Search results for "Automotive engineering"
showing 10 items of 483 documents
Design of a Battery/Ultracapacitor Energy Storage System for Electric Vehicle Applications
2018
The battery/ultracapacitors (UCs) integration is able to provide notable advantages in the power management of an electric vehicle (EV), in terms of capability of both high energy storage and readiness to deal with fast load variations. In order to manage the charge (or discharge) of the UCs from (or towards) a DC voltage bus, a proper bi-directional converter is required. In this paper, a bi-directional DC-DC converter in connection with a stack of UCs is described and some power simulation results are provided. The proposed converter is a B2R (buck-boost regulator) type. The load is represented by a 40kW peak power, kept for a time window of 3s, as required by the Worldwide harmonized Lig…
Ev charging station at university campus
2017
This paper faces the technical and economic challenges related to the design of a green recharge area for electric vehicles at the Campus of Palermo, Italy, with the aim of reduce both costs and pollution connected to the charging process. Based on the behaviour of the student population, the electrical load is identified and two possible solutions are evaluated to manage the peak load: an orientation of the panels increasing the power at defined time and the use of a storage system. The main strength and weakness points of two systems are investigated by taking into account the Levelized Cost of Energy (LCOE), which reaches 75.3 â¬/MWh for the orientation of panel and 103 â¬/MWh for stor…
PV System Design for Off-Grid Applications
2015
Solar photovoltaic (PV) technology has the versatility and flexibility for developing off-grid electricity system for different regions, especially in remote rural areas. While conventionally straight forward designs were used to set up off-grid PV-based system in many areas for wide range of applications, it is now possible to adapt a smart design approach for the off-grid solar PV hybrid system. A range of off-grid system configurations are possible, depending upon load requirements and their electrical properties as well as on site-specific available energy resources. The overall goal of the off-gird system design should be such that it should provide maximum efficiency, reliability and …
BCD-9 OPERATIVE VARIATOR CHARACTERIZATION FOR CVT IMPROVEMENT(BELT AND CHAIN DRIVES)
2001
Analysis Based Optimization of Human Powered Vehicle Body
2015
The human powered vehicle market is not only a larger market per unit than the automotive market, but it is one in growth. The main product of this market is the classical bicycle, which is familiar around the globe, but mainly in the urban environment. The bicycle, which in this paper will be considered a human powered vehicle, is slowly gaining ground in the field of urban transportation solutions. This paper analyzes the possibility of optimizing the body of a human powered vehicle recumbent tricycle through continuous fluid dynamics. The vehicle is already designed and built, and is fully functional. The body of the vehicle comes as a necessity to give the operator protection from the e…
Method for improving the contouring accuracy for CNC profiling machines at the shop floor level
2009
Computer Numerically Controlled (CNC) laser cutting machines are capable of producing high-quality precise parts. However, as cutting speeds is increased, in order to achieve higher productivity, the accuracy of the parts is affected. In order to improve the contouring accuracy of these machines, a simple straight-forward joint simulation and experimental strategy is proposed. The position controllers within the feed drives are considered the key factor in improving the dynamic behavior and consequently the contouring accuracy of a CNC laser cutting machine at the shop floor level.
Smart Cooling System for Milk Transportation in Rural Areas
2021
In the dairy industry, road milk tankers transport milk from one location to another. The milk inside the tanker needs to be kept between 3–5 °C to ensure that the quality of milk is always preserved. The tanker needs to be kept running at all time with the case of sufficient energy being continuously supplied to the cooling unit. The source of energy normally used for this application is a typical generator which needs fuel to operate. This is expensive and is not environmentally friendly. To address this problem, generator as a source of energy needs to be replaced by solar energy to lower the costs associated with cooling of the tanker. In this research a small scale solar powered intell…
Load match and grid interaction optimization of a net zero energy building through electricity storage: An Italian case-study
2016
The study aims at applying of Load Match and Grid Interaction indexes to a Net Zero Energy Building in order to optimize the performances of its energy systems. The case study is a modular prefabricated house that uses solar energy (photovoltaic) and natural gas (Fuel Cell) as energy sources and equipped with an Energy Management System addressing the optimal energy use.
Method for size optimisation of large wind–hydrogen systems with high penetration on power grids
2013
Wind power generation is growing rapidly in many locations around the world. Power systems are able to absorb large amounts of wind capacity, but operational problems arise when the wind power penetration becomes high. Such factors as voltage dips, frequency variations, low power system stability, low reactive power and power flow imbalances reduce the economic value and represent a barrier to the unlimited development of wind energy. Hydrogen production from wind power that is not matched with hourly electricity demand appears to be an attractive storage option capable of providing a balancing service to the electricity generators and suppliers for mitigation of the negative impacts due to…
An optimal operating strategy for combined RES–based Generators and Electric Storage Systems for load shifting applications
2013
This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an i…