Search results for "Astigmatism"

showing 10 items of 91 documents

Astigmatism in infancy and childhood.

2000

ABSTRACT Purpose: To evaluate the prevalence of astigmatism In infancy and childhood In a Spanish population. Methods: A total of 478 children with astigmatism from Valencia Province, Spain were examined. The patients, ranging in age from 2-1 2 years, were classified into groups according to age. Astigmatism error and axis orientation were determined using noncyclopeglc retlnoscopy over each eye. Results: The overall prevalence of astigmatism (5=1.00 diopter of cylinder) decreased In relation to increasing age from 44.3% to 5.2%. The prevalence of against-the-rule astigmatism decreased from 61.5% (at 2 years) to 33.4% (at 12 years), with-the-rule astigmatism increased In prevalence from 23.…

Malemedicine.medical_specialtyPediatricsRefractive errorEye diseaseAstigmatismVision disorderAge DistributionEpidemiologymedicinePrevalenceHumansSex DistributionChildDioptreRetinoscopymedicine.diagnostic_testbusiness.industryAstigmatismGeneral Medicinemedicine.diseaseOphthalmologyEl NiñoSpainChild PreschoolPediatrics Perinatology and Child HealthOptometryFemalemedicine.symptombusinessJournal of pediatric ophthalmology and strabismus
researchProduct

Refractive changes in nuclear, cortical and posterior subcapsular cataracts. Effect of the type and grade

2015

Purpose: To determine the effect of main morphological types and grades of age-related cataracts on refractive error. Methods: We measured 276 subjects with optical compensation prior to the development of cataract. We evaluated 224 eyes with nuclear cataract, 125 with cortical cataract, and 103 with posterior subcapsular (PSC) cataract classified with LOCSIII. We measured visual acuity (VA) with their spectacles and best-corrected visual acuity (BCVA) with chart in decimal scale to obtain the optimal compensation with cataract. We evaluated the differences between compensations. Results: A significant myopic shift was observed in nuclear cataract from low to mild grade (p = 0.031), the sam…

Malemedicine.medical_specialtyRefractive errorNuclear cataractVisual acuitygenetic structuresCortical cataractVisual AcuityCatarataAstigmatismCataractContrast SensitivityCorticallcsh:OphthalmologyCataractsOphthalmologyLens CrystallineOptical compensationMyopiamedicineHumanslcsh:QC350-467Subcapsular posteriorNuclearIn patientCompensación ópticaAgedAged 80 and overAnalysis of Variancebusiness.industryAstigmatismLens Nucleus CrystallineLens Cortex CrystallineMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSurgeryPosterior subcapsularlcsh:RE1-994FemaleOriginal Articlesense organsPosterior subcapsular cataractmedicine.symptombusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery.

2009

To compare toric intraocular lens (IOL) implantation with paired opposite clear corneal incisions (OCCIs) for astigmatism correction in patients having cataract surgery.Ophthalmology Service, Donostia Hospital, San Sebastián, Spain.This randomized prospective clinical study comprised eyes with more than 1.00 diopter (D) of preexisting corneal astigmatism. One group had AcrySof toric IOL implantation and the other, paired 2.75 mm/3.20 mm OCCIs in the steep axis with spherical IOL implantation. Uncorrected (UCVA) and best corrected (BCVA) visual acuity, refraction, corneal and total higher-order aberrations (HOAs), photopic and mesopic contrast sensitivity, and toric IOL axis were measured 3 …

Malemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismContrast SensitivityCorneaPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraoperative ComplicationsDioptreAgedLenses IntraocularPhacoemulsificationmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyPhacoemulsificationCataract surgeryCorneal topographymedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologySurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism

1999

Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…

Malemedicine.medical_specialtyRefractive errorgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismRefraction OcularCataractCorneaHigh astigmatismLens Implantation IntraocularOphthalmologyHumansPolymethyl MethacrylateMedicineDioptreLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismCorneal TopographyPhacoemulsificationMiddle AgedCataract surgeryequipment and suppliesmedicine.diseaseeye diseasesSensory SystemsSurgeryToric lensOphthalmologySurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual Performance of a Multifocal Toric Soft Contact Lens

2012

PURPOSE To evaluate the visual performance of the Proclear multifocal toric contact lens (CL; CooperVision, US) for both presbyopia and astigmatism correction. METHODS In this crossover study design, 20 presbyopic subjects with astigmatism were fitted in a random order with either Proclear multifocal toric CL or Proclear toric single vision distance CL (DCL) combined with reading spectacles. After 1 month, high-contrast distance visual acuity, near high-contrast visual acuity, distance contrast sensitivity (CS) under photopic and mesopic conditions without and with glare, near CS, defocus curve, and stereopsis were measured. Subjects were then refitted with the alternative correction, and t…

Malemedicine.medical_specialtyVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectVisual AcuityAstigmatismRefraction OcularOphthalmologymedicineHumansContrast (vision)AgedMathematicsmedia_commonCross-Over StudiesGlare (vision)Equipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicRefractive Errorsmedicine.diseaseeye diseasesContact lensOphthalmologyFemalemedicine.symptomOptometryPhotopic visionOptometry and Vision Science
researchProduct

Refractive Lens Exchange with Foldable Toric Intraocular Lens

2009

To assess visual and refractive outcomes, and rotational stability after refractive lens exchange (RLE) with toric intraocular lens (IOL) implantation to correct ametropia and preexisting astigmatism.Prospective, nonrandomized, observational case series (self-controlled).This prospective, nonrandomized, and self-controlled study included 32 eyes of 19 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having RLE with AcrySof Toric IOL implantation (Alcon Laboratories Inc, Fort Worth, Texas, USA). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), refractive sphere, and keratometric and refractive cylinder were recorded preoperatively …

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensVisual phenomenaAstigmatismRefractive lens exchangeRefraction OcularLens Implantation IntraocularSurveys and QuestionnairesOphthalmologyMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesOphthalmologyAlcon LaboratoriesEyeglassesPatient SatisfactionOptometryFemalesense organsmedicine.symptombusinessCorneal astigmatismAmerican Journal of Ophthalmology
researchProduct

Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation

2009

Purpose: To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation. Methods: Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (⩽1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery. Results: Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42±1.36 se…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentPopulationVisual AcuityIntraocular lensAstigmatismOpticsLens Implantation IntraocularOphthalmologymedicineHumanseducationDioptreLenses IntraocularDepth PerceptionVision Binoculareducation.field_of_studyPhacoemulsificationbusiness.industryPresbyopiaPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyHyperopiaFemaleSurgerymedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Astigmatism among myopics and its changes from childhood to adult age: a 23‐year follow‐up study

2014

Purpose To study the prevalence of and changes in astigmatism from the onset of myopia at school age. Methods Two hundred and forty myopic schoolchildren (mean age 10.9 years), with no previous spectacles, were recruited during 1983–1984 to a randomized 3-year clinical trial of bifocal treatment of myopia. Three annual examinations with subjective cycloplegic refraction were performed for 237–238 subjects. Subsequent examinations were performed at the mean ages of 23.2 and 33.9 years for 178 and 163 subjects, and the last examination, including data from prescriptions of different ophthalmologists, for 32 subjects. Corneal topography was studied at baseline, at the 3-year follow-up and at t…

Malemedicine.medical_specialtyprevalenceVisual AcuityAstigmatismRefraction OcularAdult ageaxiscorneaOphthalmologyCorneachangemedicineHumansmyopiaChildFinlandSchool age childmedicine.diagnostic_testbusiness.industryFollow up studiesCorneal TopographyMean ageta3142General Medicinemedicine.diseaseCorneal topographyta3125Axial Length EyeOphthalmologyEyeglassesastigmatismmedicine.anatomical_structureDisease ProgressionFemalesense organsbusinesspolar valueCorneal astigmatismFollow-Up StudiesActa Ophthalmologica
researchProduct

Effect of even and odd-order aberrations on the accommodation response

2017

Aim To investigate the potential effect that odd and even-order monochromatic aberrations may have on the accommodation response of the human eye. Methods Eight healthy subjects with astigmatism below 1 D, best corrected visual acuity 20/20 or better and normal findings in an ophthalmic examination were enrolled. An adaptive optics system was used in order to measure the accommodation response of the subjects' eyes under different conditions: with the natural aberrations being present, and with the odd and even-order aberrations being corrected. Three measurements of accommodation response were monocularly acquired at accommodation demands ranging from 0 to 4 D (0.5 D step). Results The acc…

Ophthalmic examinationAstigmatism050105 experimental psychologyadaptive optics03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyClinical Researchmonochromatic aberrationsMedicine0501 psychology and cognitive sciences10. No inequalityAdaptive opticsaccommodation responseBest corrected visual acuitybusiness.industry05 social sciencesHealthy subjectsmedicine.disease960Ophthalmologymedicine.anatomical_structurelcsh:RE1-994030221 ophthalmology & optometryOptometryHuman eyeAccommodative lagbusinessAccommodationInternational Journal of Ophthalmology
researchProduct