Search results for "BALANCE"
showing 10 items of 1379 documents
Solubilization control by redox-switching of polysoaps
2008
Reversible changes in the self-organization of polysoaps may be induced by controlling their charge numbers via covalently bound redox moieties. This is illustrated with two viologen polysoaps, which in response to an electrochemical stimulus, change their solubility and aggregation in water, leading from homogeneously dissolved and aggregated molecules to collapsed ones and vice verse. Using the electrochemical quartz crystal microbalance (EQCM), it could be shown that the reversibility of this process is better than 95% in 16 cycles.
Documentation and Archiving
2014
In this chapter a historical survey on the development of balances is presented, also in tabular form. The documentation of balance constructions in museums and literature is shown. The development of science museums, technical libraries, and societies which include balances is reviewed, and a list of museums which exhibit balances is given.
Is the NZEB Benchmarking Approach Suitable for Assessing Energy Retrofit Design?
2013
Currently, many effort have been done to enable energy saving issues in building design and many definitions have been introduced for most performing constructions based on energy balance between energy demand and supply. Recently, the Net Zero Energy Building theory has bypassed old Passive House concept but many questions still remain open. Present work aims to estimate how NZEB requirements matching could be affected by the choice of their definition and the choice of weighting factor system, to be count in the energy balance. NZEB concept is mainly referred to new buildings design. Its application to existing buildings is for sure an hard task provided the architecture and physical cons…
Ten years surface-atmosphere water budget from the ISAC micrometeorological base in Salento peninsula and comments on the aquifer balance
2016
Data from a ten years (2003-2013) period of activity of the ISAC-Lecce micrometeorological station have been discussed focusing on the atmosphere-surface exchange. Some suitable indices have been calculated such as the precipitation intensity, the aridity index and the ground water infiltration fraction (ratio of the difference between precipitation and real evapotranspiration and the precipitation). Possible trends of annual averages in the decadal period are considered, trying to take also into account the statistical uncertainty associated to measurement errors and missing data. The results indicate a significant increasing in the precipitation intensity together with an experimental evi…
Artificial Neural Networks to assess energy and environmental performance of buildings: An Italian case study
2019
Abstract Approximately 40% of the European energy consumption and a large proportion of environmental impacts are related to the building sector. However, the selection of adequate and correct designs can provide considerable energy savings and reduce environmental impacts. To achieve this objective, a simultaneous energy and environmental assessment of a building's life cycle is necessary. To date, the resolution of this complex problem is entrusted to numerous software and calculation algorithms that are often complex to use. They involve long diagnosis phases and are characterised by the lack of a common language. Despite the efforts by the scientific community in the building sector, th…
Application of optimized artificial intelligence algorithm to evaluate the heating energy demand of non-residential buildings at European level
2019
Abstract A reliable preliminary forecast of heating energy demand of a building by using a detailed dynamic simulation software typically requires an in-depth knowledge of the thermal balance, several input data and a very skilled user. The authors will describe how to use Artificial Neural Networks to predict the demand for thermal energy linked to the winter climatization of non-residential buildings. To train the neural network it was necessary to develop an accurate energy database that represents the basis of the training of a specific Artificial Neural Networks. Data came from detailed dynamic simulations performed in the TRNSYS environment. The models were built according to the stan…
Differential Leakage Factor in Electrical Machines Equipped with Asymmetrical Multiphase Windings: a General Investigation
2019
This paper presents an investigation in terms of degree of unbalance and leakage factor of electrical machines equipped with multiphase windings. The analysis has been carried out through 4800 combinations between slots/poles/phases/layers, analyzing the variability of the leakage factor for each condition and determining the optimal region for its minimization. The obtained results demonstrate that the leakage factor could be considerably reduced with the adoption of slightly asymmetrical windings, which represent a favorable option during the early design stage of electrical machines.
The barotropic model
2003
Bias correction of dynamically downscaled precipitation to compute soil water deficit for explaining year-to-year variation of tree growth over north…
2017
This paper documents the accuracy of a post-correction method applied to precipitation regionalized by the Weather Research and Forecasting (WRF) Regional Climate Model (RCM) for improving simulated rainfall and feeding impact studies. The WRF simulation covers Burgundy (northeastern France) at a 8-km resolution and over a 20-year long period (1989–2008). Previous results show a strong deficiency of the WRF model for simulating precipitation, especially when convective processes are involved. In order to reduce such biases, a Quantile Mapping (QM) method is applied to WRF-simulated precipitation using the mesoscale atmospheric analyses system SAFRAN («Système d'Analyse Fournissant des Rense…
Estimating energy balance fluxes above a boreal forest from radiometric temperature observations
2009
Abstract The great areal extent of boreal forests confers these ecosystems potential to impact on the global surface-atmosphere energy exchange. A modelling approach, based on a simplified two-source energy balance model, was proposed to estimate energy balance fluxes above boreal forests using thermal infrared measurements. Half-hourly data from the Solar-Induced Fluorescence Experiment, carried out in a Finnish boreal forest, was used to evaluate the performance of the model. Energy balance closure, determined by linear regression, found all fluxes to underestimate available energy by 9% (r2 = 0.94). Significance in the energy balance of the heat storage in the air and in the soil terms w…