Search results for "Algorithm"
showing 10 items of 4887 documents
Low Complexity Image Compression using Pruned 8-point DCT Approximation in Wireless Visual Sensor Networks
2017
International audience; Since the transmission of the uncompressed image in the context of wireless visual sensor networks (WVSNs) consumes less energy than transmitting the compressed image, developing energy-aware compression algorithms are mandatory to extend the camera node's lifetime and thereby the whole network lifetime. The present paper studies a low-complexity image compression algorithm in the context of WVSNs. This algorithm consists of applying a pruning approach on a DCT approximation transform. The scheme is investigated in terms of computation cycles, processing time, energy consumption and image quality. Experimental works are conducted using the Atmel Atmega128 processor o…
Emission tomography with a large-hole collimator (CACAO): a possible new way to improve radionuclide imaging.
2002
This work aims to improve the quality of scintigraphy. It evaluates the use of a large-hole collimator, the Computer Aided Collimation Gamma Camera Project (CACAO), in SPECT. Acquisition data from the same object were simulated for CACAO and for a conventional collimator. Better signal-to-noise ratios were found for CACAO images, whatever the number of emitted photons. This work demonstrates that high-resolution images may be obtained with large-hole collimators. The combination of CACAO and pixilated detectors may further improve radionuclide imaging.
Diffusion equations with negentropy applied to denoise mammographic images.
2006
Mammography is a radiographic technique used for the detection of breast lesions. The analysis of the digital image normally requires a previous application of filters as a preprocessing step to reduce the noise level of the image, while preserving important details to carry out a suitable diagnostic. In the literature, there are a large amount of denoising techniques applied to different medical images. In this work we have studied the performance of a diffusive filter with a stopping condition based on the statistical concept of negentropy, applied to denoise mammographic images. The negentropy has been succesfully prove with other denoising methods as independent component analysis by th…
Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.
2019
Purpose Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to develop a marker-free iterative motion correction algorithm that works on the projection images and is suitable for local tomography. Methods We present an iterative motion correction algorithm that allows the patient's motion to be detected and taken into account during reconstruction. The core of our method is a fast GPU-accelerated three-dimensional reconstruction algorith…
Dissecting and Reassembling Color Correction Algorithms for Image Stitching
2018
This paper introduces a new compositional framework for classifying color correction methods according to their two main computational units. The framework was used to dissect fifteen among the best color correction algorithms and the computational units so derived, with the addition of four new units specifically designed for this work, were then reassembled in a combinatorial way to originate about one hundred distinct color correction methods, most of which never considered before. The above color correction methods were tested on three different existing datasets, including both real and artificial color transformations, plus a novel dataset of real image pairs categorized according to …
Comparison of Elastic and Rigid Registration during Magnetic Resonance Imaging/Ultrasound Fusion-Guided Prostate Biopsy: A Multi-Operator Phantom Stu…
2018
The relative value of rigid or elastic registration during magnetic resonance imaging/ultrasound fusion guided prostate biopsy has been poorly studied. We compared registration errors (the distance between a region of interest and fiducial markers) between rigid and elastic registration during fusion guided prostate biopsy using a prostate phantom model.Four gold fiducial markers visible on magnetic resonance imaging and ultrasound were placed throughout 1 phantom prostate model. The phantom underwent magnetic resonance imaging and the fiducial markers were labeled as regions of interest. An experienced user and a novice user of fusion guided prostate biopsy targeted regions of interest and…
Role of apparent diffusion coefficient values in prostate diseases characterization on diffusion-weighted magnetic resonance imaging.
2019
BACKGROUND: To evaluate if normal and pathological prostate tissue can be distinguished by using apparent diffusion coefficient (ADC) values on magnetic resonance imaging (MRI) and to understand if it is possible to differentiate among pathological prostate tissues using ADC values.METHODS:Our population consisted in 81 patients (mean age 65.4 years) in which 84 suspicious areas were identified. Regions of interest were placed over suspicious areas, detected on MRI, and over areas with normal appearance, and ADC values were recorded. Statistical differences between ADC values of suspicious and normal areas were evaluated. Histopathological diagnosis, obtained from targeted biopsy using MRI-…
Approaches to find complementary separation conditions for resolving complex mixtures by high-performance liquid chromatography
2012
Chromatographic problems are usually addressed trying to find out a single experimental condition aimed to resolve all compounds in the sample. However, very often, the chromatographic system is not able to provide full resolution. When a separation fails, the usual choice is introducing a drastic change in the chromatographic system (e.g. column, solvent, pH). There are, however, other possibilities that take advantage of the gathered information in the failed separation, without the need of new experiments, based on the concept of complementary separations (e.g. isocratic mobile phases, gradients, columns, chromatographic modes). One separation condition will focus on the resolution of so…
Scalable Constant pH Molecular Dynamics in GROMACS
2022
Molecular dynamics (MD) computer simulations are used routinely to compute atomistic trajectories of complex systems. Systems are simulated in various ensembles, depending on the experimental conditions one aims to mimic. While constant energy, temperature, volume, and pressure are rather straightforward to model, pH, which is an equally important parameter in experiments, is more difficult to account for in simulations. Although a constant pH algorithm based on the λ-dynamics approach by Brooks and co-workers [Kong, X.; Brooks III, C. L. J. Chem. Phys.1996, 105, 2414–2423] was implemented in a fork of the GROMACS molecular dynamics program, uptake has been rather limited, presumably due to…
Association between human papillomavirus 16 E6 variants and human leukocyte antigen class I polymorphism in cervical cancer of Swedish women.
2003
Abstract Persistent infection with human papillomavirus (HPV), particularly HPV16, represents the prime risk factor in cervical carcinogenesis. HPV variants ( e.g. , within the E6 gene) together with immunogenetic factors of the host may be responsible either for effective viral clearance, or alternatively, for viral persistence. Peripheral blood from 27 HPV16 positive Swedish women with cervical carcinoma, who had previously been tested for HPV16 E6 variants, was used for human leukocyte antigen (HLA) class I typing. Women with HLA-B*44, HLA-B*51, or HLA-B*57 who were infected with the HPV16 E6 variant L83V had an approximately four- to fivefold increased risk for cancer compared with cont…