Analyzing assessors and products in sorting tasks: DISTATIS, theory and applications

2007

Abstract In this paper we present a new method called distatis that can be applied to the analysis of sorting data. D istatis is a generalization of classical multidimensional scaling which allows one to analyze 3-ways distance tables. When used for analyzing sorting tasks, distatis takes into account individual sorting data. Specifically, when distatis is used to analyze the results of an experiment in which several assessors sort a set of products, we obtain two types of maps: One for the assessors and one for the products. In these maps, the proximity between two points reflects their similarity, and therefore these maps can be read using the same rules as standard metric multidimensiona…

RV coefficientNutrition and DieteticsSimilarity (geometry)GeneralizationSortingcomputer.software_genreSet (abstract data type)Metric (mathematics)sortData miningMultidimensional scalingAlgorithmcomputerFood ScienceMathematicsFood Quality and Preference
researchProduct

The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.

2011

The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…

Radiation DosageComposite image filtersymbols.namesakeDigital imageOptical transfer functionMedian filterImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingGeneral DentistryMathematicsPixelPhantoms ImagingResearchGeneral MedicineRadiography Dental DigitalGaussian filterRadiographic Image EnhancementOtorhinolaryngologyGaussian noisesymbolsLinear ModelsArtifactsAlgorithmDigital filterAlgorithmsFiltrationDento maxillo facial radiology
researchProduct

Numerical expressions for the computation of coincidence-summing correction factors in γ-ray spectrometry with HPGe detectors

2009

Numerical expressions to compute gamma-gamma and gamma-X(K) coincidence summing corrections were deduced by using a suitable computer program and a matrix representation of a decay scheme. For point sources only full-energy peak and total efficiencies are needed. Alternatively, values of peak-to-total ratio can be introduced. For extended sources, the same expressions can be considered with the introduction of "effective efficiencies". Examples of the use of the expressions for point sources and a particulate filter sample measured with a 60% relative efficiency HPGe detector are reported.

RadiationDecay schemeComputer programSettore ING-IND/20 - Misure E Strumentazione NucleariComputationTransducersMatrix representationAnalytical chemistryReproducibility of ResultsEquipment DesignRadiation DosageCoincidence-summingSensitivity and SpecificitySample (graphics)CoincidenceComputational physicsEquipment Failure AnalysisSpectrometry GammaPoint (geometry)g-Ray spectrometryArtifactsRadiometryHpge detectorAlgorithmsMathematicsApplied Radiation and Isotopes
researchProduct

Topology design to reduce energy consumption of distributed graph filtering in WSN

2017

The large number of nodes forming current sensor networks has made essential to introduce distributed mechanisms in many traditional applications. In the emerging field of graph signal processing, the distributed mechanism of information potentials constitutes a distributed graph filtering process that can be used to solve many different problems. An important limitation of this algorithm is that it is inherently iterative, which implies that the nodes incur in a repeated communication cost along the exchange periods of the filtering process. Since sensor nodes are battery powered and radio communications are one of the most energy demanding operations, in this work, we propose to redesign …

Radio communicationsComputer scienceDistributed computing05 social sciences050801 communication & media studies020206 networking & telecommunicationsTopology design02 engineering and technologyEnergy consumptionNetwork topology0508 media and communicationsDistributed algorithm0202 electrical engineering electronic engineering information engineeringGraph (abstract data type)Current sensorWireless sensor network
researchProduct

Fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism

2001

The purpose of this study is to find fitted functional forms to the anisotropy function, F(r,θ), and the radial dose function, g(r), in order to characterize dose-rate distributions around all the high-intensity 192 Ir sources currently in use. Dosimetry data are at present available as tables for: the microSelectron HDR (“classic” and “new” design models), the PDR source, and the VariSource HDR source, expressed in terms of the AAPM Task Group No. 43 recommendations. There is only one paper out which introduces a functional form to fit the anisotropy function, but only for symmetric sources with respect to the transverse axis. However, dosimetric data of the HDR and PDR sources mentioned a…

RadioisotopesTask groupModels Statisticalmedicine.medical_treatmentBrachytherapyMathematical analysisTransverse axisGeneral MedicineModels TheoreticalIridiumFormalism (philosophy of mathematics)medicineAnisotropyDosimetryRadiometryDose rateAnisotropyMonte Carlo MethodAlgorithmMathematicsMedical Physics
researchProduct

Monte Carlo dosimetric study of the BEBIG Co-60 HDR source

2005

Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there are no dosimetric data available in the literature. The Monte Carlo code GEANT4 has been used to obtain the TG43 parameters and the 2D dose rate table in Cartesian coordinates of the BEBIG Co-60 HDR source. The dose rate constant, radial dose function and anisotropy function have been calculated and are presented in a tabular form as w…

Radiological and Ultrasound TechnologyPhantoms ImagingComputer scienceRadiotherapy Planning Computer-AssistedBrachytherapyMonte Carlo methodWaterRadiotherapy DosageHigh-Dose Rate BrachytherapyMonte carlo codeAnisotropyHumansRadiology Nuclear Medicine and imagingCobalt RadioisotopesRadiometryRadiation treatment planningDose rateMonte Carlo MethodAlgorithmSoftwareSimulationPhysics in Medicine and Biology
researchProduct

A Novel Approach of a Low-Cost UWB Microwave Imaging System with High Resolution Based on SAR and a New Fast Reconstruction Algorithm for Early-Stage…

2022

In this article, a new efficient and robust approach—the high-resolution microwave imaging system—for early breast cancer diagnosis is presented. The core concept of the proposed approach is to employ a combination of a newly proposed delay-and-sum (DAS) algorithm and the specific absorption rate (SAR) parameter to provide high image quality of breast tumors, along with fast image processing. The new algorithm enhances the tumor response by altering the parameter referring to the distance between the antenna and the tumor in the conventional DAS matrices. This adjustment entails a much clearer reconstructed image with short processing time. To achieve these aims, a high directional Vivaldi …

Radiology Nuclear Medicine and imagingComputer Vision and Pattern RecognitionElectrical and Electronic EngineeringCàncerEcografia mamàriaspecific absorption rate; microwave imaging; breast cancer detection; Vivaldi antenna; image reconstruction; confocal algorithmComputer Graphics and Computer-Aided DesignJournal of imaging
researchProduct

An Atmospheric Radiosounding Database for Generating Land Surface Temperature Algorithms

2008

A database of global, cloud-free, and atmospheric radiosounding profiles was compiled with the aim of simulating radiometric measurements from satellite-borne sensors in the thermal infrared. The objective of the simulated data is to generate split-window (SW) and dual-angle (DA) algorithms for the retrieval of land surface temperature (LST) from Terra/Moderate Resolution Imaging Spectroradiometer (MODIS) and Envisat/Advanced Along Track Scanning Radiometer (AATSR) data. The database contains 382 radiosounding profiles acquired over land, with nearly uniform distribution of precipitable water between 0.02 and 5.5 cm. Radiative transfer calculations were performed with the MODTRAN 4 code for…

RadiometerDatabaseMeteorologyMODTRANAATSRcomputer.software_genreBrightness temperatureRadianceNadirGeneral Earth and Planetary SciencesRadiometryEnvironmental scienceModerate-resolution imaging spectroradiometerElectrical and Electronic EngineeringAlgorithmcomputerRemote sensingIEEE Transactions on Geoscience and Remote Sensing
researchProduct

Estimation of sea surface temperature from SEVIRI data: algorithm testing and comparison with AVHRR products

2006

Three surface temperature (ST) algorithms for Spinning Enhanced Visible and InfraRed Imager (SEVIRI) data are developed and tested. A general split window algorithm for ST estimation, a sea surface temperature (SST) algorithm and a nonlinear algorithm (NLSST) developed for SEVIRI data. The test was carried out by comparing SEVIRI data with two types of data: (a) in situ and (b) obtained with the NLSST algorithm applied to Advanced Very High Resolution Radiometer (AVHRR). The field campaign was carried out over sea using a thermal radiometer. The algorithms were applied to SEVIRI images in coincidence with the field campaign and the results show an rms error lower than 0.7 K. The comparison …

RadiometerMeteorologyAdvanced very-high-resolution radiometerNon lineariteNonlinear algorithmsWRSADLIB-ART-2523Sea surface temperatureGeneral Earth and Planetary SciencesEnvironmental scienceSplit windowRoot-mean-square deviationAlgorithmField campaignRemote sensingInternational Journal of Remote Sensing
researchProduct

Comparison of stereo vision techniques for cloud-top height retrieval

2007

This paper presents an ongoing study for the estimation of the cloud-top height by using only geometrical methods. In agreement with some recent studies showing that it is possible to achieve reliable height estimations not only with the classical methods based on radiative transfer, this article includes a comparison of performances of a selected set of vision algorithms devoted to extract dense disparity maps or motion fields from Infra Red stereo image pairs. This collection includes both area-based techniques and an optical flow-based method and the comparison is accomplished by using a set of cloudy scenes selected from the Along-Track Scanning Radiometer (ATSR2) database. The first gr…

RadiometerSettore INF/01 - Informaticabusiness.industryCloud topComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONOptical flowSet (abstract data type)GeographyStereopsisRadiative transferCloud-top height multi view stereo matching algorithms satellite infra red images optical flow.Computer visionArtificial intelligencebusinessVision algorithmsComputer stereo visionRemote sensing
researchProduct