Search results for "Artifact"

showing 10 items of 193 documents

MetProc: Separating Measurement Artifacts from True Metabolites in an Untargeted Metabolomics Experiment

2019

High-throughput metabolomics using liquid chromatography and mass spectrometry (LC/MS) provides a useful method to identify biomarkers of disease and explore biological systems. However, the majority of metabolic features detected from untargeted metabolomics experiments have unknown ion signatures, making it critical that data should be thoroughly quality controlled to avoid analyzing false signals. Here, we present a postalignment method relying on intermittent pooled study samples to separate genuine metabolic features from potential measurement artifacts. We apply the method to lipid metabolite data from the PREDIMED (PREvención con DIeta MEDi-terránea) study to demonstrate clear remova…

0301 basic medicinePooled QC sampleComputer scienceComputational biology01 natural sciencesBiochemistryArticle03 medical and health sciencesMetabolomicsTandem Mass SpectrometryMetabolomicsUntargeted metabolomics010401 analytical chemistryGeneral ChemistryPotential measurementMeasurement artifactLipidsPredimed0104 chemical sciencesR package030104 developmental biologyUntargeted metabolomicsMetabolomeArtifactsMETABOLIC FEATURESBiomarkersMissing patternChromatography LiquidJournal of Proteome Research
researchProduct

Business Process Management in Financial and Non-Financial Institutions: Payment Process Modelling in Financial Flows Management

2017

Business process management is a progressively developing area of science, which is seen as the most modern and forward-looking innovative. Modern business operations remain highly dependent on IT solutions to steer the processes. Business process management solutions have been the clue for easing daily business operations. IT solutions have actively penetrated the working environment in all areas of business, especially the financial sector. It is beyond to imagine modern financial markets and institutions without IT software support. Not only billing, calculation and payment processes, even stock pricing, market analysis and risk monitor tools are fully computerized through business proce…

060201 languages & linguisticsFinanceBusiness processArtifact-centric business process modelbusiness.industry06 humanities and the arts02 engineering and technologyBusiness process modelingBusiness modelBusiness transformationBusiness process management0602 languages and literatureBusiness analysis0202 electrical engineering electronic engineering information engineeringFinancial analysis020201 artificial intelligence & image processingBusinessINTERNATIONAL JOURNAL OF MANAGEMENT SCIENCE AND BUSINESS ADMINISTRATION
researchProduct

Enhanced field-of-view integral imaging display using multi-Köhler illumination.

2014

A common drawback in 3D integral imaging displays is the appearance of pseudoimages beyond the viewing angle. These pseudoimages appear when the light rays coming from each elemental image are not passing through the corresponding microlens, and a set of barriers must be used to avoid this flipping effect. We present a pure optical arrangement based on Köhler illumination to generate these barriers thus avoiding the pseudoimages. The proposed system does not use additional lenses to project the elemental images, so no optical aberrations are introduced. As an added benefit, Köhler illumination provides a higher contrast 3D display. This work was supported in part by the Plan Nacional I + D …

3-D displayslight raysField of viewStereo displaySensitivity and SpecificityOpticsImaging Three-DimensionalImage Interpretation Computer-AssistedKöhler illuminationLightingviewing angleoptical arrangementPhysicsMicrolensIntegral imagingbusiness.industryReproducibility of ResultsViewing angleImage EnhancementRayAtomic and Molecular Physics and Opticsintegral imagingLight intensity3D integral imagingfield of viewselemental imagesbusinessArtifactsAlgorithmsOptics express
researchProduct

Adaptive scheduling of acceleration and gyroscope for motion artifact cancelation in photoplethysmography

2022

Background and objective: Recently, various algorithms have been introduced using wrist-worn photo-plethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG.Methods: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally a…

Adaptive motion artifact reference selectionInstantaneous heart rate (HR)Gyroscope signalAccelerationSignal Processing Computer-AssistedHealth InformaticsSettore ING-INF/01 - ElettronicaComputer Science ApplicationsAcceleration signalMotionHeart RateSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaReflectance-type photoplethysmography (PPG)PhotoplethysmographyArtifactsAlgorithmsSoftwareComputer Methods and Programs in Biomedicine
researchProduct

Systematic review on spheroids from adipose‐derived stem cells: Spontaneous or artefact state?

2022

Three-dimensional (3D) cell cultures represent the spontaneous state of stem cells with specific gene and protein molecular expression that are more alike the in vivo condition. In vitro two-dimensional (2D) cell adhesion cultures are still commonly employed for various cellular studies such as movement, proliferation and differentiation phenomena; this procedure is standardized and amply used in laboratories, however their representing the original tissue has recently been subject to questioning. Cell cultures in 2D require a support/substrate (flasks, multiwells, etc.) and use of fetal bovine serum as an adjuvant that stimulates adhesion that most likely leads to cellular aging. A 3D envi…

Adipose TissuePhysiologySpheroids CellularStem Cells3D cultures adipose stem cells biomaterials hanging drop spheroids spinner flaskClinical BiochemistryAdipocytesCell Culture TechniquesCell BiologyArtifactsJournal of Cellular Physiology
researchProduct

Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

2000

This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal – not diffuse – airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six o…

AdultLung DiseasesMalemedicine.medical_specialtyAdolescentHigh resolutionSeverity of Illness IndexPulmonary function testingHumansMedicineRadiology Nuclear Medicine and imagingLung volumesProspective StudiesAgedNeuroradiologyAged 80 and overLungbusiness.industryRespirationUltrasoundGeneral MedicineNormal lung functionMiddle AgedRespiratory Function TestsLung densitymedicine.anatomical_structureFemaleRadiologyBlood Gas AnalysisArtifactsTomography X-Ray ComputedbusinessEuropean Radiology
researchProduct

Dysfunctional cortical inhibition in adult ADHD: neural correlates in auditory event-related potentials.

2013

In recent times, the relevance of an accurate diagnosis of attention-deficit/hyperactivity disorder (ADHD) in adults has been the focus of several studies. No longer considered a pathology exclusive to children and adolescents, and taking into account its social implications, developing enhanced support tools for the current diagnostic procedure becomes a priority. Here we present a method for the objective assessment of ADHD in adults using chirp-evoked, paired auditory late responses (ALRs) combined with a two-dimensional ALR denoising scheme to extract correlates of intracortical inhibition. Our method allows for an effective single-sweep denoising, thus requiring less trials to obtain r…

AdultMaleAuditory eventDysfunctional familyObjective assessmentDevelopmental psychologyYoung AdultEvent-related potentialHumansCerebral CortexNeural correlates of consciousnessGeneral NeuroscienceElectroencephalographyNeural InhibitionSignal Processing Computer-AssistedMiddle AgedAcoustic StimulationAttention Deficit Disorder with HyperactivityAuditory PerceptionEvoked Potentials AuditoryIntracortical inhibitionFemaleObjective informationCortical inhibitionPsychologyArtifactsNeuroscienceJournal of neuroscience methods
researchProduct

Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods

2015

Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To fur…

AdultMaleComputer scienceCognitive Neurosciencecerebral blood flowPartial volumePerfusion scanningImage processingSignal-To-Noise RatioYoung AdultImage Processing Computer-Assistedspin labelingHumansreproducibilityImage resolutionReproducibilitySpatial filterbusiness.industrymultiphase pseudo-continuous arterialBrainReproducibility of ResultsSite-directed spin labelingImage EnhancementMagnetic Resonance Imagingarterial spin labelingNeurologyCerebral blood flowArterial spin labelingFemaleSpin Labelsperfusion MRIArtifactsNuclear medicinebusinesstest–retestBiomedical engineeringNeuroImage
researchProduct

Assessment of the distal anastomosis of coronary artery bypass grafts with a 2D T2-weighted turbo spin echo sequence and correlation to conventional …

2005

Abstract Objective The aim of the study was to evaluate the patensies of the distal anastomoses of coronary artery bypass grafts and to detect graft stenoses and occlusions with a magnetic resonance (MR) spin echo sequence. Patients and methods One hundred and eighty-five patients with 481 distal anastomoses were examined with a 1.5 T MR scanner and coronary angiography. A 2-dimensional T2-weigthed breath-hold half-Fourier acquisition single-shot turbo spin echo sequence (Haste) was performed. All images were evaluated independently by a radiologist and cardiologist and compared to the conventional coronary angiography. The observers were blinded to the coronary angiography findings, but in…

AdultMaleCoronary angiographymedicine.medical_specialtyAnastomosisCoronary AngiographySensitivity and SpecificitymedicineHumansSaphenous VeinCoronary Artery BypassVascular PatencyAgedDistal anastomosisSequence (medicine)Aged 80 and overObserver Variationmedicine.diagnostic_testEcho-Planar Imagingbusiness.industryAnastomosis SurgicalCoronary StenosisMagnetic resonance imagingMiddle AgedImage EnhancementTreatment Outcomemedicine.anatomical_structureCirculatory systemSpin echoPatient ComplianceFemaleRadiologyArtifactsCardiology and Cardiovascular MedicinebusinessArteryInternational Journal of Cardiology
researchProduct

Suppression of the cardiac electric field artifact from the heart action evoked potential

2006

The study of heart action-related brain potentials is strongly disrupted by the presence of an inherent cardiac electric artifact. The hypothesis is presented that most of the electric current coupled to the cardiac field surrounds the skull and flows through the scalp tissue without crossing the cranial cavity. This pseudo two-dimensional conduction model contrasts with the volumetric conduction of the brain electrical activity, and this property is exploited to cancel the cardiac electric artifact. QRS loop vector-cardiographic projections on saggital planes were recorded in 11 healthy subjects in the head and neck areas. Comparative analysis of the projection eccentricities, estimated by…

AdultMaleField (physics)Biomedical EngineeringQRS complexElectric fieldCranial cavitymedicineHumansEvoked potentialEvoked PotentialsPhysicsArtifact (error)SkullElectric ConductivityElectroencephalographyHeartSignal Processing Computer-AssistedMiddle AgedComputer Science ApplicationsAmplitudemedicine.anatomical_structureFemaleElectric currentArtifactsBiomedical engineeringMedical and Biological Engineering and Computing
researchProduct