Search results for "Artificial"
showing 10 items of 7394 documents
Strength Training: Single Versus Multiple Sets
1999
Tackling the Problem of Data Imbalancing for Melanoma Classification
2016
Comunicació de congrés presentada a: 3rd International Conference on Bioimaging, BIOIMAGING 2016 - Part of 9th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2016, Roma, Italy Malignant melanoma is the most dangerous type of skin cancer, yet melanoma is the most treatable kind of cancer when diagnosed at an early stage. In this regard, Computer-Aided Diagnosis systems based on machine learning have been developed to discern melanoma lesions from benign and dysplastic nevi in dermoscopic images. Similar to a large range of real world applications encountered in machine learning, melanoma classification faces the challenge of imbalanced data, where …
A prospective analysis of the injury incidence of young male professional football players on artificial turf
2016
Background: The effects of synthetic surfaces on the risk of injuries is still debated in literature and the majority of published data seems to be contradictory. For such reasons the understanding of injury incidence on such surfaces, especially in youth sport, is fundamental for injury prevention. Objectives: The aim of this study was to prospectively report the epidemiology of injuries in young football players, playing on artificial turfs, during a one sports season. Patients and Methods: 80 young male football players (age 16.1 ± 3.7 years; height 174 ± 6.6 cm; weight 64.2 ± 6.3 kg) were enrolled in a prospective cohort study. The participants were then divided in two groups; the first…
Editorial for the Special Issue “Frontiers in Spectral Imaging and 3D Technologies for Geospatial Solutions”
2019
This Special Issue hosts papers on the integrated use of spectral imaging and 3D technologies in remote sensing, including novel sensors, evolving machine learning technologies for data analysis, and the utilization of these technologies in a variety of geospatial applications. The presented results showed improved results when multimodal data was used in object analysis.
Influence of spurious dilution and hyperglycemia on erythrocytes and platelets evaluated with two different hematological analyzers
2015
The integrity of whole blood samples may be compromised by suboptimal collection practices. Therefore, we investigated the influence of spurious hyperglycemia on erythrocytes and platelets, assessed with two hematological analyzers using optical or impedance technique. Three K2EDTA blood specimens were collected from 12 healthy subjects, pooled and divided into four aliquots. The first aliquot was left untreated (glucose concentration 4.4 mmol/L), whereas scalar amounts of standard 5% glucose solution were added to the remaining, generating glucose contamination of 5% (19.2 mmol/L), 10% (33 mmol/L) and 20% (62 mmol/L). Hematological testing was then performed using Siemens Advia 2120 and Sy…
Pharmacological Therapy in Children with Atrial Fibrillation and Atrial Flutter
2008
Heart rhythm disorders in children are not different, on electrocardiographic trace, from heart rhythm disorders in adults with the exception of incidence which is different according to the age. Paticularly, atrial flutter (FlA) and fibrillation (FA) are very uncommon arrhythmias in the general pediatric population. Generally atrial fibrillation and atrial flutter, in our experience, is a temporary heart rhythm disturbance connected to specifical and resovable reasons with the exception of Fontains surgical correction of congenital heart diseases or cardiopathies with dilatation of both atria. Presenting symptoms, symptom history (e.g., frequency, duration, and severity), risk assessment, …
A system for the automatic measurement of the nuchal translucency thickness from ultrasound video stream of the foetus
2013
Nowadays the measurement of the nuchal translucency thickness is being used as part of routine ultrasound scanning during the end of the first trimester of pregnancy, for the screening of chromosomal defects, as trisomy 21. Currently, the measurement is being performed manually by physicians. The measurement can take a long time for being accomplished, needs to be performed by highly skilled operators, and is prone to errors. Semi-automated methods requires that the user manually selects a region of the image containing the nuchal translucency, procedure that is somewhat time consuming. In this paper we present a complete system prototype that is able to perform the measurement of the nucha…
Hyperhomocysteinemia in hemodialysis patients: Is it a risk factor for cardiovascular disease?
2005
A Semi-automatic Multi-seed Region-Growing Approach for Uterine Fibroids Segmentation in MRgFUS Treatment
2013
Fibroids are benign tumors growing in the uterus. Most of fibroids do not require treatment unless they are causing symptoms. Traditional surgery treatments, like myomectomy and hysterectomy, are very invasive therapeutic approaches which not always preserves reproductive potential of the woman. MRgFUS, performed with Insightec ExAblate 2100 equipment, is a new and noninvasive technique for uterine fibroids treatment, not requiring hospitalization and recovery time for patients. An initial assessment of MRgFUS treatment is made by computing the ablated volume of uterine fibroid. In this paper a semi-automatic approach, based on region-growing segmentation technique, is proposed. The impleme…
Multimodality 3-dimensional volumetric ultrasound in obstetrics and gynecology with an emphasis in HDlive technique.
2013
HDlive (high-definition live or real-time US), a new ultrasound software, combines a movable virtual adjustable light source in a software that calculates the proportion of light reflecting through surface structures, depending on light direction. The light source can be manually positioned to illuminate the desired area of interest. The ultrasound technician can control light intensity to create shadows that enhance image quality. HDlive is an innovation that will render even more realistic images of fetal anatomy and of gynecologic lesions. The full potential of this new technology is yet to be determined and deserves scientific evaluation.