Search results for "Auditory Threshold"
showing 10 items of 33 documents
Integration of acoustical information in the perception of impacted sound sources. The role of information accuracy and exploitability.
2010
Sound sources are perceived by integrating information from multiple acoustical features. The factors influencing the integration of information are largely unknown. We measured how the perceptual weighting of different features varies with the accuracy of information and with a listener’s ability to exploit it. Participants judged the hardness of two objects whose interaction generates an impact sound: a hammer and a sounding object. In a first discrimination experiment, trained listeners focused on the most accurate information, although with greater difficulty when perceiving the hammer. We inferred a limited exploitability for the most accurate hammer-hardness information. In a second r…
Gentamicin alters Akt-expression and its activation in the guinea pig cochlea
2015
Gentamicin treatment induces hair cell death or survival in the inner ear. Besides the well-known toxic effects, the phosphatidylinositol-3 kinase/Akt (PI3K/Akt) pathway was found to be involved in cell protection. After gentamicin application, the spatiotemporal expression patterns of Akt and its activated form (p-Akt) were determined in male guinea pigs. A single dose of 0.1 mL gentamicin (4 mg/ear/animal) was intratympanically injected. The auditory brainstem responses (ABRs) were recorded prior to application and 1, 2 and 7 days afterward. At these three time points the cochleae (n=10 in each case) were removed, transferred to fixative and embedded in paraffin. Seven ears were used as u…
Otitis media with effusion in children: Cross-frequency correlation in pure tone audiometry.
2019
Different guidelines are adopted in clinics and countries to assess pure tone hearing sensitivity in children with otitis media with effusion (OME). Some guidelines specify a broad range of audiometric frequencies that must be tested and from which average thresholds determined, while others leave test frequencies unspecified. For guidelines that suggest specific frequencies there are various pure tone frequencies and frequency ranges given. The present study investigated whether (1) a full range of audiometric frequencies is required to evaluate hearing loss caused by OME in children, or if neighboring frequencies provide essentially the same threshold information, and (2) if different com…
The association of noise sensitivity with music listening, training, and aptitude
2015
After intensive, long-term musical training, the auditory system of a musician is specifically tuned to perceive musical sounds. We wished to find out whether a musician's auditory system also develops increased sensitivity to any sound of everyday life, experiencing them as noise. For this purpose, an online survey, including questionnaires on noise sensitivity, musical background, and listening tests for assessing musical aptitude, was administered to 197 participants in Finland and Italy. Subjective noise sensitivity (assessed with the Weinstein's Noise Sensitivity Scale) was analyzed for associations with musicianship, musical aptitude, weekly time spent listening to music, and the impo…
Cochlear implant users move in time to the beat of drum music.
2015
Cochlear implant users show a profile of residual, yet poorly understood, musical abilities. An ability that has received little to no attention in this population is entrainment to a musical beat. We show for the first time that a heterogeneous group of cochlear implant users is able to find the beat and move their bodies in time to Latin Merengue music, especially when the music is presented in unpitched drum tones. These findings not only reveal a hidden capacity for feeling musical rhythm through the body in the deaf and hearing impaired population, but illuminate promising avenues for designing early childhood musical training that can engage implanted children in social musical activi…
The decision process in forward-masked intensity discrimination: evidence from molecular analyses.
2009
In a two-interval forced-choice intensity discrimination task presenting a fixed increment, the level of the forward masker in interval 1 and interval 2 was sampled independently from the same normal distribution on each trial. Mean and standard deviation of the distribution were varied. Correlational analyses of the trial-by-trial data revealed different decision strategies depending on the relation between mean masker level and standard level. If the two levels were identical, listeners tended to select the interval containing the higher-level masker, behaving like an energy detector at the output of a temporal window of integration. For mean masker level higher than the standard level, m…
Low-Frequency Therapeutic Ultrasound with Varied Duty Cycle: Effects on the Ischemic Brain and the Inner Ear
2009
Sonothrombolysis is a promising modality for acute stroke treatment. In vitro data suggest a duty cycle dependence of sonothrombolytic efficacy of low-frequency applications. The aim of our study was to examine its impact on safety issues in a rat model of middle cerebral artery occlusion. Rats were exposed to transcranial 60-kHz ultrasound with varied duty cycles. To determine effects on the inner ear, the acoustic threshold was determined in additional healthy animals (acoustic evoked potentials). A short duty cycle (20%) resulted in significant adverse effects (ischemic volume, hemorrhage, functional outcome), which was not observed in longer duty cycle (80%). Continuous-wave insonation …
Sudden sensorineural hearing loss: is there a relationship between routine haematological parameters and audiogram shapes?
2016
Objective: To investigate the relationship between haematological routine parameters and audiogram shapes in patients affected by sudden sensorineural hearing loss (SSNHL). Design: A retrospective study. All patients were divided into four groups according to the audiometric curve and mean values of haematological parameters (haemoglobin, white blood cell, neutrophils and lymphocytes relative count, platelet count, haematocrit, prothrombin time, activated partial thromboplastin time, fibrinogen and neutrophil-to-lymphocite ratio) of each group were statistically compared. The prognostic role of blood profile and coagulation test was also examined. Study sample: A cohort of 183 SSNHL patient…
Temporal weights in loudness: Investigation of the effects of background noise and sound level
2019
Previous research has consistently shown that for sounds varying in intensity over time, the beginning of the sound is of higher importance for the perception of loudness than later parts (primacy effect). However, in all previous studies, the target sounds were presented in quiet, and at a fixed average sound level. In the present study, temporal loudness weights for a time-varying narrowband noise were investigated in the presence of a continuous bandpass-filtered background noise and the average sound levels of the target stimuli were varied across a range of 60 dB. Pronounced primacy effects were observed in all conditions and there were no significant differences between the temporal w…
First Experiences With the Ponto⢢ SuperPower Osseointegrated Device
2018
Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto™ Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. Th…