Search results for "Analytical"

showing 10 items of 9586 documents

Complexation of Uranium by Cells and S-Layer Sheets of Bacillus sphaericus JG-A12

2005

ABSTRACT Bacillus sphaericus JG-A12 is a natural isolate recovered from a uranium mining waste pile near the town of Johanngeorgenstadt in Saxony, Germany. The cells of this strain are enveloped by a highly ordered crystalline proteinaceous surface layer (S-layer) possessing an ability to bind uranium and other heavy metals. Purified and recrystallized S-layer proteins were shown to be phosphorylated by phosphoprotein-specific staining, inductive coupled plasma mass spectrometry analysis, and a colorimetric method. We used extended X-ray absorption fine-structure (EXAFS) spectroscopy to determine the structural parameters of the uranium complexes formed by purified and recrystallized S-laye…

inorganic chemicalsDenticityAnalytical chemistrychemistry.chemical_elementBacillusMass spectrometryApplied Microbiology and BiotechnologyBacillus sphaericusMiningchemistry.chemical_compoundBacterial ProteinsMicroscopy Electron TransmissionMembrane GlycoproteinsEcologybiologyExtended X-ray absorption fine structureSpectrum AnalysisX-RaysPhosphorusUraniumPhosphoproteinsbiology.organism_classificationPhosphateGeomicrobiologychemistryTransmission electron microscopyUraniumAbsorption (chemistry)Food ScienceBiotechnologyNuclear chemistryApplied and Environmental Microbiology
researchProduct

Determination of selenium, zinc and cadmium in antidandruff shampoos by atomic spectrometry after microwave assisted sample digestion

2000

Microwave assisted pre-treatments for atomic spectrometric determination (inductive coupled plasma-optical emission spectrometry, ICP-OES or flame atomic absorption spectrometry, FAAS) of metallic elements, usually present in antidandruff shampoos, are proposed. They are based on the digestion of the sample with HNO(3) into a closed reactor, which is irradiated at 800 W for a few minutes. Selenium was determined by ICP-OES. The limit of detection was 0.11 mg l(-1); the relative standard deviation (R.S.D.) for the selenium content in the samples was in the 0.6-3.6% range. The results obtained were in agreement with the label contents and the recovery of the proposed method was in the 100-106…

inorganic chemicalsDetection limitCadmiumChromatographyMicrowave ovenAnalytical chemistrychemistry.chemical_elementZincAnalytical Chemistrylaw.inventionchemistryAshinglawInductively coupled plasma atomic emission spectroscopyAtomic absorption spectroscopySeleniumTalanta
researchProduct

Electrothermal Atomic Absorption Determination of Chromium in Sediments

1999

Abstract An electrothermal atomic absorption spectrometric method has been developed to determine total chromium concentration in natural sediment samples. Samples were mineralized by dry ashing at 550°C and fused at 1100°C for 30 min with lithium metaborate. Dissolved samples were injected in graphite tubes, mineralized at 1100°C, and atomized at 2600°C. Standard addition calibration made unnecessary the use of chemical modifiers. The method provided a limit of detection from 23 to 45 ng liter −1 . The relative standard deviation for chromium determination was between 3 and 14%. Results obtained for a standard reference material agree well with the certified value. A series of natural samp…

inorganic chemicalsDetection limitChemistryAnalytical chemistrychemistry.chemical_elementAnalytical Chemistrylaw.inventionLithium metaborateChromiumchemistry.chemical_compoundAshinglawStandard additionNeutron activation analysisAtomic absorption spectroscopySpectroscopyNeutron activationMicrochemical Journal
researchProduct

A new simple chromo-fluorogenic probe for NO2 detection in air.

2015

[EN] A new chromo-fluorogenic probe, consisting of a biphenyl derivative containing both a silylbenzyl ether and a N,N-dimethylamino group, for NO2 detection in the gas phase has been developed. A clear colour change from colourless to yellow together with an emission quenching was observed when the probe reacted with NO2. A limit of detection to the naked eye of about 0.1 ppm was determined and the system was successfully applied to the detection of NO2 in realistic atmospheric conditions.

inorganic chemicalsGas phase reactionsAnalytical chemistryEtherPhotochemistryNO2Nitric Oxidecomplex mixturesCatalysisGas phasechemistry.chemical_compoundQUIMICA ORGANICAChromogenic detectionFluorescent DyesDetection limitBiphenylEmission quenchingSIMPLE (dark matter experiment)Molecular StructureSensorsAirOrganic ChemistryQUIMICA INORGANICAGeneral Chemistryrespiratory systemchemistryChromogenic CompoundsNaked eyeDerivative (chemistry)Chemistry (Weinheim an der Bergstrasse, Germany)
researchProduct

Surface enhanced Raman scattering of silver sensitized cobalt nanoparticles in metal–dielectric nanocomposites

2008

We report the preparation of a new type of nanocomposite containing cobalt and silver nanoparticles organized in parallel layers with a well controlled separation. This arrangement allows the observation of an enhanced low-frequency Raman signal at the vibration frequency of cobalt nanoparticles excited through the surface plasmons of silver nanoparticles. Numerical simulations of the electric field confirm the emergence of hot spots when the separation between silver and cobalt nanoparticles is small enough. © IOP Publishing Ltd.

inorganic chemicalsMaterials scienceAnalytical chemistry[ PHYS.COND.CM-MS ] Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]chemistry.chemical_elementNanoparticleNanoprobeBioengineering02 engineering and technology01 natural sciencesSilver nanoparticlesymbols.namesake0103 physical sciencesGeneral Materials ScienceElectrical and Electronic Engineering010306 general physicsNanocompositeMechanical EngineeringPhysicsSurface plasmonGeneral Chemistry021001 nanoscience & nanotechnologychemistryChemical engineeringMechanics of Materialssymbols[PHYS.COND.CM-MS]Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]0210 nano-technologyRaman spectroscopyCobaltRaman scattering
researchProduct

Influence of Ge doping level on the EPR signal of Ge(1), Ge(2) and E'Ge defects in Ge-doped silica

2011

Abstract We present an experimental investigation on the Ge doping level dependence of the Electron Paramagnetic Resonance (EPR) signal spectral features of the Ge(1), Ge(2) and E'Ge defects induced in Ge doped silica. We have studied samples produced by sol–gel or PCVD techniques and doped with different amounts of Ge up to 20% by weight. The samples were gamma or beta ray irradiated and successively they were thermally treated to isolate the EPR signals of the different point defects. The data show that the EPR line shapes of the Ge(1) and the Ge(2) centers are progressively modified for doping level higher than 1%, whereas the line shape of the E'Ge defect appears independent from the do…

inorganic chemicalsMaterials scienceAnalytical chemistrychemistry.chemical_elementGermaniumSilica paramagnetic point defects Ge-doped silicasilice drogata difetti di punto risonanza magneticalaw.inventionsymbols.namesakeraman spectroscopylawCondensed Matter::SuperconductivityBeta particleMaterials ChemistryIrradiationElectron paramagnetic resonanceSol-gelSettore FIS/01 - Fisica SperimentaleDopingtechnology industry and agricultureCondensed Matter PhysicsCrystallographic defectElectronic Optical and Magnetic MaterialschemistryCeramics and Compositessymbolslipids (amino acids peptides and proteins)Condensed Matter::Strongly Correlated ElectronsRaman spectroscopyhuman activitiesJournal of Non-Crystalline Solids
researchProduct

EPR/ALANINE PELLETS WITH LOW Gd CONTENT FOR NEUTRON DOSIMETRY

2013

This paper reports on results obtained by electron paramagnetic resonance (EPR) measurements and Monte Carlo (MC) simulation on a blend of alanine added with low content of gadolinium oxide (5 % by weight) to improve the sensitivity to thermal neutron without excessively affecting tissue equivalence. The sensitivity is enhanced by this doping procedure of more an order of magnitude. The results are compared with those obtained with the addition of boric acid (50 % by weight) where boron is in its natural isotopic composition in order to produce low-cost EPR dosemeters. The gadolinium addition influences neutron sensitivity more than the boron addition. The presence of additives does not sub…

inorganic chemicalsMaterials scienceGadoliniumAnalytical chemistrychemistry.chemical_elementGadoliniumRadiation Dosagelaw.inventionBoric acidchemistry.chemical_compoundBoric AcidsIsotopeslawRadiology Nuclear Medicine and imagingNeutronIrradiationBoronElectron paramagnetic resonanceRadiometryNeutronsRadiationAlanineRadiological and Ultrasound Technologybusiness.industryElectron paramagnetic resonance (EPR) alanine pellet gadolinium Monte Carlo (MC) simulation dosimetryDopingtechnology industry and agriculturePublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyGeneral MedicineNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryNuclear medicinebusinessMonte Carlo Method
researchProduct

Optical Properties of Natural and Synthetic Minerals

2015

The results of investigation of optical absorption and photoluminescence (PL) of topaz, beryl and yttrium aluminium garnet crystals doped with different concentrations of transition ions exposed to fast neutron irradiation and electron irradiation are presented. We suppose that irradiation leads to the formation of two types of complex centers: "Me2+-F+ (or F) centre" and complex centers, which consist of a cation vacancy and an impurity (iron, manganese and chromium) ion. Exchange interaction between radiation defects and impurity ions during neutron or electron irradiation gives rise to appearance of additional absorption and luminescence band broadening in investigated crystals.

inorganic chemicalsMaterials sciencePhotoluminescenceAbsorption spectroscopyAnalytical chemistrytechnology industry and agriculturechemistry.chemical_compoundCondensed Matter::Materials SciencechemistryYttrium aluminium garnetImpurityVacancy defectElectron beam processingPhysics::Atomic and Molecular ClustersIrradiationAbsorption (chemistry)inorganic compounds; absorption spectra; photoluminescence; neutron irradiationNuclear chemistryEnvironment. Technology. Resources.
researchProduct

Optical Properties of Irradiated Yttrium Aluminum Garnet

2012

The results of investigation of the photoluminescence (PL) and optical absorption of crystals Y3Al5O12(YAG) doped with different concentrations of manganese ions exposed to fast neutron irradiation and electron irradiation are presented. Photoluminescence spectra of YAG before neutron irradiation at T=80 K contain fine lines in orange region of spectrum, ascribed to Mn2+ ions in octahedral position. After irradiation band broadening is observed in the luminescence spectra of garnet crystals. Electron irradiation produced broad band with a complex structure related to Mn4+ ions. Exchange interaction between radiation defect and impurity ions during neutron irradiation and electron irradiatio…

inorganic chemicalsMaterials sciencePhotoluminescencePhysics::Instrumentation and DetectorsDopingAnalytical chemistryPhysics::Opticschemistry.chemical_elementYttriumSpectral lineIonCondensed Matter::Materials SciencechemistryElectron beam processingIrradiationLuminescenceNuclear chemistryIOP Conference Series: Materials Science and Engineering
researchProduct

Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field

2007

In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…

inorganic chemicalsMaterials sciencePhotonGadoliniumAnalytical chemistrychemistry.chemical_elementRadiation DosageSensitivity and SpecificityFluencelaw.inventionRadiation ProtectionRadiation MonitoringlawMaterials TestingThermalDosimetryRadiology Nuclear Medicine and imagingNeutronESR Dosimetry BNCTElectron paramagnetic resonanceNeutronsAlanineRadiationRadiological and Ultrasound Technologybusiness.industryElectron Spin Resonance Spectroscopytechnology industry and agriculturePublic Health Environmental and Occupational HealthReproducibility of ResultsEquipment DesignGeneral MedicineNeutron temperatureEquipment Failure AnalysischemistryCalibrationbiological scienceslipids (amino acids peptides and proteins)Nuclear medicinebusinessRadiation Protection Dosimetry
researchProduct