Search results for "Analyte"
showing 10 items of 303 documents
A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations
2015
An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…
A new selective method for dimethylamine in water analysis by liquid chromatography using solid-phase microextraction and two-stage derivatization wi…
2005
Abstract A new method is presented for the determination of DMA in water as its 9-fluorenylmethyl chloroformate (FMOC) derivative using solid-phase microextraction (SPME) and liquid chromatography. The method is based on the employment of SPME fibres coated with carbowax-templated resin (CW-TR) for analyte extraction and derivatization. The fibres were successively immersed in the samples, in a solution of o -phthalaldialdehyde and N -acethyl- l -cysteine (OPA–NAC) and finally, in a solution of FMOC. OPA–NAC reacted on the fibre with possible primary aliphatic amines present in the samples, particularly with PA which is a direct interferent in the determination of DMA with FMOC. In such a w…
Ionic liquid-based single-drop microextraction followed by liquid chromatography-ultraviolet spectrophotometry detection to determine typical UV filt…
2009
Abstract A user-friendly and inexpensive ionic liquid-based single-drop microextraction (IL-SDME) procedure has been developed to preconcentrate trace amounts of six typical UV filters extensively used in cosmetic products (i.e., 2-hydroxy-4-methoxybenzophenone, isoamyl 4-methoxycinnamate, 3-(4′-methylbenzylidene)camphor, 2-ethylhexyl 2-cyano-3,3-diphenylacrylate, 2-ethylhexyl 4-dimethylaminobenzoate and 2-ethylhexyl 4-methoxycinnamate) from surface water samples prior to analysis by liquid chromatography-ultraviolet spectrophotometry detection (LC-UV). A two-stage multivariate optimization approach was developed by means of a Plackett–Burman design for screening and selecting the significa…
Cyclam-functionalized silica-modified electrodes for selective determination of Cu(II)
2009
Cyclam derivatives have been grafted via 1, 2 or 4 silylated arms to the surface of mesoporous silica and the resulting materials have been incorporated into carbon paste electrodes and applied to the preconcentration electroanalysis of Cu(II). Sensitive and selective detection of the target analyte was achieved owing to the attractive binding properties of this macrocyclic ligand towards Cu(II) species. Various parameters likely to affect the preconcentration and detection steps have been studied, including pH of the accumulation medium, composition of the detection solution, structure and composition of the adsorbent, accumulation time, or presence of potentially interfering species. In p…
Fast enantiomeric separation of uniconazole and diniconazole by electrokinetic chromatography using an anionic cyclodextrin: application to the deter…
2000
The enantiomeric resolution of the fungicides uniconazole and diniconazole was performed using electrokinetic chromatography with cyclodextrins as pseudostationary phase (CD-EKC). A systematic evaluation of several chiral selectors was made. The anionic derivative carboxymethylated-gamma-cyclodextrin (CM-gamma-CD) was found to be the most appropriate for the enantioseparation of fungicides among all cyclodextrins tested. The influence of some experimental conditions such as nature and buffer pH, chiral selector concentration, and temperature on the enantiomeric separation of the compounds studied was also investigated. The use of a 50 mM phosphate buffer (pH 6.5) containing 5 mM CM-gamma-CD…
DNA quantification approach by GE-ICP-SFMS and complementary total phosphorus determination by ICP-SFMS
2006
Quantification of DNA is still a great challenge for scientists in many fields. Here, we present the on-line coupling of gel electrophoresis (GE) and inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) for quantitative purposes. GE conditions are chosen for optimised separations depending on the target analyte composition in terms of DNA chain length. In particular, agarose concentrations are varied in the range 0.6–2.2%, which corresponds to a separation range of DNA from 100 base pairs (bp) to genomic DNA (approximately 3 Mbp). Separated DNA compounds are directly transported at a flow rate of 100 μL min−1 to a Micromist nebuliser which is followed by ICP-SFMS with 31P de…
Speichel als Matrix für das Humanbiomonitoring in der Arbeits- und Umweltmedizin [Biomonitoring Methods in German Language, 2015]
2016
Saliva as a matrix for human biomonitoring in occupational and environmental medicine Purpose: Human biomonitoring (HBM) implies the assessment of internal exposure to hazardous substances by measuring the substances, their metabolites or reaction products, as well as effect parameters in human body fluids. Along with blood, plasma and urine, saliva is of increasing interest as an alternative matrix for HBM. Methods: This paper reviews studies that measure salivary background levels of hazardous substances, elevated levels after environmental or occupational exposure, as well as references which deal with physiological and toxicokinetic behaviour of saliva and salivary parameters, respectiv…
A tailor-made nucleoside-based colourimetric probe of formic acid
2014
A ratiometric, specific probe of formic acid has been developed. It is based on intermolecular nucleobase-pairing of inosine-capped plasmonic nanoparticles to form nucleoside channels, which are destabilised by the analyte.
Micellar electrokinetic capillary chromatography for therapeutic drug monitoring of carbamazepine and its main metabolites.
1998
In carbamazepine (CBZ) therapy the concomitant monitoring of concentrations of CBZ and its metabolites is strictly recommended, primarily to avoid toxic side effects. Currently, clinical routine monitoring of CBZ is accomplished by high-performance liquid chromatography or immunological methods. In this study a micellar electrokinetic capillary chromatographic (MECC) method was developed for routine drug monitoring of CBZ and its main metabolites, carbamazepine 10,11-diol and carbamazepine 10,11-epoxide, in human serum or plasma samples. The MECC method enabled baseline separation of all analytes within 2.5 min. The assay revealed sufficient precision and sensitivity and the results of eith…
A Post-Labeling Approach for the Characterization and Quantification of RNA Modifications Based on Site-Directed Cleavage by DNAzymes
2011
Deoxyribozymes or DNAzymes are small DNA molecules with catalytic activity originating from in vitro selection experiments. Variants of the two most popular DNAzymes with RNase activity, the 10-23 DNAzyme and the 8-17 DNAzyme, promote efficient in vitro cleavage of the phosphodiester bond in at least 11 out of 16 possible dinucleotide permutations. Judicious choice of the sequences flanking the active core of the DNAzymes permits to direct cleavage activity with high sequence specificity. Here, the harnessing of these features for the analysis of RNA nucleotide modifications by a post-labeling approach is described in detail. DNAzymes are designed such that RNase cleavage is directed precis…