Search results for "BAND"
showing 10 items of 2610 documents
Semiconducting half-Heusler and LiGaGe structure type compounds
2009
Compounds with LiAlSi (half-Heusler) and LiGaGe structure types have been investigated by means of band structure calculations. The LiAlSi structure type is known as the half-Heusler structure type, whereas LiGaGe is a closely related hexagonal variant. A remarkable feature of some XYZ half-Heusler compounds with 8 and 18 valence electrons is, that despite being composed of only metallic elements, they are semiconductors. More than 100 semiconducting compounds within these structure types are known. LiGaGe compounds have an additional degree of freedom, namely the degree of puckering of the layers. These compounds can become semiconducting at a certain degree of puckering. Half-metallic beh…
Behaviour of Nb2O5/PPy contacts: From Schottky barriers to p-n junctions
2009
In this work, a study of the photoelectrochemical responses of Nb O /PPy contacts fabricated in both organic 2 5 and aqueous solutions is performed. From the comparison between the experimental data of PPy photodeposited on Nb O in organic and in aqueous solutions, it is evident that the medium used for the photodeposition 2 5 influences the absorption coefficient, the band gap and flat band potential values.
Light induced electropolymerization of poly(3,4-ethylenedioxythiophene) on niobium oxide
2010
Abstract The photoelectrochemical polymerization of poly(3,4-ethylenedioxythiophene), PEDOT, was successfully realized on anodic film grown to 50 V on magnetron sputtered niobium. Photocurrent Spectroscopy was employed to study the optical properties of Nb/Nb 2 O 5 /PEDOT/electrolyte interface in a large range of potential, and to get an estimate of the band gap and flat band potential of both the oxide and the polymer. Scanning Electron Microscopy was used to study the morphology of PEDOT. Both the optical and morphological features of the photoelectrochemically grown polymer were compared with those showed by PEDOT electropolymerized on gold conducting substrate.
Bandosidades nobiliarias en Valencia durante la época foral
1985
La intervención de Felipe II en el ajuste de paces entre los bandos de los Borja y los Centelles
2001
El presente artículo analiza la intervención personal de Felipe II en el ajuste de paces entre los Borja y los Centelles, dos de las familias nobiliarias más importantes de la Valencia del siglo XVI, a raíz del nuevo enfrentamiento surgido entre ellas en 1560. A tal fin, a partir de los fondos custodiados en el Archivo General de Simancas, hemos querido recoger la correspondencia cruzada entre el propio monarca y los principales implicados en los bandos, presentando así una visión del problema complementaria a la ofrecida por la documentación estrictamente oficial. (A)
Advanced imaging of the gastrointestinal tract: research vs. clinical tools?
2009
Diagnostic endoscopy has moved forward considerably in the recent years. Still, three major needs have to be satisfied: endoscopy should be able to detect a lesion, characterize the lesion, and then its nature should be confirmed. These steps should ideally translate into an immediate therapeutic decision.High definition endoscopy has optimized our endoscopic view onto the mucosa and can be combined with digital surface enhancement modalities. Chromoendoscopy still holds a place to detect especially flat lesions in high-risk patients such as ulcerative colitis. Digital chromoendoscopy techniques such as narrow band imaging, i-scan, or Fuji intelligent chromo endoscopy offer new possibilitie…
Raman investigation of single oxidized carbon nanotubes
2001
The oxidation process of single-walled carbon nanotubes via nitric acid treatment was followed by IR-, UV-Vis-NIR, and single bundle Raman spectroscopy. The introduction of functional, oxygen-containing groups is revealed by an additional absorption band at 1725 cm−1, characteristic of carbonyl stretch vibrations. No significant shift of the optical absorption bands could be detected after oxidation. The combination of atomic force microscopy and confocal scanning resonance-enhanced Raman microscopy was used to investigate thin bundles and, eventually, individual nanotubes in detail. These experiments enabled determination of the dependence of the Raman intensity of the G-line (around 1590 …
A New Coupling Solution for G3-PLC Employment in MV Smart Grids
2019
This paper proposes a new coupling solution for transmitting narrowband multicarrier power line communication (PLC) signals over medium voltage (MV) power lines. The proposed system is based on an innovative PLC coupling principle, patented by the authors, which exploits the capacitive divider embedded in voltage detecting systems (VDS) already installed inside the MV switchboard. Thus, no dedicated couplers have to be installed and no switchboard modifications or energy interruptions are needed. This allows a significant cost reduction of MV PLC implementation. A first prototype of the proposed coupling system was presented in previous papers: it had a 15 kHz bandwidth useful to couple sin…
Analysis of Offshore Knuckle Boom Crane - Part Two: Motion Control
2013
In this paper design of electro-hydraulic motion control systems for offshore knuckle boom cranes is discussed. The influence of the control valve bandwidth along with the ramp time for the control signal are investigated both analytically with simplified system models and numerically with an experimentally verified crane model. The results of both types of investigations are related to general design rules for selection of control valves and ramp times and the relevance of these design rules is discussed. Generally, they are useful but may be too conservative for offshore knuckle boom cranes. However, as demonstrated in the paper, the only proper way to determine this is to evaluate the mo…
Accurate tuning of mismatched twin-core fiber filters
1998
We have demonstrated a reproducible and accurate way of tuning the coupling wavelength of a mismatched twin-core filter. This method allows high quality all-fiber filters to be implemented with low loss at any desired wavelength over a range of few hundred nanometers from the same fiber. An ~500-nm tuning range is demonstrated, limited only by the measurement setup and not by the technique itself. Highly accurate control of the filtering wavelength in combination with control of filtering strength by adjustment of the length of the twin-core fibers allows complex filter profiles to be implemented by cascading of several different filters. These filters are also very stable to a change in te…