Search results for "Aortic"

showing 10 items of 619 documents

Endovascular treatment of large and wide aortic neck: case report and literature review

2017

Large (24–34 mm) and wide (≥35 mm) aortic necks are a contraindication to endovascular aneurysm repair (EVAR). A 63-year-old man, unfit for conventional surgery, presented a 79 mm abdominal aortic aneurysm with 36.5 mm aortic neck and a 62 mm right common iliac artery aneurysm. He was treated endovascularly with standard commercially available stent-graft using the so-called ‘funnel technique’; by placing a thoracic stent-graft inside a bifurcated device to achieve proximal sealing. The completion angiography and the 6 months follow-up with computed tomography showed no stent-graft migration, limb occlusion or endoleak. The literature review reported 179 cases of large aortic neck managed w…

MalePulmonary and Respiratory Medicinemedicine.medical_specialtyTime FactorsEndoleakTime Factormedicine.medical_treatmentRight Common Iliac Artery030204 cardiovascular system & hematologyEndovascular aneurysm repairSettore MED/22 - Chirurgia Vascolare030218 nuclear medicine & medical imaging03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmOcclusionmedicineStentHumanscardiovascular diseasesComplications; Endoleak; Funnel technique; Large neck; Migration; Aortic Aneurysm Abdominal; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Humans; Male; Middle Aged; Time Factors; Tomography X-Ray Computed; Stents; Surgery; Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular MedicineContraindicationMigrationEndovascular Proceduremedicine.diagnostic_testLarge neckbusiness.industryEndovascular ProceduresGeneral MedicineMiddle Agedmedicine.diseaseAbdominal aortic aneurysmSurgerysurgical procedures operativeAngiographycardiovascular systemStentsSurgeryAortic neckbusinessFunnel techniqueTomography X-Ray ComputedCardiology and Cardiovascular MedicineComplicationAortic Aneurysm AbdominalHuman
researchProduct

Outcome after surgery for acute aortic dissection type A in patients over 70 years: data analysis from the German Registry for Acute Aortic Dissectio…

2010

Objective: The number of elderly patients undergoing emergency surgery for acute aortic dissection type A (AADA) is rising. Published results report a higher risk for thesepatients comparedwith younger patients. The aim of our study wasto analyse the surgicaloutcomeof these patients and to identify those at risk. Methods: Between July 2006 and June 2009, 44 centres participating in the German Registry for Acute Aortic Dissection Type A (GERAADA) reported a total of 1558 patients. As many as 381 patients were between 70 and 80 years of age (septuagenarians), while 83 patients were 80 years and older (octogenarians). We compared the clinical features and events occurring 30 days after surgery…

MalePulmonary and Respiratory Medicinemedicine.medical_specialtylaw.inventionBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmlawGermanyCardiac tamponademedicineHumansIn patientRegistriesAgedAged 80 and overAortic dissectionbusiness.industryPatient SelectionAge FactorsGeneral MedicineOdds ratiomedicine.diseaseIntensive care unitConfidence intervalAortic AneurysmSurgeryAortic DissectionTreatment OutcomeAcute DiseaseFemaleSurgeryEmergenciesCardiology and Cardiovascular MedicinebusinessEuropean Journal of Cardio-Thoracic Surgery
researchProduct

Mortality in patients with acute aortic dissection type A: analysis of pre- and intraoperative risk factors from the German Registry for Acute Aortic…

2015

Acute aortic dissection type A (AADA) is an emergency with excessive mortality if surgery is delayed. Knowledge about independent predictors of mortality on surgically treated AADA patients is scarce. Therefore, this study was conducted to identify pre- and intraoperative risk factors for death.Between July 2006 and June 2010, 2137 surgically treated patients with AADA were enrolled in a multicentre, prospective German Registry for Acute Aortic Dissection type A (GERAADA), presenting perioperative status, operative strategies, postoperative outcomes and AADA-related risk factors for death. Multiple logistic regression analysis was performed to identify the influence of different parameters …

MalePulmonary and Respiratory Medicinemedicine.medical_specialtymedicine.medical_treatmentOperative TimeMyocardial IschemiaIschemiaDisease030204 cardiovascular system & hematologyBrain Ischemia03 medical and health sciences0302 clinical medicineIschemiaRisk FactorsGermanymedicine.arteryHumansMedicineProspective StudiesRegistriesCardiopulmonary resuscitationIntraoperative ComplicationsAortic dissectionLegAortaAortic Aneurysm Thoracicbusiness.industryGeneral MedicineOdds ratioPerioperativeMiddle Agedmedicine.diseaseSurgeryAortic DissectionTreatment OutcomeHemiparesis030228 respiratory systemAcute DiseaseFemaleSurgerymedicine.symptomCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalEuropean Journal of Cardio-Thoracic Surgery
researchProduct

Compliance and Pulse Wave Velocity Assessed by MRI Detect Early Aortic Impairment in Young Patients With Mutation of the Smooth Muscle Myosin Heavy C…

2008

Purpose To evaluate aortic elasticity with MRI on young asymptomatic individuals with mutation of the smooth muscle myosin heavy chain in whom aortic enlargement is not present. Materials and Methods Aortic compliance, aortic distensibility, and pulse wave velocity (PWV) were semiautomatically measured from MRI in 8 asymptomatic subjects having a mutation of the MYH11 gene (M+) and 21 nonmutated relatives (M−) of similar age, sex, and blood pressure characteristics. Results Despite a similar aortic diameter in both groups, the aortic compliance and distensibility were significantly lower in M+ subjects compared with M− (0.84 ± 0.33 versus 2.03 ± 0.54 mm2/mmHg, 1.18 ± 0.62 10−3 versus 5.11 ±…

MalePulsatile flow030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging0302 clinical medicinemagnetic resonance imaginggeneticsPulse wave velocityComputingMilieux_MISCELLANEOUSmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingPrognosisPulsatile FlowAortic valve stenosiscardiovascular systemCardiologyElasticity Imaging TechniquesFemalemedicine.symptomAlgorithmsBlood Flow VelocityAdultmedicine.medical_specialtypulse wave velocityAortic Valve InsufficiencySensitivity and SpecificityAsymptomaticYoung Adult03 medical and health sciencesElastic Modulusmedicine.arteryInternal medicineImage Interpretation Computer-Assistedmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansGenetic Predisposition to DiseaseRadiology Nuclear Medicine and imagingAortaMyosin Heavy ChainsReceiver operating characteristicbusiness.industryReproducibility of ResultsMagnetic resonance imagingAortic Valve StenosisImage Enhancementmedicine.diseaseaortaBlood pressureMutationelasticitybusiness
researchProduct

Obstructive uropathy following aortofemoral graft surgery.

1991

Fifty patients who had undergone aorto-bifemoral bypass with a bifurcated Dacron graft for aortoiliac arteriosclerotic obliteration were examined with real-time sectorial ultrasound to screen for the presence of hydronephrosis. Hydronephrosis was detected in only 1 case. The low incidence of this complication in our cases may be due to the fact that all our patients were explored at least 1 year after surgery. Some may have developed hydronephrosis early, but this may have resolved spontaneously during the first year after the operation, thus remaining undiagnosed. Pathogenic mechanisms suggested for the development of hydronephrosis and therapeutic approaches are discussed. We conclude tha…

MaleReconstructive surgerymedicine.medical_specialtyUrologyUrinary systemmedicine.medical_treatmentAortic DiseasesArterial Occlusive DiseasesFemoral arteryHydronephrosisProsthesisPostoperative Complicationsmedicine.arterymedicineHumansAorta AbdominalHydronephrosisObstructive uropathyUltrasonographybusiness.industryAbdominal aortaMiddle Agedmedicine.diseaseSurgeryBlood Vessel ProsthesisFemoral ArteryRadiologybusinessComplicationFollow-Up StudiesUrologia internationalis
researchProduct

Identification of optimal device combinations for the chimney endovascular aneurysm repair technique within the PERICLES registry

2018

Abstract Objective The ideal stent combination for chimney endovascular aneurysm repair remains undetermined. Therefore, we sought to identify optimal aortic and chimney stent combinations that are associated with the best outcomes by analyzing the worldwide collected experience in the PERformance of chImney technique for the treatment of Complex aortic pathoLogiES (PERICLES) registry. Methods The PERICLES registry was reviewed for patients with pararenal aortic disease electively treated from 2008 to 2014. Eleven different aortic devices were identified with three distinct subgroups: group A (n = 224), nitinol/polyester; group B (n = 105), stainless steel/polyester; and group C (n = 69), n…

MaleRegistrieTime FactorsEndoleakmedicine.medical_treatmentComorbidity030204 cardiovascular system & hematology030230 surgeryEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicineRisk FactorsRetrospective StudieOcclusionOdds RatioStentRegistriesMultivariate AnalysiPolytetrafluoroethyleneAged 80 and overEndovascular ProceduresHazard ratioGraft Occlusion VascularEuropeBlood Vessel ProsthesiTreatment OutcomeCardiothoracic surgeryStentsFemaleCardiology and Cardiovascular MedicineSTENT GRAFT; CHIMENY GRAFT; CHIMNEY TECHINQUEHumanUnited Statemedicine.medical_specialtyHospitals Low-VolumeTime FactorPolyestersPolyesterProsthesis DesignDisease-Free Survival03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesisAlloysmedicineHumansProportional Hazards ModelsRetrospective StudiesAgedEndovascular ProcedureAortic Aneurysm Thoracicbusiness.industryRisk FactorStentOdds ratiomedicine.diseaseStainless SteelUnited StatesBlood Vessel ProsthesisSurgeryMultivariate AnalysisAlloyProportional Hazards ModelSurgerybusinessHospitals High-VolumeAortic Aneurysm Abdominal
researchProduct

Outcomes of Patients With Asymptomatic Aortic Stenosis Followed Up in Heart Valve Clinics

2018

International audience; Importance - The natural history and the management of patients with asymptomatic aortic stenosis (AS) have not been fully examined in the current era. Objective - To determine the clinical outcomes of patients with asymptomatic AS using data from the Heart Valve Clinic International Database. Design, setting, and participants - This registry was assembled by merging data from prospectively gathered institutional databases from 10 heart valve clinics in Europe, Canada, and the United States. Asymptomatic patients with an aortic valve area of 1.5 cm2 or less and preserved left ventricular ejection fraction (LVEF) greater than 50% at entry were considered for the prese…

MaleRegistrieUnited StateCanadamedicine.medical_specialty030204 cardiovascular system & hematologyAsymptomaticSudden deathDisease-Free Survival03 medical and health sciences0302 clinical medicineAortic valve replacementRetrospective StudieInternal medicinemedicineHumansProspective StudiesRegistries030212 general & internal medicineHeart valveWatchful WaitingProspective cohort studyRetrospective StudiesAgedAged 80 and overAsymptomatic DiseaseEjection fractionbusiness.industryDisease ManagementAortic Valve StenosisMiddle Agedmedicine.diseaseAortic Valve StenosiUnited States3. Good healthEuropeProspective StudieStenosisDeath Sudden Cardiacmedicine.anatomical_structureAortic valve stenosisAsymptomatic DiseasesCardiology[SDV.IB]Life Sciences [q-bio]/BioengineeringFemalemedicine.symptombusinessCardiology and Cardiovascular MedicineHuman
researchProduct

Modified Danielson Technique for Prosthetic Aortic Valve Endocarditis and Aortoventricular Discontinuity

2020

Endocarditis is a devastating complication of prosthetic aortic valve replacement. The infective process can destroy aortic annulus tissue, making conventional surgical valve replacement difficult or impossible and causing aortoventricular discontinuity. Several treatment techniques have been proposed. One of these, the Danielson technique, involves translocating the aortic valve to the native ascending aorta, débriding the abscess cavity, closing the coronary ostia, and bypassing the coronary arteries with a Y anastomosis between 2 vein grafts. We describe our use of a modified Danielson technique in a 68-year-old man with advanced prosthetic valve endocarditis that was associated with aor…

MaleReoperationAortic valvemedicine.medical_specialtyProsthesis-Related Infectionsmedicine.medical_treatmentAnastomosisValve replacementAortic valve replacementmedicine.arteryAscending aortaHumansMedicineEndocarditisCardiac skeletonCardiac Surgical ProceduresAgedbusiness.industryEndocarditis Bacterialmedicine.diseaseTechniquesSurgeryCoronary arteriesmedicine.anatomical_structureEchocardiographyAortic ValveHeart Valve Prosthesiscardiovascular systemCardiology and Cardiovascular MedicinebusinessTexas Heart Institute Journal
researchProduct

Supracoronary ascending aortic replacement in patients with acute aortic dissection type A: What happens to the aortic root in the long run?

2013

ObjectiveOur objective was to determine long-term outcome predictors for patients with acute aortic dissection type A (AADA) and aortic root involvement.MethodsFrom 2001 through 2009, 119 of 152 patients operated on for AADA at a tertiary medical center underwent supracoronary ascending aortic replacement (52 women; mean age, 61 ± 15 years). Those with at least 1-year follow-up (n = 97) were retrospectively assessed for preoperative aortic root disease. Follow-up data were assessed for evidence of new-onset aortic root disease by computed tomography and echocardiography, and for reoperation for aortic root disease.ResultsMedian follow-up was 33.8 months (range, 0-112 months). Twenty-six (27…

MaleReoperationPulmonary and Respiratory Medicinemedicine.medical_specialtyTime FactorsAortic rootAortic Valve InsufficiencyComputed tomographyKaplan-Meier EstimateDissection (medical)Independent predictorAortographySeverity of Illness IndexNew onsetTertiary Care CentersBlood Vessel Prosthesis ImplantationPredictive Value of TestsRisk FactorsInternal medicineOdds RatiomedicineHumansIn patientAgedRetrospective StudiesUltrasonographyAortic dissectionmedicine.diagnostic_testbusiness.industryMean ageMiddle AgedSinus of Valsalvamedicine.diseaseAortic AneurysmSurgeryAortic DissectionLogistic ModelsTreatment OutcomeAcute DiseaseMultivariate Analysiscardiovascular systemCardiologyFemaleSurgeryTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessDilatation PathologicThe Journal of Thoracic and Cardiovascular Surgery
researchProduct

Use and durability of femoral vein for autologous reconstruction with infection of the aortoiliofemoral axis.

2014

Objective To analyze early and late mortality, venous morbidity, reinfection, and freedom from reintervention after using the femoral vein (FV) for vascular reconstruction with infection of the aortoiliofemoral axis. Methods By reviewing our database, 86 patients could be identified with implantation of FV grafts in infected fields between November 1995 and July 2012. The patient records were retrospectively analyzed and follow-up information obtained from patients or their general physician. Seventy-one patients presented with prosthetic graft infection and 15 with an infected aneurysm. For data analysis, patients were divided into an aortoiliac (n = 67) and a femoral group (n = 19). Study…

MaleReoperationmedicine.medical_specialtyProsthesis-Related InfectionsTime FactorsDeep veinLimb salvageFemoral veinKaplan-Meier EstimateAortographyBlood Vessel Prosthesis ImplantationAneurysmRecurrenceRisk FactorsmedicineHumansAutograftsVascular PatencyAgedRetrospective StudiesAged 80 and overVenous Thrombosisbusiness.industryIncidence (epidemiology)Operative mortalityGraft Occlusion VascularFemoral VeinMiddle AgedPlastic Surgery Proceduresmedicine.diseaseLimb SalvageThrombosisSurgeryAortic AneurysmBlood Vessel ProsthesisFemoral ArteryVenous thrombosismedicine.anatomical_structureTreatment OutcomeIliac AneurysmSurgeryFemalebusinessCardiology and Cardiovascular MedicineTomography X-Ray ComputedAneurysm InfectedJournal of vascular surgery
researchProduct