Search results for "Alignment"
showing 10 items of 627 documents
Orientation Aids for Mobile Maps
2015
Using mobile maps to represent urban, work, or entertainment environments offers new possibilities to plan and carry out tasks. One potentially critical problem in mobile map usage is the misalignment between the user's frame of reference and the frame of reference of the map. In the experiment reported here, three different ‘orientation aids’ were tested in the context of restricted space, such as a large factory hall. The aim of the study was to find out how user interface design can help the user mentally align misaligned frames of reference for efficient mobile map use. The results of the experiment (N = 12) suggest using a ‘you are here’ marker and landmark highlighting, while canonica…
Misalignment of Spectral Data: Constrained Optimization in a Functional Data Analysis Framework
2022
Across several branches of sciences, a large number of applications involves data represented as functions and curves, for which functional data analysis can play a central role in solving a variety of problem formulations. With some thecnologies, the obtained data are spectra containing a vast amount of information concerning the composition of a sample: in order to infer the chemical composition of the materials from spectra, functional data analysis offers a valuable mean for characterizing the spectral response through identification of peaks position and intensity. The collection of data from different measurement may exhibit similar peak pattern but display misalignment in their peaks…
Calibration of the underground muon detector of the Pierre Auger Observatory
2021
To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 $\mathrm{m^2}$-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m$^2$ close to the intersection of the shower axis with the ground to much less than one per m$^2$ when far away, the necessary bro…
H2-M polymorphism in mice susceptible to collagen-induced arthritis involves the peptide binding groove.
1996
The ability to develop type II collagen (CII)-induced arthritis (CIA) in mice is associated with the major histocompatibilityI-A gene and with as yet poorly defined regulatory molecules of the major histocompatibility complex (MHC) class II antigen processing and presentation pathway. H2-M molecules are thought to be involved in the loading of antigenic peptides into the MHC class II binding cleft. We sequencedH2-Ma, H2-Mb1, andH2-Mb2 genes from CIA-susceptible and-resistant mouse strains and identified four differentMa andMb2 alleles and three differentMb1 alleles defined by polymorphic residues within the predicted peptide binding groove. Most CIA-resistant mouse strains share commonMa, M…
Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: …
2020
The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomogra…
Patient Specific Instrumentation for Total Knee Arthroplasty: a Literature Review
2014
During the past decade, total knee arthroplasty (TKA) has been markedly increased. Recently, patient-specific custom cutting guides have been commercially introduced in order to achieve an accurate component alignment during TKA. In fact, these cutting blocks are specific to a patient’s knee anatomy and should help the surgeons to perform bone cuts, reducing the complexity of conventional alignment and sizing tools. Nevertheless, there are critical arguments against patient-specific cutting guides for routine use, such as poor evidence and higher costs. Additionally, there are still no mild and long-term results available that describe the clinical outcomes following patient-specific instru…
Comparison of Postoperative Coronal Leg Alignment in Customized Individually Made and Conventional Total Knee Arthroplasty
2021
Neutral coronal leg alignment is known to be important for postoperative outcome in total knee arthroplasty (TKA). Customized individually made implants (CIM) instrumented with patient-specific cutting guides are an innovation aiming to increase the precision and reliability of implant positioning and reconstruction of leg alignment. We aimed to compare reconstruction of the hip–knee–ankle angle (HKA) of the novel CIM system iTotal™ CR G2 (ConforMIS Inc.) to a matched cohort of the off-the-shelf (OTS) knee replacement system Vanguard™ CR (Zimmer Biomet). Retrospective analysis of postoperative coronal full-leg weight-bearing radiographs of 562 TKA (283 CIM TKA, 279 OTS TKA) was conducted. V…
Negative and positive Kerr nonlinearity of air calibrated with transient molecular alignment
2009
Talk given by O. Faucher; International audience; Nonlinear electronic Kerr index of the major air constituents has been measured up to high order terms using transient molecular alignment as a reference. Sign reversal associated to negative nonlinearity is observed above a pulse intensity of 26 TW/cm^.2
Alignment of linear molecules by short duration laser pulses
2005
Alignment of linear molecules is efficiently induced by strong linearly polarized laser pulses. In the case of short pulses with respect to molecular rotation, periodic alignment appears in field-free conditions after the extinction of the field. This manuscript presents three techniques where the value of allows to quantify alignment without molecular dissociation nor additional alignment. They use a weak time-delayed probe pulse which experiences the optical properties of an aligned sample and shows modification of its characteristics. The first of them measures a depolarization due to the birefringence of the sample. The second one is based on the defocusing produced by the spatial distr…
Characterization and transcription studies of a phytochelatin synthase gene from the solitary tunicate Ciona intestinalis exposed to cadmium.
2014
The major thiol-containing molecules involved in controlling the level of intracellular ROS in eukaryotes, acting as a nonenzymatic detoxification system, are metallothioneins (MTs), glutathione (GSH) and phytochelatins (PCs). Both MTs and GSH are well-known in the animal kingdom. PC was considered a prerogative of the plant kingdom but, in 2001, a phytochelatin synthase (PCS) gene was described in the nematode Caenorhabditis elegans; additional genes encoding this enzyme were later described in the earthworm Eisenia fetida and in the parasitic nematode Schistosoma mansoni but scanty data are available, up to now, for Deuterostomes. Here, we describe the molecular characteristics and transc…