Search results for "Anti nuclear"
showing 10 items of 415 documents
Application of computational fluid dynamics technique in electrodialysis/reverse electrodialysis processes
2022
This Chapter treats the application of CFD technique in ED/RED processes. CFD simulations are able to predict flow and mass transfer in channels filled with spacers or membrane profiles, by providing dimensionless correlations useful for process models. At a larger scale, manifolds of the stack and inlet/ outlet zones of the channel can be simulated. Numerical models can include the computation of the electrical potential, thus characterizing the process performance. Direct numerical simulations can elucidate the complex phenomenology of overlimiting transport and of chaotic electrokinetic flows.
Analisi numerica degli effetti della deformazione di membrane a scambio ionico sulla distribuzione dei fluidi in canali di Elettrodialisi
2019
L’elettrodialisi (ED) è una promettente tecnologia a membrana utilizzata in diversi campi, ad esempio nella dissalazione delle acque e nell’industria alimentare. L’ED usa un potenziale elettrico per indurre una migrazione selettiva di cationi ed anioni da una soluzione elettrolitica ad un’altra, sfruttando membrane a scambio ionico. Membrane anioniche e cationiche sono alternativamente collocate all’interno di una unità ED. A queste sono solitamente interposti spaziatori che prevengono il contatto tra le membrane e delineano i canali in cui scorrono le soluzioni. L’utilizzo di membrane profilate consente di costruire unità prive di tradizionali spaziatori a rete non conduttivi. In genere, l…
Probabilità di fuga di "particelle" nucleari da corpi a simmetria sferica
2008
Developments in numerical modelling of cardiovascular fluid dynamics
1998
THERP and HEART integrated methodology for human error assessment
2014
Medical errors are one of the leading causes of death and injury in radiation therapy administration as reported in the literature. This point out an overall deficiency in management allowing patient treatment in the absence of suitable quality assurance processes. Clinical records of major accidental exposure events in radiotherapy show that there is a combination of factors contributing to the accident such as deficient staff training, lack of independent checks, lack of quality control procedures, and absence of overall supervision. Another finding is that training generally addresses only normal situations and does not prepare radiotherapy staff for unusual situations, resulting in a la…
PROVE ED ESPERIMENTI DI VERIFICA DELLA SICUREZZA DEL REATTORE NUCLEARE DI RICERCA AGN-201 “COSTANZA”
2011
The “Zero Power” Nuclear Reactor AGN-201 “Costanza” available at Nuclear Engineering Department of Palermo University is a valuable tool for educational purpose and research. Besides being a useful tool for training of operators, without the time period limits on start-up and shut-down of the larger reactors, it allows the study of some phenomena regarding nuclear reactor physics, applied neutronics, neutron dosimetry, nuclear measurements as well as testing of nuclear instrumentation and methods. The experience of work and the obtained results highlight the simplicity of AGN-201 reactor control, its intrinsic safety and its overall versatility in various fields of Nuclear Engineering.
RELAP5 simulation of two-phase flow experiments in vertical helical tubes
2010
In the framework of the studies concerning the thermalfluid dynamic phenomena in helicoidal pipes of the innovative nuclear reactor IRIS steam generators, the Department of Nuclear Engineering of the University of Palermo in collaboration with the Politecnico di Torino Department of Energetics has been engaged in a work aimed to adapt, by implementing new suitable models, RELAP5/mod3.2.2β code to simulate the thermalfluid-dynamics and geometries such as the ones involved in helicoidal pipes. In fact this code is based on one-dimensional thermal-hydraulic relationships and presents limitations to model complicated geometry such as helicoidal pipes. Therefore the code was improved with additi…
FMECA Application in Tomotherapy: Comparison between Classic and Fuzzy Methodologies
2022
Accident analysis in radiotherapy highlighted the need to increase quality assurance (QA) programs by the identification of failures/errors with very low probability (rare event) but very severe consequences. In this field, a Failure Mode, Effects and Criticality Analysis (FMECA) technique, used in various industrial processes to rank critical events, has been met with much interest. The literature describes different FMECA methods; however, it is necessary to understand if these tools are incisive and effective in the healthcare sector. In this work, comparisons of FMECA methodologies in the risk assessment of patients undergoing treatments performed with helical tomotherapy are reported. …
MELCOR per lo Studio Integrale di Sequenze Incidentali su Reattori PWR da 900 MWe e valutazioni preliminari d'impatto a breve e medio raggio
2014
Il presente documento è stato preparato nel corso della seconda annualità dell'AdP ENEA-MSE nell'ambito dell'obiettivo B-Task B_1 (Sviluppo di una Metodologia per Valutazioni di Sicurezza in Condizioni Incidentali o di Pre-Emergenza) della Linea Progettuale 1 (Sviluppo competenze scientifiche nel campo della sicurezza nucleare). Esso riporta i principali risultati della simulazione MELCOR di un transitorio del tipo “short term Station Blackout (SBO)” con possibile rottura dei tubi a U del GV (Steam Generator Tube Rupture - SGTR) indotta da stress termici e un lavoro preliminare di raccolta di informazioni sulle potenzialità presentate da alcune piattaforma di simulazione ad oggi utilizzate …
Friction and Heat Transfer in Membrane Distillation Channels: An Experimental Study on Conventional and Novel Spacers
2022
The results of an experimental investigation on pressure drop and heat transfer in spacer-filled plane channels, which are representative of Membrane Distillation units, are presented and discussed. Local and mean heat transfer coefficients were obtained by using Thermochromic Liquid Crystals and Digital Image Processing. The performances of a novel spacer geometry, consisting of spheres that are connected by cylindrical rods, and are hereafter named spheres spacers, were compared with those of more conventional woven and overlapped spacers at equal values of the Reynolds number Re (in the range ~150 to ~2500), the pitch-to-channel height ratio, the flow attack angle and the thermal boundar…