Search results for "Axial Length"

showing 10 items of 32 documents

Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT

2021

Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…

Adultmedicine.medical_specialtyBiometryAnterior ChamberSignificant negative correlationPositive correlationSwept-source Fourier domainCorrelationLens thicknessOphthalmologyLens CrystallineHumansMedicineOptical coherence tomographybusiness.industrySpur-to-spurReproducibility of ResultsMean ageAxial lengthWhite-to-whiteMiddle AgedClinical routineCrystalline lens riseAxial Length Eyemedicine.anatomical_structureLens (anatomy)Original ArticlebusinessTomography Optical CoherenceOptometryJournal of Optometry
researchProduct

Ocular biometry with swept-source optical coherence tomography

2020

This study aimed to summarize the outcomes reported when swept-source optical coherence tomography (SS-OCT) is used for ocular biometry. A literature search was performed to identify publications reporting clinical outcomes of patients measured with commercial SS-OCT. Twenty-nine studies were included in this review. A comprehensive analysis of the available data was performed, focusing on parameters used for intraocular lens (IOL) power calculation in cataract surgery, including keratometry, central corneal thickness, white-to-white distance, anterior chamber depth, lens thickness, axial length, IOL power, and pupil diameter. Different metrics for repeatability, reproducibility, and agreem…

Biometrygenetic structuresAnterior Chambermedicine.medical_treatmentIntraocular lensCataractlaw.invention03 medical and health sciences0302 clinical medicineOptical coherence tomographyLens thicknesslawHumansMedicineLenses IntraocularReproducibilitymedicine.diagnostic_testKeratometerbusiness.industryReproducibility of ResultsGold standard (test)RepeatabilityCataract surgeryeye diseasesSensory SystemsAxial Length EyeOphthalmology030221 ophthalmology & optometryOptometrySurgerysense organsbusinessTomography Optical Coherence030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Evaluation of 6 biometers based on different optical technologies

2021

This study shows that optical biometers based on different technologies provide repeatable measurements for different ocular parameters and, when compared, statistically significant differences between them were found when measuring most parameters.

Biometrygenetic structuresKeratometerAnterior ChamberCoefficient of variationReproducibility of ResultsArticlesRepeatabilityeye diseasesSensory Systemslaw.inventionCorneaAxial Length EyeOphthalmologylawStatisticsHumansSurgerysense organsProspective StudiesTomography Optical CoherenceMathematicsJournal of Cataract and Refractive Surgery
researchProduct

Axial Length and Anterior Segment Alterations in Former Preterm Infants and Full-Term Neonates Analyzed With Scheimpflug Imaging.

2017

Purpose To compare the axial length and anterior segment alterations in preterm infants with and without retinopathy of prematurity with those of full-term infants. Methods The Wiesbaden Prematurity Study investigated 503 participants of former gestational age ≤32 weeks and gestational age ≥37 weeks now being aged 4 to 10 years. This study included 485 participants in the prospective controlled cross-sectional, hospital-based study with successful Pentacam Scheimpflug imaging. Anterior segment parameters, axial length measurements, and associated factors were analyzed. Results Corneal thickness did not differ between former preterm and full-term infants. Significant differences were found b…

Diagnostic ImagingMalePediatricsmedicine.medical_specialtyCorneal PachymetryTerm BirthBirth weightVisual AcuityGestational AgeAstigmatismRefraction Ocular03 medical and health sciences0302 clinical medicineAnterior Eye SegmentMedicineBirth WeightHumansProspective StudiesCorneal pachymetryChildFull Termmedicine.diagnostic_testbusiness.industryGestational ageRetinopathy of prematurityInfant Low Birth Weightmedicine.diseaseRefractive ErrorsOphthalmologyLow birth weightAxial Length EyeCross-Sectional Studies030221 ophthalmology & optometryTerm BirthFemalemedicine.symptombusiness030217 neurology & neurosurgeryInfant PrematureCornea
researchProduct

Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry

2021

PURPOSE To analyze the agreement of the predicted intraocular lens (IOL) power obtained with ANTERION, IOLMaster 700 and Pentacam AXL biometers. METHODS We calculated the monofocal and trifocal IOL power using the SRK/T, Haigis, Barrett Universal II and Hoffer Q formulas for 106 eyes. IOL power agreement between devices was evaluated using the Bland-Altman method. RESULTS We found significant differences between biometers comparisons (p  0.05), with the same outcomes for medium- and long-eyes. No significant differences were found using the SRK/T, Haigis, or Hoffer Q formulas for short-eyes (p > 0.1). However, Barrett Universal II formula produced significant differences (p < 0.05) and thes…

Lenses IntraocularPhysicsmedicine.medical_specialtyBiometrymedicine.diagnostic_testmedicine.medical_treatmentLimits of agreementScheimpflug principleBiomedical EngineeringReproducibility of ResultsIntraocular lensGeneral MedicineAxial Length EyeInterferometryOptical coherence tomographyIntraocular lens powerPartial coherence interferometryOphthalmologymedicineHumansOptical biometerSurgeryTomography Optical CoherenceRetrospective StudiesExpert Review of Medical Devices
researchProduct

Graphic representation of data resulting from measurement comparison trials in cataract and refractive surgery.

2003

* BACKGROUND AND OBJECTIVES: The evaluation of new diagnostic measurement devices allows intraindividual comparison with an established standard method. However, reports in journal articles often omit the adequate incorporation of the intraindividual design into the graphic representation. * PATIENTS AND METHODS: This article illustrates the drawbacks and the possible erroneous conclusions caused by this misleading practice in terms of recent method comparison data resulting from axial length measurement in 220 consecutive patients by both applanation ultrasound and partial coherence interferometry. * RESULTS: Graphic representation of such method comparison data should be based on boxplots…

LightConcordancemedicine.medical_treatmentCataract ExtractionDiagnostic Techniques Ophthalmologicalcomputer.software_genreEyeCataractOpticsRefractive surgeryComputer GraphicsMedicineHumansIntraindividual comparisonProspective StudiesGraphicsRepresentation (mathematics)Mathematical ComputingUltrasonographybusiness.industryAxial lengthRefractive ErrorsRefractive Surgical ProceduresOphthalmologyInterferometryMethod comparisonPartial coherence interferometryData Interpretation StatisticalArtificial intelligencebusinesscomputerNatural language processingOphthalmic surgery, lasersimaging : the official journal of the International Society for Imaging in the Eye
researchProduct

Agreement between intraoperative anterior segment spectral-domain OCT and 2 swept-source OCT biometers.

2021

Purpose: To evaluate the agreement of different biometric parameters obtained using intraoperative spectral-domain optical coherence tomography (SD-OCT) and two swept-source optical coherence tomog...

MaleBiometryCorneal PachymetryPhysics::Medical PhysicsBiomedical EngineeringSpectral domain030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineOpticsOptical coherence tomographyAnterior Eye SegmentLens CrystallinemedicineHumansAgedPhysicsAged 80 and overmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineCoherence (statistics)Middle AgedAxial Length EyeOptical biometerSurgeryFemalebusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Association of ocular, cardiovascular, morphometric and lifestyle parameters with retinal nerve fibre layer thickness.

2017

BACKGROUND Glaucoma is a neurodegenerative disease, leading to thinning of the retinal nerve fibre layer (RNFL). The exact influence of ocular, cardiovascular, morphometric, lifestyle and cognitive factors on RNFL thickness (RNFLT) is unknown and was analysed in a subgroup of the Gutenberg Health Study (GHS). METHODS Global peripapillary RNFLT was measured in 3224 eyes of 1973 subjects (49% female) using spectral-domain optical coherence tomography (SD-OCT). The association of age, sex, ocular, cardiovascular, morphometric, lifestyle and cognitive factors on RNFLT was analysed using Pearson correlation coefficient and fitting a linear mixed model. RESULTS In the univariable analysis highest…

MaleHomocysteineEye Diseasesgenetic structuresGlaucomalcsh:MedicineBlood PressureOtologyVascular MedicineDiagnostic Radiologychemistry.chemical_compoundTinnitus0302 clinical medicineNerve FibersAnimal CellsMedicine and Health SciencesProspective StudiesProspective cohort studylcsh:Science610 Medicine &amp; healthTomographyHearing DisordersAged 80 and overNeuronsMultidisciplinaryAlcohol ConsumptionRadiology and ImagingAxial lengthMiddle AgedAxial Length EyeLifestyle factorsNeurologyRegression AnalysisFemaleCellular TypesAnatomyTomography Optical CoherenceResearch ArticleAdultmedicine.medical_specialtyImaging TechniquesNerve fibre layer610 Medicine & healthHomocysteine levelsResearch and Analysis MethodsRetina03 medical and health sciencesSex FactorsOcular SystemDiagnostic MedicineOphthalmologymedicineHumansddc:610Life StyleAgedNutritionbusiness.industryMorphometrylcsh:RBiology and Life SciencesRetinalGlaucomaCell Biologymedicine.diseaseeye diseasesDietOphthalmologychemistryOtorhinolaryngologyCellular Neuroscience030221 ophthalmology & optometryEyeslcsh:Qsense organsbusinessHead030217 neurology & neurosurgeryNeuroscience
researchProduct

Genetic variants associated with human eye size are distinct from those conferring susceptibility to myopia

2021

Purpose: Emmetropization requires coordinated scaling of the major ocular components, corneal curvature and axial length. This coordination is achieved in part through a shared set of genetic variants that regulate eye size. Poorly coordinated scaling of corneal curvature and axial length results in refractive error. We tested the hypothesis that genetic variants regulating eye size in emmetropic eyes are distinct from those conferring susceptibility to refractive error.Methods: A genome-wide association study (GWAS) for corneal curvature in 22,180 adult emmetropic individuals was performed as a proxy for a GWAS for eye size. A polygenic score created using lead GWAS variants was tested for…

MaleRefractive errorLinkage disequilibriumgenetic structuresLOCIEmmetropiaGenome-wide association studyPRSS56AXIAL LENGTHLinkage Disequilibrium0302 clinical medicineCORNEAL CURVATURECorneaMyopiarefractive errorChild0303 health sciencesHERITABILITYMiddle Agedgenetic correlationAxial Length Eyemedicine.anatomical_structureeye sizeGROWTHFemaleAdultmedicine.medical_specialtyUK BiobankAdolescentBiologyRefraction OcularGenetic correlationPolymorphism Single NucleotideOCULAR COMPONENT DIMENSIONS03 medical and health sciencesYoung AdultOphthalmologymedicineGeneticsHumansGenetic Predisposition to Disease3125 Otorhinolaryngology ophthalmologyGENOME-WIDE ASSOCIATIONMETAANALYSIS030304 developmental biologyAgedmedicine.diseaseeye diseasesGenetic marker030221 ophthalmology & optometryHuman eyesense organsGenome-Wide Association StudyInvestigative Ophthalmology & Visual Science
researchProduct

Optical coherence tomography angiography evaluation of peripapillary microvascular changes after rhegmatogenous retinal detachment repair

2021

PURPOSE To evaluate the radial peripapillary capillary plexus (RPCP) vessel density (VD) and the retinal nerve fiber layer (RNFL) thickness in eyes successfully treated with pars plana vitrectomy for primary rhegmatogenous retinal detachment. METHODS In this cross-sectional multicenter clinical study, eyes with a minimum 12-month follow-up were reexamined. The RPCP VD and RNFL thickness in the rhegmatogenous retinal detachment subfields of the affected eye (study group) were compared with the corresponding areas of the healthy fellow eyes (control group). RESULTS Fifty-three eyes were included in the study. A significantly lower RPCP VD and RNFL thickness were observed in those subfields af…

MaleRetinal Ganglion Cellsgenetic structuresComputed Tomography Angiographymedicine.medical_treatmentNerve fiber layerVisual AcuityVitrectomyEyeradial peripapillary capillary plexuschemistry.chemical_compoundNerve FibersVitrectomyTomographyRetinal detachment repairRetinal detachmentGeneral MedicineMiddle AgedAxial Length Eyemedicine.anatomical_structureFemaleTomography Optical CoherencePars planamedicine.medical_specialtyBiometryOptic DiskEndotamponaderetinal detachmentOCT-angiography; Radial peripapillary capillary plexus; Retinal detachment; Retinal nerve fiber layer; Aged; Axial Length Eye; Biometry; Cross-Sectional Studies; Endotamponade; Female; Humans; Male; Middle Aged; Nerve Fibers; Optic Disk; Retinal Detachment; Retinal Ganglion Cells; Retinal Vessels; Retrospective Studies; Visual Acuity; Computed Tomography Angiography; Tomography Optical Coherence; VitrectomyOphthalmologymedicineHumansAxial LengthAgedRetrospective StudiesRetinabusiness.industryradial peripapillary capillary plexus; OCT-angiography; retinal nerve fiber layer; retinal detachmentRetinal Vesselsretinal nerve fiber layerRetinalOptical coherence tomography angiographymedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudieschemistryOptical Coherencesense organsOCT-angiographybusiness
researchProduct