposition and transport of salbutamol particles in the cat airways was simulated and assessed. The results confirm a variable drug distribution depending on the device used. The percentage of particles reaching the lung was reduced when using spacers a…
Experimental and Numerical Analysis of Air Flow, Heat Transfer and Thermal Comfort in Buildings with Different Heating Systems
2016
Abstract Monitoring of temperature, humidity and air flow velocity is performed in 5 experimental buildings with the inner size of 3×3×3 m3 located in Riga, Latvia. The buildings are equipped with different heating systems, such as an air-air heat pump, air-water heat pump, capillary heating mat on the ceiling and electric heater. Numerical simulation of air flow and heat transfer by convection, conduction and radiation is carried out using OpenFOAM software and compared with experimental data. Results are analysed regarding the temperature and air flow distribution as well as thermal comfort.
Three-mode pneumatic management of marine U-tank systems
2012
Abstract This paper deals with a new pneumatic control strategy for the roll damping enhancement of marine U-tank stabilizers. The proposed technique consists in a three-mode operation, where the control is active only within a limited resonant range around the ship natural frequency, whereas the control valves are kept closed in the remaining frequency range. Moreover the connection valve between the two air chambers is either closed or partially opened for the low or high frequencies, respectively. The pressurized air for the active control is fed by a turbo-blower set aboard and operates accelerating the motion of the water mass in the U-duct. The theoretical analysis is conducted in the…
Non-dimensional groups for air solar collectors
2003
Abstract The radiant heat captured by a passive air solar collector during a day divides itself into three fractions, of which one is transmitted by conduction to the backside, one is collected by the convective air flow, and the last one is lost through glazing. Some calculations of heat transfer taking place in a collector in 24-h periodic regime have been done with different combinations of the values of the relevant thermo-physical variables. Calculation results were the fractions of energy transmitted to the internal room through the wall by conduction and with the air flow by convection, and lost through the glazing. The results give rise to a correlation among non-dimensional variabl…
Heat transfer calculation in a free convection air solar collector
1998
This paper deals with the free convective air flow developing in a vertical channel with a rectangular cross-section heated on one side. The channel geometric and physical properties are such as to simulate an air solar collector suitable for building heating. A calculation method that can be applied to the transient combined heat transfer by conduction through the wall and by convection from the wall to the air stream is presented. The conduction across the wall is computed with a one-dimensional, time-dependent finite difference scheme, with convective boundary conditions at both wall surfaces. For the free convective flow along the channel, the air flow rate and the mean convective coeff…
Update on desiccant wheel model
2004
This short communication presents the update on the desiccant wheel models, developed earlier by the present authors. It is to be mentioned here that the psycrometric model presented earlier (Int. J. Energy Res., 2003; 27:17) is valid only for the desiccant wheel running with identical volume air-flows in supply and regeneration sides. However, when system runs with volume air flow ratio between supply and regeneration side (α), different from 1 (one), the model need further modifications. In the present work, correction factors were developed and incorporated in order to update the earlier model for predicting correctly the temperature and humidity of processed air at the outlet of desicca…
APPLICATION OF MATHEMATICAL MODELS FOR THE SIMULATION OF THERMAL COMFORT CONDITIONS IN A LIVING ROOM
2005
The paper deals with the distributions of temperature and averaged turbulent airflows in living rooms in 2D and 3D approximations using Ansys/Flotran and Ansys/CFX software respectively. The distributions are calculated depending on the placement and temperature of heaters, heat transfer coefficients of the building structures and ventilation conditions. The authors analyse the influence of these factors on the air circulation and the related heat flows through building structures. The thermal balance of a room and its dependence on various external factors is also considered. As thermal comfort conditions’ parameters are analysed, the airflow velocities and indoor temperatures with its gra…
Impact of wind speed on ventilation performance within a container installed with photovoltaic inverter
2017
Abstract PV inverter needs proper ventilation for reducing the heat dissipation of the electronic components. In this work, a container installed with PV inverter is considered with different configurations of cooling channels within the container for ventilation analysis. Typically, high capacity PV inverters are installed inside the container and therefore inverters, are not experiencing external wind effects and it depends on the configuration of cooling channels. In this work, the main cooling channel is located at the top of the inverter; inlet and outlet ventilation holes are located on the side of cross ventilation. They help in analyzing the cooling design, dependent on site specifi…
Fire safety investigation for road tunnel ventilation systems – An overview
2014
Abstract In recent years, research activities about fire events in tunnel have received a significant impulse, especially after several accidents. The Computational Fluid Dynamic (CFD) has a fundamental role about. Researchers have spent resources on various topics involving numerical tools as the performance of a ventilation system, the influence of this on the air flow motion in the tunnel or the methods for fire schematization, fire-induced smoke characterization, turbulence models, etc. One of the main phenomena to consider for the safety when a fire occurs in a tunnel is the possibility of the fire-induced smoke to rise the tunnel (backlayering). A well-designed ventilation system shal…