Search results for "Aromatic Hydrocarbons"
showing 10 items of 107 documents
Molecular analysis of the catechol-degrading bacterial community in a coal wasteland heavily contaminated with PAHs
2010
International audience; A PCR-based molecular tool was developed to estimate the diversity of the catechol-degrading bacterial community in a coal wasteland heavily contaminated with PAHS. A degenerate primer pair specific to catA sequences was designed by multiple alignment of known sequences coding a key intermediate of the β-ketoadiapate pathway degrading catechol, namely catechol 1,2-dioxygenase. The specificity of this primer pair was assessed in 21 pure strains by PCR and sequencing. Comparison of the 16S rDNA and catA phylogenies revealed an absence of congruence between these two genes. The primer set was able to amplify catA sequences in DNA extracts from an industrial soil highly …
New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aroma…
2008
Abstract Miniaturized matrix solid-phase dispersion (MSPD) was developed for the extraction of common polycyclic aromatic hydrocarbons (PAHs) from bivalve samples (100 mg, dry weight). Additional clean-up and analyte enrichment was accomplished by in-tube solid-phase microextraction (SPME). For this purpose the extracts collected after MSPD were diluted with water and injected into a capillary column coated with the extractive phase. This capillary column was connected to the analytical column by means of a switching valve. Separation and quantification of the PAHs were carried out using a monolithic LC column and fluorescence detection. Since the in-tube SPME device allowed the processing …
Analysis of Polycyclic Aromatic Hydrocarbons and Their Oxygen-Containing Derivatives and Metabolites in Soils
2010
Although polycyclic aromatic hydrocarbons (PAHs) have been extensively studied, the knowledge of their oxygen-containing derivatives and metabolites (OPAHs) in soils is limited. We modified and tested an existing analytical protocol involving pressurized liquid extraction of soil followed by fractionation of target compounds into PAHs and OPAHs on a silica gel column and gas chromatography/ mass spectrometry-based separation and quantification. Polycyclic aromatic hydrocarbons and carbonyl-OPAHs were quantified directly after separation on silica gel columns, and hydroxyl/carboxyl-OPAHs were quantified after silylation with N,O-bis(trimethylsilyl)trifluoroacetamide. Recoveries between 78 an…
Comparison of different methods for extraction of polycyclic aromatic hydrocarbons (PAHs) from Sicilian (Italy) coastal area sediments.
2012
This paper describes a work aimed at improving the conditions of an extraction method, coupling GC-MS determination, for the analysis without cleanup phase, of polycyclic aromatic hydrocarbons (PAHs) from sediment samples. The automatic Soxhlet extraction in warm mode (using Extraction System B-811 Standard, Buchi) has demonstrated advantages for automation, reduced extraction time, and lower solvent use than for conventional Soxhlet extraction. Under these conditions, the recoveries are very good as they resulted greater than 85 % and, in most of the cases, near 100 %. The repeatability is also satisfactory (relative standard deviation less than 15 %). The detection limits are also accepta…
The toxicity and concentrations of PAHs in creosote-contaminated lake sediment
1999
Sediment samplers, divided into three layers (0 – 10, 10 – 20 and 20 – 30 cm), were collected from 16 sites in Lake Jamsanvesi, Central Finland. The acute toxicity of pore waters and elutriates (sediment + water 1:4 v/v) were studied by bioluminescence inhibition test and by immobilisation of water fleas (Daphnia magna Straus). Concentrations of polycyclic aromatic hydrocarbons (PAHs) in sediments and elutriates were measured by gas chromatography using flame ionization detection (GC/FID). The highest total PAH concentration was 3.3 mg/g dry weight in the sediment and up to 1.7 mg/l in the elutriate of the uppermost (0 – 10 cm) layer, also being the most toxic to photoluminencent bacteria, …
Levels, fingerprint and daily intake of polycyclic aromatic hydrocarbons (PAHs) in bread baked using wood as fuel
2009
Concentrations, fingerprint and daily intake of 16 PAHs in 15 bread samples baked using wood as fuel are examined in this work. Analysis was performed by GC/MS after saponification of the samples and clean up of the extract. The total concentration of the 16 analytes varies from 6 to 230 microg/kg on dry weight (d.w.). The better extraction procedure was estimated by analyzing test-samples and using different extraction methods. Additionally, for every analyzed sample, the extraction yield has been determined by the use of surrogate standards. Extraction yields were never less than 77% and in most cases almost 100%. The profiles of PAHs (percentage) are similar for all the analyzed samples …
The miniaturised emission chamber system and home-made passive flux sampler studies of monoaromatic hydrocarbons emissions from selected commercially…
2017
Abstract The estimation of the emission rate of organic compounds released from various types of indoor materials can be performed using stationary environmental test chambers (ETC) classified as ex-situ methods or small-scale portable analytical devices based on the use of passive technique at the stage of analytes sampling from the gaseous phase (in-situ methods). The paper presents results of emissions of selected organic compounds from the monoaromatic hydrocarbons group (benzene, toluene, ethylbenzene, p,m-xylene and styrene) emitted from the surfaces of various types of commercially-available floor coverings and the underlay made of polyurethane foam which might be installed indoors u…
Design, characterization and comparison of materials based on β and γ cyclodextrin covalently connected to microporous silica for environmental analy…
2018
Abstract Determination of organic pollutants in environmental samples presents great difficulties due to the lack of sensitivity and selectivity in many of the existing analytical methods. In this work, the efficiency of materials based on silica structures containing bounded γ-cyclodextrin has been evaluated to determinate phenolic compounds and polycyclic aromatic hydrocarbons in air and water samples, respectively, in comparison with materials made of β-cyclodextrin. According to the results obtained for the material characterization, the new γ-cyclodextrin solid phase does not apparently present any porosity when used in air samples, but it has been shown to work efficiently for the pre…
Phytoremediation of polyaromatic hydrocarbons, anilines and phenols
2002
International audience; Phytoremediation technologies based on the combined action of plants and the microbial communities that they support within the rhizosphere hold promise in the remediation of land and waterways contaminated with hydrocarbons but they have not yet been adopted in large-scale remediation strategies. In this review plant and microbial degradative capacities, viewed as a continuum, have been dissected in order to identify where bottle-necks and limitations exist. Phenols, anilines and polyaromatic hydrocarbons (PAHs) were selected as the target classes of molecule for consideration, in part because of their common patterns of distribution, but also because of the urgent …
Sensitive determination of polycyclic aromatic hydrocarbons in water samples using monolithic capillary solid-phase extraction and on-line thermal de…
2011
A methacrylate-based monolithic capillary column has been evaluated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. For this purpose, the monolyte was in situ synthesized in a 6cm×0.32mm id fused-silica capillary. The microextraction unit was fitted to a micro-HPLC pump to pass 10mL of sample. The isolated pollutants were eluted by means of 10μL of methanol, the organic phase being directly collected in a specific interface that can be fitted to the injection port of the gas chromatograph without modification. The interface allows the on-line thermal desorption of the PAHs, avoiding the dilution and providing enough sensitivity to reach …