Search results for "Balloon"
showing 10 items of 238 documents
Variations in acoustical beam properties of intracoronary Doppler catheters.
1993
The limitations of coronary angiography in assessing the functional significance of coronary obstructions is well known. While the critical variable of coronary blood flow cannot be readily measured, intraluminal Doppler sonography offers useful related functional information on blood flow velocity. In order to fully evaluate Doppler signals it is essential to have exact knowledge of the transducer transmission characteristics and of the ultrasound beam topology. In an experimental set-up, the transmitter-receiver characteristics of five commonly used Doppler catheters were investigated. In comparing the beam characteristics we found inhomogeneities in the lateral beam spread. At a penetrat…
Efficacy and safety of endoscopic balloon dilation of symptomatic intestinal Crohn's disease strictures
2011
Abstract Aim To evaluate prospectively the clinical efficacy and safety of endoscopic hydrostatic balloon dilation in a consecutive cohort of symptomatic intestinal Crohn's disease strictures. Methods Between September 2003 and December 2008 we performed endoscopic balloon dilations in 37 Crohn's disease patients with 39 intestinal symptomatic strictures (4 naive and 35 postoperative). Dilations were performed using a Rigiflex through-the-scope balloon. Clinical success rate was claimed if a patient remained asymptomatic and did not require surgery or further endoscopic dilation, following technical success. Actuarial curves of clinical, endoscopic (redilation) and surgical recurrence were …
Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease
2020
Abstract Objectives This study sought to compare the performance of a novel drug-coated balloon (DCB) (Elutax SV, Aachen Resonance, Germany), with an everolimus-eluting stent (EES) (Abbott Vascular...
Drug-coated balloon without stent implantation for chronic total occlusion of coronary arteries: Description of a new strategy with an optical cohere…
2015
Consensus on Treatment of Obstructive Eustachian Tube Dysfunction With Balloon Eustachian Tuboplasty
2020
Abstract Objective There is a great variability in diagnosis of obstructive Eustachian tube dysfunction and its treatment by balloon Eustachian tuboplasty (BET). The aim of this paper was to present a consensus on indications, contraindications, methodology, complications and results after BET. Material & Methods We obtained a consensus on BET, after a systematic review of the literature on BET from 1966 to November 2018, using MESH terms “Eustachian tube and (dilation or dysfunction)”, including a total of 1.943 papers in Spanish, English, German and French. We selected 139 papers with a relevant abstract, including two international consensuses, seven systematic revisions, and two randomi…
Successful tracheal occlusion using ultrathin fetoscopic equipment combined with real-time three-dimensional ultrasound.
2008
<i>Objective:</i> The most common complication of intrauterine tracheal balloon occlusion is the preterm premature rupture of membranes (PPROM) which increases the rate of neonatal morbidity and mortality. Ultrathin fetoscopy may be a method of reducing the risk of PPROM. <i>Materials and Methods:</i> The operation was performed at the 27th week of gestation after sedation and relaxation of a fetus with bilateral congenital diaphragmatic hernia and with the liver lifted upwards into the thorax. An ultrathin sheath with a 1.2-mm fetoscope was used under real-time 3-D ultrasound guidance. The patient delivered in the 38th week of gestation and did not display PPROM aft…
Chronic thromboembolic pulmonary hypertension from the perspective of patients with pulmonary embolism
2018
Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare but feared long-term complication of acute pulmonary embolism (PE), although CTEPH may occur in patients with no history of symptomatic venous thromboembolism. It represents the most severe presentation of the so-called 'post-PE syndrome', a phenomenon of permanent functional limitations after PE caused by deconditioning after PE or ventilatory or circulatory impairment as a result of unresolved pulmonary artery thrombi. Because the post-PE syndrome may occur in up to 50% of PE survivors, and CTEPH tends to have an insidious and non-specific clinical presentation, CTEPH is often not diagnosed or diagnosed after a very long dela…
Phrenic nerve displacement by intrapericardial balloon inflation during epicardial ablation of ventricular tachycardia: Four case reports
2020
BACKGROUND Phrenic nerve (PN) injury is one of the recognized possible complications following epicardial ablation of ventricular tachycardia (VT). High-output pacing is a widely used maneuver to establish a relationship between the PN and the ablation catheter tip. An absence of PN capture is usually considered an indication that it is safe to ablate, and that successful ablation may be performed at adjacent sites. However, PN capture may impact the procedural outcome. Only a few cases have been reported in the literature that avoid PN injury by using different techniques. CASE SUMMARY Three patients with a previous history of myocarditis and one patient with ischemic cardiomyopathy underw…
Vertebrobasilar junction giant aneurysm: Lessons learned from a neurosurgical audit and anatomical investigation.
2015
The treatment of vascular lesions of the vertebrobasilar junction (VBJ) remains a challenging task in the neurosurgical practice and the gold standard therapy is still under debate. In this article, the authors report a detailed postmortem study of a VBJ giant aneurysm (GA) previously endovascularly treated. Although the decision-making process for the vast majority of neurosurgical treatment can nowadays be accurately carried out during the preoperative planning (i.e., with the aid of neuroimaging fusion protocols, neuronavigation platforms, etc.) meant to maximize the anatomical understanding of the lesions and minimize possible intraprocedural challenges, this postmortem study represents…
Coronary Spasm in Patients Treated by Percutaneous Transluminal Coronary Angioplasty
1986
The appearance of coronary spasm during PTCA was analyzed in 140 consecutive patients with stable and unstable angina. Coronary spasm was found in 27 patients (19%) and was more common in unstable than in stable angina pectoris (22 versus 5 patients). While coronary spasm could be seen in the first coronary angiogram in 5/27 patients, it developed during the diagnostic procedure in 6/27 patients. In 16/27 patients coronary spasm was induced by the balloon or the guide wire itself.