Search results for "Alkylbenzenes"

showing 9 items of 9 documents

Anionic-anionic asymmetric tandem reactions: one-pot synthesis of optically pure fluorinated indolines from 2-p-tolylsulfinyl alkylbenzenes.

2008

Anionsgamma-sulfinyl carbanionsIndolesTandemChemistryindolinesOne-pot synthesisasymmetric synthesisEnantioselective synthesisBenzeneStereoisomerismGeneral ChemistryGeneral MedicineFluorineCatalysisfluorine chemistrychemistry.chemical_compoundIndolineOrganic chemistryAlkylbenzenesAngewandte Chemie (International ed. in English)
researchProduct

Effect of sodium dodecyl sulphate and Brij-35 on the analysis of sulphonamides in physiological samples using direct injection and acetonitrile gradi…

2016

Micellar liquid chromatography (MLC) is a reversed-phase (RP) mode, which often does not require gradient elution, since the peaks of mixtures of compounds within a large range of polarities appear more evenly distributed in the chromatograms of isocratic elution, giving rise to a “gradient effect”. However, the use of a gradient of organic solvent may still be convenient to shorten the total analysis time. This work compares the separation of 15 sulphonamides using conventional hydro-organic RPLC and MLC with the surfactants sodium dodecyl sulphate (SDS) and Brij-35, and both isocratic and gradient elution with acetonitrile. The observed behaviour is rationalized attending to the interacti…

Isocratic elutionChromatographyChemistryElutionGeneral Chemical EngineeringSodium010401 analytical chemistryGeneral EngineeringAnalytical chemistrychemistry.chemical_element010402 general chemistry01 natural sciences0104 chemical sciencesAnalytical Chemistrychemistry.chemical_compoundStationary phaseMicellar liquid chromatographyPhase (matter)AlkylbenzenesAcetonitrileAnalytical Methods
researchProduct

Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography

2017

[EN] In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch®), or mixtures of H2O2 and H2SO4, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification…

Monolithic HPLC columnMicrobore column02 engineering and technology01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundSurface modificationQUIMICA ANALITICAEnvironmental ChemistryMonolith attachmentMonolithReversed-phase liquid chromatographyPolytetrafluoroethyleneSpectroscopychemistry.chemical_classificationChromatography Reverse-PhasegeographyChromatographygeography.geographical_feature_categoryPolytetrafluoroethyleneChemistry010401 analytical chemistryPolymer monolithEquipment DesignPolymer021001 nanoscience & nanotechnology0104 chemical sciencesChemical engineeringPolymerizationAttenuated total reflectionSurface modificationAlkylbenzenes0210 nano-technologyAnalytica Chimica Acta
researchProduct

Benzyl ions from 1,1-(2,2′-dimethoxyphenyl)-substituted 2-methylpropanes under electron ionization

2006

The electron ionization (EI)-induced fragmentations of a series of 1,1-(2,2'-dimethoxyphenyl)-substituted 2-methylpropanes (1-20) in both 70 eV and mass-analyzed ion kinetic energy (MIKE) spectra have been investigated. The EI-MS spectra of these compounds are characterized by the presence of abundant benzyl ions. These ions result from competitive hydrogen migration from the 2- and 2'-methoxy groups on the carbenium center of the diphenylmethyl cations formed by benzylic cleavage of the molecular ions. The relative abundances of the benzyl ions arising from such competitive processes are discussed and rationalized. The steric effect of the 3- or 3'-substituents is the main discriminating f…

Steric effectsSpectrometry Mass Electrospray IonizationHydrogenStereochemistrychemistry.chemical_elementKinetic energyMedicinal chemistrySpectral lineAnalytical ChemistryIonPropaneBenzyl CompoundsSpectroscopyElectron ionizationCARBON DOUBLE REARRANGEMENTMASS-SPECTRAHydrocarbons HalogenatedOrganic ChemistryCleavage (crystal)HYDROGEN-CARBONDIMETHOXY AROMATIC-COMPOUNDSSPECTROMETRYchemistryALKYLBENZENESSUBSTITUTED DIPHENYLMETHYL CATIONSHydrogenRapid Communications in Mass Spectrometry
researchProduct

Photo-polymerized lauryl methacrylate monolithic columns for CEC using lauroyl peroxide as initiator

2009

Lauryl methacrylate (LMA)-ester based monolithic columns photo-polymerized using lauroyl peroxide (LPO) as initiator were prepared, and their morphological and CEC properties were studied. The composition of the polymerization mixture (i.e. ratios of monomers/porogenic solvents, 1,4-butanediol/1-propanol and LMA/crosslinker) was optimized. The morphological and chromatographic properties of LMA columns were evaluated by means of SEM pictures and van Deemter plots of PAHs, respectively. The polymerization mixture selected as optimal provided a fast separation of a mixture of PAHs with excellent efficiencies (minimum plate heights of 8.9-11.1 μm). Satisfactory column-to-column (RS D < 4.5%) a…

Van Deemter equationLipid PeroxidesChromatographyResolution (mass spectrometry)PhotochemistryClinical BiochemistryReproducibility of ResultsLauroyl peroxideBiochemistryAnalytical Chemistrychemistry.chemical_compoundMonomerchemistryPolymerizationCapillary ElectrochromatographyNitrilesMicroscopy Electron ScanningMethacrylatesAlkylbenzenesPolycyclic Aromatic HydrocarbonsLauryl methacrylateELECTROPHORESIS
researchProduct

Life-time studies with capillary electrochromatography columns operated under different conditions.

2000

A test system has been established to permit the monitoring of the life-time performance of several reversed- phase capillary electrochromatography (CEC) columns. The retention factors, k(cec), peak symmetry coefficients, lambda(sym), and column efficiencies, N, of three neutral n-alkylbenzene analytes, namely ethyl-, n-butyl- and n-pentylbenzenes, were determined for Hypersil 3 microm n-octylsilica and n-octadecylsilica packed into CEC capillary columns of 100 microm I.D., with a packed length of 250 mm, and a total length of 335 mm. The performances of these CEC capillary columns were examined for a variety of eluents with pH values ranging between pH 2.0 - 8.0, similar to those employed …

chemistry.chemical_classificationCapillary electrochromatographyChromatographyCapillary actionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyHydrocarbonchemistryElectrochromatographyAlkylbenzenesTheoretical plateChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Modelling retention and peak shape of small polar solutes analysed by nano-HPLC using methacrylate-based monolithic columns.

2019

Abstract The development of methacrylate-based monolithic columns was studied for the separation of pharmaceutical hydrophilic compounds in nano-liquid chromatography. The selected polymerisation mixture consisted of 7.5% hexyl methacrylate, 4.5% methacrylic acid and 18.0% ethylene dimethacrylate (w/w), in a binary porogenic solvent (35:35 w/w 1-propanol/1,4-butanediol). The polymer synthesised with this mixture has a good permeability, not excessive back-pressure, and reasonable retention times for polar and non-polar solutes. Monolithic columns (12 cm total capillary length, 100 μm i.d.), prepared with this mixture, were able to produce hydrogen bonding and electrostatic interactions, giv…

chemistry.chemical_classificationChromatography010401 analytical chemistry02 engineering and technologyPolymer021001 nanoscience & nanotechnologyMethacrylate01 natural sciencesBiochemistryHigh-performance liquid chromatography0104 chemical sciencesAnalytical ChemistrySolventchemistry.chemical_compoundchemistryMethacrylic acidEnvironmental ChemistryAlkylbenzenesParticle size0210 nano-technologySelectivitySpectroscopyAnalytica chimica acta
researchProduct

Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance …

1999

In this paper we report on the results of a comparative study on the performance of Purospher RP 18e, 5 μm, columns and prototypes of monolithic columns named SilicaROD from Merck, Darmstadt, Germany. The studies were performed on HPLC equipment with minimum extra column contribution. The plate height linear velocity dependency of the Purospher RP 18e column showed a minimum of H of about 10–15 μm at a linear velocity of 1 mm/s. The H versus u curves of the monolithic columns followed the same course. Yet, the curves remained flat up to a linear velocity of about 7 mm/s, where the Purospher RP 18e column could not be operated anymore due to the extremely high back-pressure. In conclusion th…

chemistry.chemical_compoundChromatographyChemistryDrop (liquid)Organic ChemistryAnalytical chemistryAlkylbenzenesGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryJournal of Chromatography A
researchProduct

ChemInform Abstract: Anionic-Anionic Asymmetric Tandem Reactions: One-Pot Synthesis of Optically Pure Fluorinated Indolines from 2-p-Tolylsulfinyl Al…

2009

chemistry.chemical_compoundTandemchemistryOne-pot synthesisOrganic chemistryAlkylbenzenesGeneral MedicineChemInform
researchProduct