Search results for "Aortic"

showing 10 items of 619 documents

Ascending Aorta Resection and End-to-End Anastomosis: Redistribution of Wall Shear Stress Induced by a Bioprosthetic Heart Valve

2020

Although aortic resection and end-to-end anastomosis are applied to repair ascending aortic aneurysm, there is a lack of information on the late risk of post-operative complications, such as aortic dissection and aneurysmal re-dilatation. It is recognized that altered hemodynamic forces exerted on an aortic wall play an important role on dissection and aneurysm formation. We present a case in which the hemodynamic forces were investigated prior and after repair of an ascending aorta treated by resection with end-to-end anastomosis and a bioprosthetic heart valve. Post-operative wall shear stress was redistributed uniformly along the vessel circumference, and this may suggest a reduced risk …

aorta/aorticmedicine.medical_specialty0206 medical engineeringascending aortalcsh:Medicine02 engineering and technologyDissection (medical)030204 cardiovascular system & hematologyAnastomosis03 medical and health sciencesAortic aneurysmcomputational fluid dynamic0302 clinical medicineAneurysmInternal medicinemedicine.arteryAscending aortamedicineShear stressHeart valveaortic dissectionAortaAortic dissectionbusiness.industrylcsh:RGeneral Medicinemedicine.disease020601 biomedical engineeringmedicine.anatomical_structureCardiologycardiovascular systemaneurysmbusinessaortic
researchProduct

Chimney and Periscope Grafts Observed Over 2 Years After Their Use to Revascularize 169 Renovisceral Branches in 77 Patients With Complex Aortic Aneu…

2013

Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch to visceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination…

aortic aneurysm pararenal aortic aneurysm thoracoabdominal aortic aneurysm aortic arch endovascular aneurysm repair renal artery superficial mesenteric artery celiac trunk target vessel stent-graft side branch chimney graft periscope graft parallel graft target vessel patency endoleak side branch occlusionSettore MED/22 - Chirurgia Vascolare
researchProduct

Stress Echocardiography and Strain in Aortic Regurgitation (SESAR protocol): Left ventricular contractile reserve and myocardial work in asymptomatic…

2020

Objectives: To analyze left ventricular (LV) myocardial deformation and contractile reserve (CR) in asymptomatic patients with severe aortic regurgitation (AR) at rest and during exercise, and their correlation with functional capacity. Background: The natural history of chronic AR is characterized by a prolonged silent phase before onset of symptoms and overt LV dysfunction. Assessment of LV systolic function and contractile reserve has an important role in the decision-making of AR asymptomatic patients. Methods: Standard echo, lung ultrasound, and LV 2D speckle tracking strain were performed at rest and during exercise in asymptomatic patients with severe AR and in age- and sex-comparabl…

aortic regurgitation contractile reserve myocardial work stress echocardiography two-dimensional strainMalemedicine.medical_specialtyLongitudinal strainstress echocardiographyHeart VentriclesAortic Valve InsufficiencyStrain (injury)Regurgitation (circulation)030204 cardiovascular system & hematologyAsymptomatictwo-dimensional strainVentricular Function LeftHeart Ventricle03 medical and health sciencesVentricular Dysfunction Left0302 clinical medicineInternal medicinecontractile reserveEchocardiography StremedicineStress EchocardiographyHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineSubclinical infectionEjection fractionbusiness.industryStroke Volumeaortic regurgitation; contractile reserve; myocardial work; stress echocardiography; two-dimensional strainmedicine.diseaseaortic regurgitationLung ultrasoundmyocardial workCardiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessHumanEchocardiography StressEchocardiography (Mount Kisco, N.Y.)REFERENCES
researchProduct

Early abdominal aortic rupture after Nellix endovascular aneurysm sealing

2018

This case concerns a 73 year-old woman, that suffered from symptomatic aortic abdominal aneurysm. Due to the complex anatomy of the aneurysm she was treated with nellix endovascular aneurysm seal device. The implantation was successful, and the completion angiography showed no endoleak. On the 9th day after the procedure, the patient presented severe abdominal pain with peritoneal symptoms, significant anemia and hypovolemic shock. The patient was subject to emergency laparotomy. The aortic rupture was identified. The Nellix device was removed and replaced with bifurcated silver-covered PTFE graft.

aortic ruptureendovascular proceduresEVARNellixEVASActa Angiologica
researchProduct

Clinical outcomes of aortic valve repair in asymptomatic patients with chronic severe aortic valve regurgitation.

2009

aortic valve repair asymptomatic patients
researchProduct

Post-operative computed tomography imaging evaluation of ascending aorta surgery

2021

Ascending thoracic aorta disease is often a life-threatening condition. Aortic aneurysm and aortic dissection are the most frequent ascending aorta diseases requiring surgical intervention. Surgical repair techniques of the ascending aorta are various; they include reconstruction of the ascending aorta by using a graft with or without a prosthetic valve, reconstruction with a composite artificial graft or using a biological graft, and reconstruction of the ascending aorta with a composite graft preserving the native valve and arch repair. The radiologist plays a key role in the identification of post-operative complications; differentiation from normal postoperative findings is fundamental.…

ascending aorta-surgerymedicine.medical_specialtypost-operative complicationsComputed tomographyelephant-trunk procedureArtificial graftAortic aneurysmmedicine.arteryAscending aortapost-operative CT imagingMedicineThoracic aortaPost operativeBentall-De Bono procedureBentall-De BonprocedureAortic dissectionSurgical repairReview Papermedicine.diagnostic_testbusiness.industrymedicine.diseaseSurgerygraftcardiovascular systemSettore MED/36 - Diagnostica Per Immagini E Radioterapiabusiness
researchProduct

Técnicas de preservación de válvula aórtica

2015

ResumenLa prótesis valvular aórtica perfecta e ideal no existe por el momento en nuestra realidad quirúrgica y, conscientes de ello, los cirujanos trabajamos en mejorar nuestras técnicas. En este artículo exponemos las principales técnicas actuales de reparación aórtica.AbstractThe perfect and ideal aortic valve prosthesis does not exist yet in our surgical actually, and aware of it surgeons work on improving our techniques. In this paper we present the main current techniques of aortic repair.

business.industrylcsh:Rlcsh:Surgerylcsh:Medicinelcsh:RD1-811Válvula AórticaReparaciónCirugíaAortic ValveMedicineSurgeryCardiology and Cardiovascular MedicinebusinessHumanitiesRepairCirugía Cardiovascular
researchProduct

Dataset related to the article "LITHOTRIPSY OF CALCIFIED AORTIC VALVE LEAFLETS BY A NOVEL ULTRASOUND TRANSCATHETER-BASED DEVICE"

2022

This record contains raw data related to the article “LITHOTRIPSY OF CALCIFIED AORTIC VALVE LEAFLETS BY A NOVEL ULTRASOUND TRANSCATHETER-BASED DEVICE” The increasing incidence of calcific aortic valve disease necessitates the elaboration of new strategies to retard the progression of the pathology with an innovative solution. While the increasing diffusion of the transcatheter aortic valve replacements (TAVRs) allows a mini-invasive approach to aortic valve substitution as an alternative to conventional surgical replacement (SAVR) in an always larger patient population, TAVR implantation still has contraindications for young patients. In addition, it is liable to undergo calcification with …

calcific aortic valve disease (CAVD); lithotripsy—methods; medical device; ultrasound; valve leaflets; valvuloplasty
researchProduct

Ezetimibe, cardiovascular risk and atherogenic dyslipidaemia.

2010

Ezetimibe is a selective cholesterol absorption inhibitor with an excellent side-effect profile, able to reduce low-density lipoprotein (LDL) cholesterol by 15-25% from baseline in monotherapy and on top of statins and fibrates. Yet, it seems that ezetimibe produces quantitative rather than qualitative changes in LDL, with small net effects on atherogenic dyslipidaemia. This is supported by findings from the Ezetimibe and Simvastatin in Hypercholesterolemia Enhances Atherosclerosis Regression (ENHANCE) study on atherosclerosis progression, where the addition of ezetimibe to simvastatin in patients with heterozygous familial hypercholesterolaemia did not affect the mean change in carotid int…

cardiovascular riskAortic valvemedicine.medical_specialtydyslipidaemiamedicine.drug_classezetimibe cardiovascular risk atherosclerosis dyslipidaemiachemistry.chemical_compoundEzetimibeInternal medicineClinical endpointMedicineCholesterol absorption inhibitorcardiovascular diseasesReview Paperbusiness.industryCholesterolnutritional and metabolic diseasesGeneral Medicinemedicine.diseaseStenosismedicine.anatomical_structureEndocrinologychemistrySimvastatinCardiologylipids (amino acids peptides and proteins)atherosclerosisbusinessezetimibeLipoproteinmedicine.drug
researchProduct

Aortic Stiffness in HIV Infection with and without Antiretroviral Therapy. A Meta-analysis of Observational Studies

2020

Background: The risk of Cardiovascular (CV) events is higher in HIV-infected patients (HIV+) compared to HIV-uninfected persons (HIV−). Large artery stiffness, a well-documented predictor of adverse CV prognosis, may mediate this enhanced risk. It is usually assessed by measuring aortic Pulse Wave Velocity (aPWV). Studies examining arterial stiffness in HIV+ yielded inconsistent results. We performed a meta-analysis with the aim to evaluate the association of HIV infection and its therapy [Antiretroviral Therapy (ART)] with aPWV. Design and Method: The Standardized Mean Difference (SMD) and corresponding 95% confidence intervals were calculated for aPWV in different comparison groups. Stati…

cardiovascular riskmedicine.medical_specialtySettore MED/09 - Medicina Internaaortic stiffnessSettore MED/17 - Malattie Infettivebusiness.industrypulse wave velocityHIV infection cardiovascular risk pulse wave velocity aortic stiffnessHuman immunodeficiency virus (HIV)virus diseasesSpecialties of internal medicineGeneral Medicinemedicine.disease_causeHIV infectionAntiretroviral therapyRC581-951Meta-analysisInternal medicineRC666-701MedicineDiseases of the circulatory (Cardiovascular) systemObservational studyAortic stiffnessbusinessPulse wave velocityArtery Research
researchProduct