Search results for "Automated"
showing 10 items of 236 documents
A completely automated CAD system for mass detection in a large mammographic database.
2006
Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing secon…
Exudate-based diabetic macular edema detection in fundus images using publicly available datasets
2010
International audience; Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy. In a large scale screening environment DME can be assessed by detecting exudates (a type of bright lesions) in fundus images. In this work, we introduce a new methodology for diagnosis of DME using a novel set of features based on colour, wavelet decomposition and automatic lesion segmentation. These features are employed to train a classifier able to automatically diagnose DME through the presence of exudation. We present a new publicly available dataset with ground-truth data containing 169 patients from various ethnic groups and levels of DME. This and other two publi…
An automated image analysis methodology for classifying megakaryocytes in chronic myeloproliferative disorders
2008
This work describes an automatic method for discrimination in microphotographs between normal and pathological human megakaryocytes and between two kinds of disorders of these cells. A segmentation procedure has been developed, mainly based on mathematical morphology and wavelet transform, to isolate the cells. The features of each megakaryocyte (e.g. area, perimeter and tortuosity of the cell and its nucleus, and shape complexity via elliptic Fourier transform) are used by a regression tree procedure applied twice: the first time to find the set of normal megakaryocytes and the second to distinguish between the pathologies. The output of our classifier has been compared to the interpretati…
Photochemical-chemiliminometric determination of aldicarb in a fully automated multicommutation based flow-assembly
2004
[EN] A sensitive and fully automated method for determination of aldicarb in technical formulations (Temik) and mineral waters is proposed. The automation of the flow-assembly is based on the multicommutation approach, which uses a set of solenoid valves acting as independent switchers. The operating cycle for obtaining a typical analytical transient signal can be easily programmed by means of a home-made software running in the Windows environment. The manifold is provided with a photoreactor consisting of a 150 cm long x 0.8 mm i.d. piece of PTFE tubing coiled around a 20 W low-pressure mercury lamp. The determination of aldicarb is performed on the basis of the iron(III) catalytic minera…
Dimensions of executive functioning: Evidence from children
2003
This study investigated dimensions of executive functioning in 8- to 13-year-old children. Three tasks from the Cambridge Neuropsychological Test Automated Battery (CANTAB), two tasks from the NEPSY battery and some additional executive function (EF) tests were administered to 108 children. In line with earlier work, modest correlations among EF measures were obtained (r < .4). Both exploratory and confirmatory factor analyses yielded three interrelated factors, which resembled those obtained by Miyake et al. (2000) and which were—with some reservations—labelled Working Memory (WM), Inhibition and Shifting. Age correlated with performance on most individual EF measures as well as Shifting a…
Multispectral integral imaging acquisition and processing using a monochrome camera and a liquid crystal tunable filter
2012
This paper presents an acquisition system and a procedure to capture 3D scenes in different spectral bands. The acquisition system is formed by a monochrome camera, and a Liquid Crystal Tunable Filter (LCTF) that allows to acquire images at different spectral bands in the [480, 680]nm wavelength interval. The Synthetic Aperture Integral Imaging acquisition technique is used to obtain the elemental images for each wavelength. These elemental images are used to computationally obtain the reconstruction planes of the 3D scene at different depth planes. The 3D profile of the acquired scene is also obtained using a minimization of the variance of the contribution of the elemental images at each …
Wavelength-compensated time-sequential multiplexed color joint transform correlator
2010
We report a wavelength-compensated three-channel (RGB) joint transform correlator (JTC) for color pattern recognition using a ferroelectric liquid-crystal spatial light modulator (SLM) operating in binary pure phase modulation. We apply a previously reported time-multiplexing technique useful in creating wavelength-compensated diffraction patterns, based on the synchronization of properly scaled diffraction masks with the input wavelength selection obtained by applying a rotating RGB color-filter wheel to an Ar-Kr laser. The application of this technique to a JTC architecture permits real-time color object detection. In order to achieve a high light efficiency for the correlation process, w…
A multi-technique, micrometer- to atomic-scale description of a synthetic analogue of chukanovite, Fe-2(CO3)(OH)(2)
2014
International audience; A synthetic analogue of chukanovite Fe-2(CO3)(OH)(2) is formed during experimental work on iron-clay interactions simulating the cooling of containers in radioactive waste repositories. Despite its small size and the mixture with other minerals it is undoubtedly identified by X-Ray Diffraction, Fourier Transform Infrared Spectroscopy, Scanning Electron Microscopy and Transmission Electron Microscopy. For the first time, the structural characterisation of a synthetic chukanovite is carried out thanks to the combination of Automated Diffraction Tomography and Precession Electron Diffraction. Refinement results and comparison with literature data show that the structure…
Application of delta recycling to electron automated diffraction tomography data from inorganic crystalline nanovolumes
2013
δ Recycling is a simple procedure for directly extracting phase information from Patterson-type functions [Rius (2012). Acta Cryst. A68, 399-400]. This new phasing method has a clear theoretical basis and was developed with ideal single-crystal X-ray diffraction data. On the other hand, introduction of the automated diffraction tomography (ADT) technique has represented a significant advance in electron diffraction data collection [Kolb et al. (2007). Ultramicroscopy, 107, 507-513]. When combined with precession electron diffraction, it delivers quasi-kinematical intensity data even for complex inorganic compounds, so that single-crystal diffraction data of nanometric volumes are now availa…
Structure analysis of titanate nanorods by automated electron diffraction tomography
2011
A hitherto unknown phase of sodium titanate, NaTi3O6(OH)·2H2O, was identified as the intermediate species in the synthesis of TiO2 nanorods. This new phase, prepared as nanorods, was investigated by electron diffraction, X-ray powder diffraction, thermogravimetric analysis and high-resolution transmission electron microscopy. The structure was determined ab initio using electron diffraction data collected by the recently developed automated diffraction tomography technique. NaTi3O6(OH)·2H2O crystallizes in the monoclinic space group C2/m. Corrugated layers of corner- and edge-sharing distorted TiO6 octahedra are intercalated with Na+ and water of crystallization. The nanorods are typically …