Search results for "Attenuation coefficient"
showing 10 items of 62 documents
Measurement of the velocity and attenuation of fourth sound in helium II
1979
The velocity and the attenuation of fourth sound have been measured in liquid helium at temperatures between 0.8 K and the λ point, along the vapor pressure curve. The measurements were made using the resonance technique and the helium was contained between small pores in packed powder specimens. From the velocity, it could be determined that the sound propagates under “adiabatic” conditions. According to theory, the attenuation of fourth sound consists of two contributions: surface losses due to heat exchange with the resonator body and volume losses due to dissipative processes associated with the viscosity coefficients η and ζ3. The results of our attenuation measurements are in agreemen…
Monte Carlo calculation of dose rate distributions around 0.5 and 0.6 mm in diameter 192Ir wires
1999
Monte Carlo simulations of absolute dose rate in liquid water are presented in the form of away-along tables for 1 and 5 cm 192 Ir wires of 0.5 and 0.6 mm diameter. Simulated absolute dose rate values can be used as benchmark data to verify the calculation results of treatment planning systems or directly as input data for treatment planning. Best fit value of an attenuation coefficient suitable for use in Sievert integral-type calculations has been derived based on Monte Carlo simulation results. For the treatment planning systems that are based on the TG43 formalism we have also computed the required dosimetry parameters.
Luminescence of localized states in oxidized and fluorinated silica glass
2019
This work was supported by the Latvian Science Council Grant No lzp-2018/1-0289.
Online measurement of floc size, viscosity, and consistency of cellulose microfibril suspensions with optical coherence tomography
2021
AbstractIn this study, cellulose microfibril (CMF) suspensions were imaged during pipe flow at consistencies of 0.4%, 1.0%, and 1.6% with optical coherence tomography (OCT) to obtain images of the structure and the local velocity of the suspension. The viscosities obtained by combining pressure loss measurement with the OCT velocity data showed typical shear thinning behavior and were in excellent agreement with viscosities obtained with ultrasound velocity profiling. The structural OCT images were used to calculate the radial and the axial floc sizes of the suspension. A fit of power law to the geometrical floc size–shear stress data gave the same power law index for all consistencies, sug…
Optical propagation loss measurements in electro optical host-guest waveguides
2013
Thin organic waveguiding layers are applied more and more frequently as optical components in novel optoelectronic devices. For development of such devices it is important to know the optical properties of the used waveguides. One of the most important parameters is optical propagation loss in the waveguide. In this paper we present optical propagation loss measurements in planar electro optical waveguides using travelling fiber method. Using this method attenuation coefficient α at 633 nm as a function of chromophore concentration for the first two guiding modes in the slab waveguide was determined.
Second-harmonic generation in Langmuir–Blodgett monolayers of stilbazium salt and phenylhydrazone dyes
1988
The second-order nonlinear optical susceptibilities χ(2) of several phenylhydrazone and stilbazium salt dyes in Langmuir–Blodgett monolayers have been determined from second-harmonic-generation measurements. Three of the substances demonstrated χ(2) values greater than 10−6 electrostatic units, although two of the three did not absorb light significantly at the second-harmonic wavelength.
Optical tuning of dielectric nanoantennas for thermo-optically reconfigurable nonlinear metasurfaces
2021
We demonstrate optically tunable control of second-harmonic generation in all-dielectric nanoantennas: by using a control beam that is absorbed by the nanoresonator, we thermo-optically change the refractive index of the radiating element to modulate the amplitude of the second-harmonic signal. For a moderate temperature increase of roughly 40 K, modulation of the efficiency up to 60% is demonstrated; this large tunability of the single meta-atom response paves the way to exciting avenues for reconfigurable homogeneous and heterogeneous metasurfaces.
Determination of mass attenuation coefficient by numerical absorption calibration with Monte-Carlo simulations at 59.54 keV
2016
Abstract This study presents a numerical method in order to determine the mass attenuation coefficient of a sample with an unknown chemical composition at low energy. It is compared with two experimental methods: a graphic method and a transmission method. The method proposes to realise a numerical absorption calibration curve to process experimental results. Demineralised water with known mass attenuation coefficient ( 0.2066 cm 2 g − 1 at 59.54 keV) is chosen to confirm the method. 0.1964 ± 0.0350 cm 2 g − 1 is the average value determined by the numerical method, that is to say less than 5% relative deviation compared to more than 47% for the experimental methods.
ESR response of phenol compounds for dosimetry of gamma photon beams
2014
Abstract In the present paper we investigate the features of IRGANOX® 1076 phenols as a material for electron spin resonance (ESR) dosimetry. We experimentally analyzed the ESR response of pellets of IRGANOX® 1076 phenols irradiated with 60Co photons. The best experimental parameters (modulation amplitude and microwave power) for dosimetric applications have been obtained. The dependence of ESR signal as function of γ dose is found to be linear in the dose range studied (12–60 Gy) and the lowest measurable dose is found to be of the order of 1 Gy. The signal after irradiation is very stable in the first thirty days. From the point of view of the tissue equivalence, these materials have mass…
Time-resolved acousto-optic interaction in single-mode optical fibers: characterization of axial nonuniformities at the nanometer scale.
2014
We report on a time-resolved acousto-optic interaction technique for the detection of axial nonuniformities in single-mode fibers. It is based on the propagation of short packets of flexural acoustic waves. Small axial nonuniformities (of the order of nanometers) are detected by measuring the transmittance of the fundamental mode as a function of time. It is shown that the technique allows the detection of axial nonuniformities along sections of single-mode fiber exceeding 1 m long with spatial resolution of the order of a few centimeters.