Search results for "Angiocardiography"
showing 7 items of 7 documents
Left ventricular volume determination using Albunex.
1996
The aim of this study was to assess the ability of intravenous injection of Albunex to improve left ventricular volume determination in patients with various cardiac diseases. It is conceivable that the intravenous injection of microbubbles could improve echocardiographic left ventricular border delineation leading to improved interobserver variability. Echocardiograms were obtained during simultaneous intravenous injection of 0.08 and 0.12 ml/kg Albunex (four-chamber view). Within 6 hours after the recording of the contrast echocardiograms routine left heart angiography was performed. Volumes were measured using the slice method in native and contrast echocardiograms as well as in the angi…
Angiocardiographic digital still images compressed via irreversible methods: concepts and experiments.
1997
Abstract We defined, implemented and tested two new methods for irreversible compression of angiocardiographic still images: brightness error limitation (BEL) and pseudo-gradient adaptive brightness and contrast error limitation (PABCEL). The scan path used to compress the digital images is based on the Peano–Hilbert plane-filling curve. The compression methods limit, for each pixel, the brightness errors introduced when approximating the original image (i.e. the difference between the values of corresponding pixels as grey levels). Additional limitations are imposed to the contrast error observed when considering along the scan path consecutive pixels of both the original and the reconstru…
Diagnóstico etilógico de la disfunción ventricular izquierda con tomografia computerizada: comparación con coronariografía y cardiorresonancia
2012
[EN] Introduction and objectives To evaluate the capability of multidetector computed tomography to diagnose the coronary etiology of left ventricular dysfunction compared with using invasive coronary angiography and magnetic resonance. Methods Forty consecutive patients with left ventricular dysfunction of uncertain etiology underwent invasive coronary angiography and contrast magnetic resonance. All patients were evaluated with multidetector computed tomography including coronary calcium presence and score, noninvasive coronary angiography, and myocardial tissue assessment. Results The sensitivity and specificity of the presence of coronary calcium to identify left ventricular dysfunction…
Relative incidence and mortality of congenital heart defects diagnosed by angiohemodynamic methods: a 17-year study.
1992
Over a 17-year period (January 1971 to January 1988), 2322 children, aged 0-14 years, were diagnosed as having congenital heart disease (CHD) by cardiac catheterization and angiography. Excluding those with highly complex or undiagnosed defects, there were 2156 children with CHD, 72.4% of whom were treated surgically, with a total surgical mortality rate of 24.1%. After a mean follow-up of 9 years the overall mortality of the cohort was 29.9%, 29.1% occurring in the first month of life, 39.6% between 1 month and 1 year, and 31.2% between 1 and 14 years. The incidence, mortality, and age at death of each cardiac defect are presented and compared with the results of other studies. The overall…
A Bottleneck Model of Imaging Systems for Digital Angiocardiography
1988
Some ten years ago, the performance of real-time digital subtraction angiocardiography was demonstrated for the first time [1]. Subtraction became in the years after 1980 nearly synonymous with digital angiography [2–4]. This image enhancement technique was certainly very efficient in paving the way for the digital approach to imaging. Relatively simple processors and memory structures could perform subtraction methods with some degree of success. However, even in that early stage, it was clear to many of those involved in the technical developments and in early clinical evaluations that subtraction was only one of many features that would motivate the change from traditional film technique…
Digital Acquisition and Processing of Video Angiocardiograms
1986
Angiocardiographic diagnosis is still mainly based on the visual assessment of radiographic projection images recorded on photographic film. Considerable amounts of contrast material have to be selectively injected into the circulation in order to make the regions of diagnostic relevance visible in the superposition of the shadows of tissue and bone structures displayed in these transmission images. In addition, selective angiocardiography requires exact positioning of the catheter, a time-consuming procedure which is not without risk. The processing of the angiographie films obtained is difficult to maintain at a constant high quality level, and this introduces an disadvantageous delay bet…
Determination of myocardial perfusion and coronary flow reserve by densitometric measurements: a selective classification of regions of interest
2002
To evaluate the functional effect of a coronary artery stenosis on the dependent myocardium, digitized coronary angiograms (DCAs) were recorded. The DCAs, acquired during heart catheterization, provide information about myocardial perfusion and coronary flow reserve of areas supplied by this coronary artery. For each analysis the myocardium is separated into different regions of interest (ROIs); 16 ROIs in the distribution of the LCA and 8 ROIs for the RCA. In addition to that, the ROIs of the diseased vessels are divided into ROIs which are proximal, within and distal to the stenosis. Using a semiautomatic procedure, densograms are constructed from which the parameter rise time is calculat…