Search results for "Aquarium"
showing 10 items of 18 documents
Removal of acetone from air emissions by biotrickling filters: providing solutions from laboratory to full-scale
2018
A full-scale biotrickling filter (BTF) treating acetone air emissions of wood-coating activities showed difficulties to achieve outlet concentrations lower than 125 mg C m-3, especially for high inlet concentrations and oscillating emissions. To solve this problem, a laboratory investigation on acetone removal was carried out simulating typical industrial conditions: discontinuous and variable inlet concentrations and intermittent spraying. The results were evaluated in terms of removal efficiency and outlet gas emission pattern. Industrial emissions and operational protocols were simulated: inlet load up to 70 g C m-3 h-1 during 2 cycles of 4 h per day and intermittent trickling of 15 min …
Dynamic Mathematical Modelling of the Removal of Hydrophilic VOCs by Biotrickling Filters
2015
A mathematical model for the simulation of the removal of hydrophilic compounds using biotrickling filtration was developed. The model takes into account that biotrickling filters operate by using an intermittent spraying pattern. During spraying periods, a mobile liquid phase was considered, while during non-spraying periods, a stagnant liquid phase was considered. The model was calibrated and validated with data from laboratory- and industrial-scale biotrickling filters. The laboratory experiments exhibited peaks of pollutants in the outlet of the biotrickling filter during spraying periods, while during non-spraying periods, near complete removal of the pollutant was achieved. The gaseou…
Evaluation and comparison of trace metal accumulation in different tissues of potential bioindicator organisms: Macrobenthic filter feedersStyela pli…
2016
Trace metal concentrations were measured in different tissues of Sabella spallanzanii, Styela plicata, and Mytilus galloprovincialis collected in the Termini Imerese Harbor (Sicily, Italy) to evaluate the potential use of these species as bioindicators. Higher bioaccumulation factors (BAFs) were calculated in the tube of S. spallanzanii, except for As, which had a higher BAF in the branchial crown of the same species. Regarding the other species analyzed, higher BAFs were found in the digestive gland of M. galloprovincialis. An exception was Pb, which was significantly more concentrated in the branchial basket and tunic of S. plicata. The BAFs calculated in the present study show that all t…
The effects of different combinations of fixed and moving bed bioreactors on rainbow trout (Oncorhynchus mykiss) growth and health, water quality and…
2019
Abstract The effect of bioreactor design on nitrification efficiency has been well studied, but less is known about the overall impacts on water quality. Besides nitrification, submerged fixed bed bioreactors (FBBR) trap fine solid particles, whereas moving bed bioreactors (MBBR) grind solids, possibly increasing solids and particle accumulation in the system. In this experiment, the effects of different combinations of fixed bed and moving bed bioreactors on water quality, solids removal, particle size distribution, fish health based on histopathological changes and nitrification efficiency were studied in laboratory scale recirculating aquaculture systems (RAS) with rainbow trout (Oncorhy…
Performance and feasibility of biotrickling filtration in the control of styrene industrial air emissions
2017
Abstract The performance and feasibility of a pilot unit of biotrickling filter (BTF) for the treatment of industrial emissions polluted by styrene was investigated for one year at a fiber reinforced plastic industrial site. The pilot unit was packed with a structured material with a volume of 0.6 m3. Monitoring results have shown successful treatment of the industrial styrene emissions working at empty bed residence times (EBRT) between 31 and 66 s. The best performance was obtained after 300 days when a more stable biofilm had been developed, obtaining the highest elimination capacity of 18.8 g m−3 h−1 (removal efficiency of 75.6%) working at 31 s of EBRT. In addition, a photocatalytic re…
Use Of Plants To Remediate Soil Polluted With Oil
2015
In the present investigation the growing and development ability of various annual and perennial plants to grow on model peat substrate artificially polluted with oil products in the range of concentrations from 1 to 5% was evaluated. The highest tolerance towards peat contamination by oil products has been demonstrated by three annual crops (maize, oat and lupine). These plants were tested for phytoremediation of polluted black soil from the area of oil refinery plant (Mazeikiai, Lithuania), which was treated by association of oil oxidizing bacteria up to residual concentration of the oil products of 4.5 %. The maize plants revealed the highest remediation ability: oil content in the soil …
Photocatalytic ozonation for a sustainable aquaculture: A long-term test in a seawater aquarium
2019
Abstract A long-term test at a laboratory scale with a closed system (a coral reef aquarium) has been carried out to study the potentialities of photocatalytic ozonation and photocatalysis for the removal of noxious organic compounds in recirculating systems (aquaria and recirculating aquaculture systems) working with a minimum make up of new water. Attention has been focused not only on the depuration capabilities but also on possible negative phenomena, some of which could become apparent only at long times. After having tuned the system by setting appropriate operating conditions and procedures, positive results were obtained. In particular, it was observed that the alternation of photoc…
Enhanced styrene removal in a two-phase partitioning bioreactor operated as a biotrickling filter: Towards full-scale applications
2017
Abstract Styrene vapor abatement was investigated in a two-phase partitioning bioreactor operated as a biotrickling filter (TPPB-BTF). The removal performance of the TPPB-BTF was simultaneously compared with a conventional BTF, which served as a control. Industrial-grade silicone oil was used as the non-aqueous phase in the TPPB-BTF due to its high affinity for styrene. Both bioreactors were operated at styrene inlet concentrations ranging from 55 to 323 mg C m −3 and empty bed residence times (EBRT) of 15–30 s, corresponding to pollutant loading rates of 13–77 g C m −3 h −1 . Both bioreactors exhibited styrene removal efficiencies (REs) higher than 90% at an EBRT of 30 s. Nevertheless, th…
Anaerobic thermophilic (55°C) treatment of TMP whitewater in reactors based on biomass attachment and entrapment
1999
Abstract Thermomechanical pulping (TMP) whitewater was treated in thermophilic (55°C) anaerobic laboratory-scale reactors using three different reactor configurations. In all reactors up to 70 % COD removals were achieved. The anaerobic hybrid reactor, composed of an upflow anaerobic sludge blanket (UASB) and a filter, gave degradation rates up to 10 kg COD/m 3 d at loading rates of 15 kg COD/m 3 d and hydraulic retention time (HRT) of 3.1 hours. The anaerobic multi-stage reactor, consisting of three compartments, each packed with granular sludge and carrier elements, gave degradation rates up to 9 kg COD/m 3 d at loading rates of 15–16 kg COD/m 3 d, and HRT down to 2.6 hours. Clogging and …
Performance of a pilot-scale biotrickling filter in controlling the volatile organic compound emissions in a furniture manufacturing facility.
2009
A 0.75-m3 pilot-scale biotrickling filter was run for over 1 yr in a Spanish furniture company to evaluate its performance in the removal of volatile organic compounds (VOCs) contained in the emission of two different paint spray booths. The first one was an open front booth used to manually paint furniture, and the second focus was an automatically operated closed booth operated to paint pieces of furniture. In both cases, the VOC emissions were very irregular, with rapid and extreme fluctuations. The pilot plant was operated at an empty bed residence time (EBRT) ranging from 10 to 40 sec, and good removal efficiencies of VOCs were usually obtained. When a buffering activated carbon prefil…