Search results for "Analyte"
showing 10 items of 303 documents
An investigation of the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid in authentic urine samples.
2004
Preanalytical stability of a drug and its major metabolites is an important consideration in pharmacokinetic studies or whenever the analyte pattern is used to estimate drug habits. Firstly, the stability of free and glucuronidated 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH, THCCOOglu) in authentic urine samples was investigated. Random urine samples of cannabis users (n = 38) were stored at -20, 4, and 20 degrees C up to 15 days and up to 5 days at 40 degrees C, and alterations of the analyte pattern during storage were followed by liquid chromatography-tandem mass spectrometry. Secondly, the influence of pH (range 5.0-8.0) on the stability of the analytes was studied us…
Hyperbolic subtraction method: Determination of the concentration of an analyte in the presence of an unknown interferent via spectral data.
2018
A theoretical model to determine the concentration of an analyte in the presence of unknown interferents using spectral-type data is described. The method involves absorbance measurements at three wavelengths and the calculation of specific absorbances yielding a hyperbolic relationship between absorbance ratios and analyte concentrations. The concentration of the analyte of known spectrum can be determined in the presence of an interferent or mixture of interferents of unknown concentration(s) and spectra can be determined combining data for different sets of wavelengths. Application to indigo and isatin solutions in DMSO related to the so-called Maya blue problem is reported as an illustr…
Generation of TCR-Engineered T Cells and Their Use To Control the Performance of T Cell Assays
2015
Abstract The systematic assessment of the human immune system bears huge potential to guide rational development of novel immunotherapies and clinical decision making. Multiple assays to monitor the quantity, phenotype, and function of Ag-specific T cells are commonly used to unravel patients’ immune signatures in various disease settings and during therapeutic interventions. When compared with tests measuring soluble analytes, cellular immune assays have a higher variation, which is a major technical factor limiting their broad adoption in clinical immunology. The key solution may arise from continuous control of assay performance using TCR-engineered reference samples. We developed a simp…
The H-point and generalized H-point standard additions methods for flow injection procedures.
1997
This paper establishes the fundamentals of the H-point standard additions method (HPSAM) and generalized H-point standard additions method (GHPSAM) in the flow injection technique. Two kinds of analytical signals can be employed, FIA peaks and spectra. Different analytical problems have been studied: determinations of one analyte in the presence or absence of matrix effect when different blank features are present, and determination of two analytes in the presence of blank bias error affecting the development of one of them. The determination of chloride with mercury thiocyanate which presents a matrix effect, and the determinations of calcium and/or magnesium with arsenazo III are examined…
Observation of interaction forces by investigation of the influence of eluent additives on the retention behavior of aqueous nanoparticle dispersions…
2020
The investigation and subsequent understanding of the interactions of nanomaterials with components of their surrounding media is important to be able to evaluate both potential use cases as well as potential risks for human health and for the environment. To investigate such interactions, asymmetrical flow field-flow fractionation (AF4) is an interesting analytical tool. This statement grounds on the fact that interactions of the analyte with the membrane and with components of the eluent are crucial for the retention behavior of the analyte within the field-flow fractionation (FFF) channel. Therefore, the investigation of the retention behavior provides an insight in the nature of the int…
Determination of biochemical parameters in human serum by near-infrared spectroscopy
2014
NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipopr…
Wide-range screening of banned veterinary drugs in urine by ultra high liquid chromatography coupled to high-resolution mass spectrometry
2012
In this work, an ultra high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS) methodology is proposed for the multi-class multi-residue screening of banned and unauthorized veterinary drugs in bovine urine, using an Orbitrap Exactive™ analyzer working at a resolving power of 50,000 FWHM in full scan, both in positive and negative mode. The method currently covers 87 analytes belonging to different families such as steroid hormones, β-agonists, resorcylic acid lactones (RAL), stilbens, tranquillizers, nitroimidazoles, corticosteroids, NSAIDs, amphenicoles, thyreostatics and other substances such as dapsone. A database including the elemental composition, the po…
Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.
2017
A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8 μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology.
Electrochemical pH Control at Gold Nanowires
2018
In this work, interdigitated arrays of nanowire electrodes are used with one array acting as the working electrode while the other is used to generate the required protons. Finite element simulations of the pH control electrodes were performed to provide insight on the generation and subsequent diffusion of protons. This informed the inter-tine spacing of the electrodes used.. This electrochemical pH control method was then used to enable the detection of analytes of interest.
A taylor series model to evaluate the interelemental effects in X-ray fluorescence analysis, applied to the iron-zirconium-diluent system
1995
A semi-empirical model has been developed to quantify the interelemental effects in X-ray fluorescence analysis. The measured X-ray fluorescence intensity has been expressed as a function of the different fluorescence elements composing the sample. this complex function has become an operative function via a Taylor series development. An explication has been given for the significance of the different terms of the series. These terms respond to mathematical functions known as characteristic functions for each chemical system. A parameter (B) has been defined which makes it possible to quantify the influence of the interelemental effect as a function of the analyte concentration (C) and that…