Search results for "BEAM"

showing 10 items of 2126 documents

Random vibration mitigation of beams via tuned mass dampers with spring inertia effects

2019

The dynamics of beams equipped with tuned mass dampers is of considerable interest in engineering applications. Here, the purpose is to introduce a comprehensive framework to address the stochastic response of the system under stationary and non-stationary loads, considering inertia effects along the spring of every tuned mass damper applied to the beam. For this, the key step is to show that a tuned mass damper with spring inertia effects can be reverted to an equivalent external support, whose reaction force on the beam depends only on the deflection of the attachment point. On this basis, a generalized function approach provides closed analytical expressions for frequency and impulse res…

media_common.quotation_subjectSpring inertia effectStochastic response02 engineering and technologyInertia01 natural sciences0203 mechanical engineeringDeflection (engineering)Control theoryTuned mass damper0103 physical sciences010301 acousticsImpulse responsemedia_commonPhysicsGeneralized functionMechanical EngineeringBeamGeneralized functionCondensed Matter PhysicsTuned mass damper020303 mechanical engineering & transportsReactionMechanics of MaterialsRandom vibrationBeam (structure)
researchProduct

Artefacts in CBCT: a review

2011

Artefacts are common in today's cone beam CT (CBCT). They are induced by discrepancies between the mathematical modelling and the actual physical imaging process. Since artefacts may interfere with the diagnostic process performed on CBCT data sets, every user should be aware of their presence. This article aims to discuss the most prominent artefacts identified in the scientific literature and review the existing knowledge on these artefacts. We also briefly review the basic three-dimensional (3D) reconstruction concept applied by today's CBCT scanners, as all artefacts are more or less directly related to it.

medicine.medical_specialtyCone beam computed tomographyComputer scienceMetal artefactImage processingReviewImaging Three-DimensionalScattering radiationImage Processing Computer-AssistedmedicineHumansScattering RadiationRadiology Nuclear Medicine and imagingMedical physicsComputer visionGeneral DentistryCone beam ctPhantoms Imagingbusiness.industryGeneral MedicineCone-Beam Computed TomographyModels TheoreticalRadiographic Image EnhancementOtorhinolaryngologyArtificial intelligenceArtifactsbusinessAlgorithmsDentomaxillofacial Radiology
researchProduct

Cone beam computed tomography diagnostic imaging of intra-osseous mucoepidermoid carcinoma in the mandible

2017

Intra-osseous mucoepidermoid carcinoma in the mandible is a rarely reported entity, comprising only 2-3% of all mucoepidermoid carcinomas. Unilocular and/or multilocular radiolucency is characteristic of mucoepidermoid carcinoma, but has a radiographic appearance similar to that of odontogenic benign and malignant tumors and thus cannot be accurately diagnosed on plain films. This article describes a case of a 36-year-old man with intra-osseous mucoepidermoid carcinoma in the left mandible. For a detailed analysis, both panoramic radiograph and cone beam computed tomograph were taken. Important clinico-pathological and imaging features, differential diagnosis and review of the literature ar…

medicine.medical_specialtyCone beam computed tomographyOral Medicine and PathologyPanoramic radiographbusiness.industryRadiographyMandibleCase Report030206 dentistry:CIENCIAS MÉDICAS [UNESCO]medicine.disease03 medical and health sciencesstomatognathic diseases0302 clinical medicineMucoepidermoid carcinomaUNESCO::CIENCIAS MÉDICASMedical imagingmedicineRadiologyTomographyDifferential diagnosis030223 otorhinolaryngologybusinessGeneral Dentistry
researchProduct

Impact of cone-beam computed tomography for the identification and management of an oral portal of entry in patients with infective endocarditis. A D…

2021

Background Infective endocarditis (IE) is a rare and life-threatening disease. Cutaneous portal of entry (POE) is predominant for IE, but an oral POE is the second most frequent source. Thus looking for and treating an oral POE in IE patients is of critical importance in order to reduce the risk of IE relapse or recurrence. The objectives of this study were: 1) To reach a consensus on decision-making following the detection of an oral POE on cone-beam computed tomography (CBCT) while they were not identified using the current recommended approach in IE patients (oral examination and orthopantomogram: OPT). 2) To determine whether this consensus differs when regarding the microbiology of IE.…

medicine.medical_specialtyCone beam computed tomographyPanoramic radiographDelphi TechniquediagnosisDelphi methodMEDLINERadiography PanoramicmedicineHumansIn patientDental CareGeneral DentistryUNESCO:CIENCIAS MÉDICASangina bullosa haemorrhagicaResponse rate (survey)oral mucosa blistersEndocarditisbusiness.industryResearchGeneral surgeryCone-Beam Computed Tomographymedicine.diseaseOtorhinolaryngologyRadiological weaponInfective endocarditisSurgeryOral Surgerybusiness
researchProduct

Comparison of the diagnostic efficacy of 2D radiography and cone beam computed tomography in persistent apical periodontal disease: A PRISMA-DTA syst…

2021

Objective The objective of this study was to answer the question: Do conventional radiographs (periapical/panoramic) afford better diagnostic outcomes than cone beam computed tomography (CBCT) as a complement for clinical diagnosis of apical lesions with persistent apical periodontitis or disease after root canal treatment? Study Design Five electronic databases were searched and provided information to enable construction of a table to determine primary diagnostic measures and secondary parameters. The evidence was appraised with the Quality Assessment of Diagnostic Accuracy Studies tool and GRADEpro software. Results Twenty-seven articles (9903 diagnostic images) were included. The pooled…

medicine.medical_specialtyCone beam computed tomographyReceiver operating characteristicbusiness.industryRoot canalRadiographyCone-Beam Computed TomographyPredictive valuePathology and Forensic MedicineTherapeutic goalmedicine.anatomical_structurePeriodontal diseaseROC CurveMeta-analysisMedicineHumansRadiology Nuclear Medicine and imagingDentistry (miscellaneous)SurgeryRadiologyOral SurgerybusinessPeriapical PeriodontitisOral surgery, oral medicine, oral pathology and oral radiology
researchProduct

Technical and surgical aspects of the sphenopalatine ganglion (SPG) microstimulator insertion procedure

2015

Cluster headache (CH) is a debilitating, severe form of headache. A novel non-systemic therapy has been developed that produces therapeutic electrical stimulation to the sphenopalatine ganglion (SPG). A transoral surgical technique for inserting the Pulsante SPG Microstimulator into the pterygopalatine fossa (PPF) is presented herein. Technical aspects include detailed descriptions of the preoperative planning using computed tomography or cone beam computed tomography scans for presurgical digital microstimulator insertion into the patient specific anatomy and intraoperative verification of microstimulator placement. Surgical aspects include techniques to insert the microstimulator into the…

medicine.medical_specialtyCone beam computed tomographymedicine.medical_treatmentPterygopalatine FossaCluster HeadacheElectric Stimulation TherapyRadiography Interventional03 medical and health sciences0302 clinical medicinemedicineHumansPain ManagementInsertion procedure030212 general & internal medicineDental implantNeurostimulationsphenopalatine ganglionPterygopalatine fossaPain Measurementbusiness.industryCluster headachepterygopalatine fossacluster headacheGanglia ParasympatheticPerioperativeEquipment DesignCone-Beam Computed Tomographymedicine.diseaseGanglionSurgerymedicine.anatomical_structureOtorhinolaryngologyneuromodulationSurgeryOral SurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryneurostimulation
researchProduct

Variations in acoustical beam properties of intracoronary Doppler catheters.

1993

The limitations of coronary angiography in assessing the functional significance of coronary obstructions is well known. While the critical variable of coronary blood flow cannot be readily measured, intraluminal Doppler sonography offers useful related functional information on blood flow velocity. In order to fully evaluate Doppler signals it is essential to have exact knowledge of the transducer transmission characteristics and of the ultrasound beam topology. In an experimental set-up, the transmitter-receiver characteristics of five commonly used Doppler catheters were investigated. In comparing the beam characteristics we found inhomogeneities in the lateral beam spread. At a penetrat…

medicine.medical_specialtyCoronary DiseaseSignalsymbols.namesakeCoronary CirculationComputer GraphicsMedicineHumansComputer SimulationAngioplasty Balloon CoronaryUltrasonography Interventionalbusiness.industryUltrasoundModels CardiovascularSignal Processing Computer-AssistedBlood flowEquipment DesignLaser Doppler velocimetryEchocardiography DopplerTransducersymbolsUltrasonic sensorRadiologyCardiology and Cardiovascular MedicinebusinessDoppler effectBeam (structure)Blood Flow VelocityBiomedical engineeringCatheterization and cardiovascular diagnosis
researchProduct

Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility

2017

Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…

medicine.medical_specialtyIon beamComputer scienceNuclear engineeringmedicine.medical_treatmentImaging phantomPelvis030218 nuclear medicine & medical imagingMedical physicist03 medical and health sciences0302 clinical medicinemedicineHumansDosimetryMedical physicsRadiometryPencil-beam scanningIonsPhantoms ImagingRadiation DosimetersUncertaintyGeneral MedicinePencil (optics)Radiation therapy030220 oncology & carcinogenesisSoftwareMedical Physics
researchProduct

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

2008

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calc…

medicine.medical_specialtyMaterials sciencePhotonbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineRadiationComputational physicsElectromagnetic shieldingmedicineMedical physicsRadiation protectionbusinessHalf-value layerBeam (structure)Medical Physics
researchProduct

Broad-beam transmission data for new brachytherapy sources, Tm-170 and Yb-169

2005

The characteristics of the radionuclides (170)Tm and (169)Yb are highly interesting for their use as high dose-rate brachytherapy sources. The introduction of brachytherapy equipment containing these sources will lead to smaller required thicknesses of the materials used in radiation protection barriers compared with the use of conventional sources such as (192)Ir and (137)Cs. The purpose of this study is to determine the required thicknesses of protection material for the design of the protecting walls. Using the Monte Carlo method, transmission data were derived for broad-beam geometries through lead and concrete barriers, from which the first half value layer and tenth value layer are ob…

medicine.medical_specialtyMaterials sciencemedicine.medical_treatmentBrachytherapyBrachytherapyMonte Carlo methodOpticsmedicineHumansRadiology Nuclear Medicine and imagingMedical physicsYtterbiumRadioisotopesRadiationRadiological and Ultrasound Technologybusiness.industryPublic Health Environmental and Occupational HealthRadiotherapy DosageGeneral MedicineBeam transmissionIridium RadioisotopesTransmission (telecommunications)Cesium RadioisotopesThuliumCalibrationDose reductionRadiation protectionbusinessMonte Carlo MethodHalf-value layerRadiation Protection Dosimetry
researchProduct