Search results for "Balloon"
showing 10 items of 238 documents
Total occlusion of aortic arch in a 62-year-old man presenting with acute myocardial infarction
2011
Not available
Transcervical approach for carotid artery stenting with transitory reversal flow: Case report
2021
Introduction Carotid artery stenting (CAS) has been indicated as an alternative to carotid endarterectomy in high risk patients. Sometimes, an aortic arch can be anatomically unfavourable for CAS. Herein we report our experience in a case of CAS with transcervical approach. Presentation of case A 77-year-old male was referred to our hospital for severe subtotal occlusion of the left internal carotid artery. He had a past medical history of radiation to the head and neck for laryngeal cancer. Previous CT-angiography had shown a type III aortic with bovine arch. CAS via transcervical approach was performed with transitory reversal flow during the placement of RX Spider Filter 6 Fr (Medtronic,…
Echocardiographic and angiographic evaluation of left ventricular function during percutaneous transluminal aortic valvuloplasty.
1992
Transesophageal echocardiography was used to study the effect of the balloon inflation on left ventricular function in 20 patients with critical aortic stenosis undergoing balloon valvuloplasty. Balloon inflation caused an increase of end-diastolic (15% to 34%) and end-systolic (57% to 72%) left ventricular volume. Left ventricular wall stress increased from 30 +/- 10 x 10(3) dyn/cm2 at diastole and 121 +/- 40 x 10(3) dyn/cm2 at systole to 44 +/- 11 x 10(3) dyn/cm2 and 191 +/- 55 x 10(3) dyn/cm2, respectively, when the balloon was inflated (P less than 0.05). Turbulent regurgitant jet across the mitral valve increased from 15 +/- 2% to 25 +/- 3% during balloon inflation (P less than 0.01). …
Modified hemi-Fontan procedure on the beating heart
1998
the heart by infusing the cardioplegic solution under aortic occlusion by means of the balloon throughout the procedure. Even though the balloon catheter passes through the aortic valve, significant aortic valve insufficiency is not likely to occur because of the small caliber of the balloon catheter. We believe that the clinical application of this double-lumen aortic occlusion catheter will protect the myocardium in patients with a thoracoabdominal aortic aneurysm or distal descending aortic aneurysm who undergo the operation through the left thoracotomy with DHCA.
Assessment of left ventricular function during aortic balloon valvuloplasty by transesophageal echocardiography
1989
Several reports have documented the feasability and utility of balloon aortic valvuloplasty as a palliative treatment for high-surgical-risk patients with critical aortic valve stenosis (1–3).
We are Still Learning from Death: After CPR, Balloon Expanding Valve (Intuity Aortic Valve) Revealed to be in Position
2021
Patients with high predicated risk undergo TAVI as an alternative treatment to surgical valve replacement...
High-frequency rotational ablation following failed percutaneous transluminal coronary angioplasty.
1994
Percutaneous transluminal coronary angioplasty (PTCA) failed in 29 of 1,150 patients (2.5%) after successful passage of the guide wire. The reasons for failure were inability to pass the lesion with a balloon in 28 patients and inability to dilate the lesion in 1 patient. In these patients (15 stenoses and 14 chronic occlusions) rotational ablation was performed. We were able to pass the burr through the lesion in all of them, resulting in a reduction of diameter stenosis from 87 +/- 15 to 51 +/- 18%. Rotational ablation alone was initially successful (stenoses reduction > 20% and residual stenoses < 50%) in 15 of 29 (52%) patients. Additional PTCA was performed in 21 of 29 (72%) patients, …
Imaging in the catheterization laboratory
1993
Recent work confirms that visual assessment of the effect of widely employed coronary interventions is highly inaccurate. Rapid and reliable on-line angiographic quantitation is a useful advance, but problems in the application of the technique are encountered in a substantial number of cases. New algorithms have been devised to provide a comprehensive assessment of the geometry and likely functional significance of lesions as well as an objective evaluation of lesion morphology, and recent work has provided the framework for the quantitation of diffuse disease. Studies with intravascular ultrasound confirm the inadequate sensitivity of angiography in demonstrating mild to moderate atheroma…
Inter-comparison of stratospheric O&lt;sub&gt;3&lt;/sub&gt; and NO&lt;sub&gt;2&lt;/sub&gt; abundances retrieved from …
2006
Abstract. Stratospheric O3 and NO2 abundances measured by different remote sensing instruments are inter-compared: (1) Line-of-sight absorptions and vertical profiles inferred from solar spectra in the ultra-violet (UV), visible and infrared (IR) wavelength ranges measured by the LPMA/DOAS (Limb Profile Monitor of the Atmosphere/Differential Optical Absorption Spectroscopy) balloon payload during balloon ascent/descent and solar occultation are examined with respect to internal consistency. (2) The balloon borne stratospheric profiles of O3 and NO2 are compared to collocated space-borne skylight limb observations of the Envisat/SCIAMACHY satellite instrument. The trace gas profiles are retr…
Transmediterranean flights, in the edge of two centuries
2004
Abstract Transmediterranean flights take place at 40 km altitude and approximately 38°N latitude. Sixty six successful trans-mediterranean crossings have been performed in the period 1977–2002. A summary of system requirements, that would assure state-of-the-art stratospheric balloon flights is presented. Details of the 2002 campaign, along with a historical review of the flights corresponding to the Nineties, 2000 and 2001, are presented.