Search results for "Analyte"

showing 10 items of 303 documents

ChemInform Abstract: Supramolecular Chemical Sensors Based on Pyrene Monomer-Excimer Dual Luminescence.

2011

The past ten years have seen a spectacular development of chemical sensors based on the monomer-excimer dual luminescence of aromatic systems, such as pyrene. Either in the form of integrated or multicomponent molecular devices these chemosensors have been attracting a high interest above all because of their unique ratiometric properties. This review will focus on the latter systems, which can be classified into two classes: Firstly, the assembly of receptor-effector conjugates is triggerred by the analyte of interest. As a result, the sensor shows monomer to excimer fluorescence switching upon substrate binding. Secondly, the supramolecular assembly that constitutes the sensor is perturbe…

Analytechemistry.chemical_compoundMonomerchemistrySupramolecular chemistryPyreneGeneral MedicineLuminescencePhotochemistryExcimerFluorescenceSupramolecular assemblyChemInform
researchProduct

Immuno-SLM—a combined sample handling and analytical technique

2004

Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted ac…

AnalytefluoresceinCalibration curveImmunologyAnalytical chemistryFresh WaterAntibodiesAntigen-Antibody ReactionsBeveragesMatrix (chemical analysis)Tap waterImmunology and AllergyImmunoassayDetection limitOrange juiceiImmuno extractionChromatographyrestricted accessHerbicidesChemistryElutiontap waterExtraction (chemistry)Membranes Artificialriver watersupported liquid membrane extractionorange juiceAtrazineWater Pollutants ChemicalJournal of Immunological Methods
researchProduct

Curve resolution procedure for isolating the spectra of unknown interferences from the sample spectrum in analyte determinations

1998

The method described is based on the selection of a wavelength in the sample spectrum that is called ‘reference wavelength’, all measured wavelengths are previously assayed in order to select this reference wavelength. Several wavelengths can be used as the reference. The interferent spectrum is calculated as a function of the interferent absorbance at this wavelength, making use of the ratio between the absorbance of the analyte at the selected wavelength and at every measured wavelength. The proposed methodology can estimate the unknown interferent spectrum from the sample and pure analyte spectra. As a quality guarantee of the estimated spectrum, its shape is also estimated in spiked sam…

Analytegenetic structuresResolution (mass spectrometry)ChemistrySample (material)Analytical chemistryPhysics::OpticsBiochemistrySpectral lineAnalytical ChemistryChemometricsAbsorbanceWavelengthStandard additionElectrochemistryEnvironmental Chemistrysense organsSpectroscopyThe Analyst
researchProduct

Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold

2021

Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…

AnalytemassaspektrometriaMaterials sciencetutkimuslaitteetAnalytical chemistryMass spectrometry01 natural sciencesSignalAnalytical ChemistryIonoptimointi0103 physical sciencesInstrumentationInductively coupled plasma mass spectrometrymatrix effectSpectroscopy010302 applied physicsDetection limit010401 analytical chemistryAtomic and Molecular Physics and Optics0104 chemical sciencesSpICP-MSParticleinstrumental parametersnanoparticlesnanohiukkasetParticle sizeoptimization
researchProduct

Carbon nanotube-protein carriers enhance size-dependent self-adjuvant antibody response to haptens

2013

Carbon nanotubes (CNTs) are nanomaterials with interesting emerging applications. Their properties make CNTs excellent candidates for use as new nanovehicles in drug delivery, immunization and diagnostics. In the current study, we assessed the immune-response-amplifying properties of CNTs to haptens by using azoxystrobin, the first developed strobilurin fungicide, asamodel analyte. Anazoxystrobin derivative bearingacarboxylated spacer arm (hapten AZc6) was covalently coupled to bovine serum albumin (BSA), and the resulting BSA-AZc6 conjugate was covalently linked to four functionalized CNTs of different shapes and sizes, varying in diameter and length. These four types of CNT-based construc…

Analytemedicine.medical_treatmentAzoxystrobinFreund's AdjuvantAntigen deliveryCarbon nanotubesPharmaceutical ScienceAntibodiesBiomaterialsMicechemistry.chemical_compoundMicroscopy Electron TransmissionmedicineAnimalsOrganic chemistryBovine serum albuminDrug CarriersMice Inbred BALB CbiologyNanotubes CarbonChemistrySerum Albumin BovineStrobilurinsFungicides IndustrialPyrimidinesAzoxystrobinImmunoglobulin GDrug deliverybiology.proteinBiophysicsMethacrylatesFemaleImmunizationRabbitsAntibodyHaptensAdjuvantHaptenConjugate
researchProduct

Surface Pretreatment Boosts the Performance of Supramolecular Affinity Materials on Quartz Crystal Microbalances for Sensor Applications

2013

A Teflon-like coating is the key for the boost in sensitivity of quartz microbalances for the tracing of airborne analytes. Since the undesired signals for the interfering compounds are suppressed and the ones for the targeted compounds (e.g., peroxide explosives) are enhanced, the PCA output is improved.

Analytetechnology industry and agricultureSupramolecular chemistryNanotechnologyrespiratory systemengineering.materialcomplex mixturesSensitivity (explosives)PeroxideAnalytical ChemistryCrystalchemistry.chemical_compoundchemistryCoatingengineeringQuartzAnalytical Chemistry
researchProduct

Modified locally weighted—Partial least squares regression improving clinical predictions from infrared spectra of human serum samples

2012

Locally weighted partial least squares regression (LW-PLSR) has been applied to the determination of four clinical parameters in human serum samples (total protein, triglyceride, glucose and urea contents) by Fourier transform infrared (FTIR) spectroscopy. Classical LW-PLSR models were constructed using different spectral regions. For the selection of parameters by LW-PLSR modeling, a multi-parametric study was carried out employing the minimum root-mean square error of cross validation (RMSCV) as objective function. In order to overcome the effect of strong matrix interferences on the predictive accuracy of LW-PLSR models, this work focuses on sample selection. Accordingly, a novel strateg…

Blood GlucoseAnalyteChemistryBlood ProteinsCross-validationAnalytical ChemistryChemometricsMatrix (chemical analysis)symbols.namesakeFourier transformSpectroscopy Fourier Transform InfraredPartial least squares regressionPrincipal component analysisStatisticssymbolsHumansUreaLeast-Squares AnalysisFourier transform infrared spectroscopyBiological systemTriglyceridesTalanta
researchProduct

Low light level in vitro monitoring of cellular and antigen-antibody reactions using a photon detection camera system — New perspectives for clinical…

1990

This article briefly describes the use of a photon counting system (ARGUS-100) in the detection of low levels of light. The ARGUS-100 was used in determining ATP in cell sections from tumor tissues and in measuring a luminescence-enhanced immunoluminometric assay, using ferritin as the analyte, based on the luminol-peroxide-4-iodophenol reaction with peroxidase as the enzyme. The aim is not so much the presentation of data, but rather to show the potentials of the photon counting camera in increasing our knowledge of the cellular and subcellular levels, as well as lowering the detection limits in already sensitive systems, such as immunoassays.

Blood GlucoseAnalyteVideo RecordingNanotechnologyAdenocarcinomaCell Linelaw.inventionAntigen-Antibody ReactionsImmunoenzyme TechniquesAdenosine TriphosphateMicrocomputersComputer SystemslawRhabdomyosarcomaDrug DiscoveryTumor Cells CulturedAnimalsHumansBioluminescenceLactic AcidGenetics (clinical)ChemiluminescenceDetection limitChemistrySignal Processing Computer-AssistedGeneral MedicineIn vitroPhoton countingRatsLow light levelClinical diagnosisLuminescent MeasurementsLactatesBiophysicsMolecular MedicineKlinische Wochenschrift
researchProduct

Improving sensitivity in simultaneous determination of copper carboxylates by nonaqueous capillary electrophoresis

2005

Abstract A new method of nonaqueous capillary electrophoresis (NACE) with UV spectrophotometric detection was developed and optimized for the simultaneous determination of seven carboxylates (trans-1,2-diaminocyclohexane-N,N,N′,N′-tetraacetic acid (CDTA), diethylenetriaminepentaacetic acid (DTPA), ethylenediaminetetraacetic acid (EDTA), N-(2-hydroxyethyl)ethylenediamine-N,N′,N′-triacetic acid (HEDTA), nitrilotriacetic acid (NTA), 1,3-diaminopropane-N,N,N′,N′-tetraacetic acid (PDTA) and triethylenetetraaminehexaacetic acid (TTHA)) as copper complexes. The method development was carried out by using a fused silica capillary. Background electrolyte (BGE) was optimized and the best separation a…

BromidesAnalytePotassium CompoundsCarboxylic Acidschemistry.chemical_elementEthylenediaminetetraacetic acidBuffersSensitivity and SpecificityBiochemistryAnalytical ChemistryElectrolyteschemistry.chemical_compoundCapillary electrophoresisOrganometallic CompoundsChelationCarboxylateEdetic AcidChelating AgentsChromatographyFormamidesChemistryPotassium bromideOrganic ChemistryNitrilotriacetic acidElectrophoresis CapillaryGeneral MedicineHydrogen-Ion ConcentrationCopperCalibrationCopperWater Pollutants ChemicalJournal of Chromatography A
researchProduct

Solid-Phase Extraction and Clean-Up Procedures in Pharmaceutical Analysis

2012

Solid-phase extraction (SPE) using small cartridges filled with sorbents of a small particle size has rapidly established itself as an important sample clean-up technique. It has prospered at the expense of liquid-liquid extraction (LLE), which is considered labor intensive and frequently plagued by problems, such as emulsion formation and use of large volumes of hazardous solvents. A remarkable characteristic of SPE is its easy adaptation to on-line mode by column-switching techniques; switching can be effected manually or by automated controllers. The same analyte/sorbent interactions that are exploited in liquid chromatography (LC) are of use in SPE, but particle sizes employed are great…

CartridgeAnalytechemistry.chemical_compoundMaterials scienceSorbentChromatographychemistryExtraction (chemistry)Molecularly imprinted polymerSolid phase extractionDerivatizationClean-up
researchProduct