Search results for "Beam"
showing 10 items of 2126 documents
Direct Measurement of Focusing Fields in Active Plasma Lenses
2018
Physical review accelerators and beams 21(12), 122801 (2018). doi:10.1103/PhysRevAccelBeams.21.122801
Simulations and measurements of beam loss patterns at the CERN Large Hadron Collider
2014
The CERN Large Hadron Collider (LHC) is designed to collide proton beams of unprecedented energy, in order to extend the frontiers of high-energy particle physics. During the first very successful running period in 2010-2013, the LHC was routinely storing protons at 3.5-4 TeV with a total beam energy of up to 146 MJ, and even higher stored energies are foreseen in the future. This puts extraordinary demands on the control of beam losses. An uncontrolled loss of even a tiny fraction of the beam could cause a superconducting magnet to undergo a transition into a normal-conducting state, or in the worst case cause material damage. Hence a multistage collimation system has been installed in ord…
International workshop on next generation gamma-ray source
2022
Journal of physics / G 49(1), 010502 (2022). doi:10.1088/1361-6471/ac2827
Design of a 10 GHz minimum-B quadrupole permanent magnet electron cyclotron resonance ion source
2020
This paper presents a simulation study of a permanent magnet electron cyclotron resonance ion source (ECRIS) with a minimum-B quadrupole magnetic field topology. The magnetic field is made to conform to conventional ECRIS with $B_\textrm{min}/B_\textrm{ECR}$ of 0.67 and a last closed magnetic isosurface of 1.86$B_\textrm{ECR}$ at 10 GHz. The distribution of magnetic field gradients parallel to the field, affecting the electron heating efficiency, cover a range from 0 to 13 T/m, being similar to conventional ECRIS. Therefore it is expected that the novel ion source produces warm electrons and high charge state ions in significant number. Single electron tracking simulations are used to estim…
Channeling experiments at planar diamond and silicon single crystals with electrons from the Mainz Microtron MAMI
2020
Line structures were observed for (110) planar channeling of electrons in a diamond single crystal even at a beam energy of 180 MeV . This observation motivated us to initiate dechanneling length measurements as function of the beam energy since the occupation of quantum states in the channeling potential is expected to enhance the dechanneling length. High energy loss signals, generated as a result of emission of a bremsstrahlung photon with about half the beam energy at channeling of 450 and 855 MeV electrons, were measured as function of the crystal thickness. The analysis required additional assumptions which were extracted from the numerical solution of the Fokker-Planck equation. Prel…
Characterization and Tuning of Ultra High Gradient Permanent Magnet Quadrupoles
2009
The application of quadrupole devices with high field gradients and small apertures requires precise control over higher order multipole field components. We present a new scheme for performance control and tuning, which allows the illumination of most of the quadrupole device aperture because of the reduction of higher order field components. Consequently, the size of the aperture can be minimized to match the beam size achieving field gradients of up to $500\text{ }\text{ }\mathrm{T}\text{ }{\mathrm{m}}^{\ensuremath{-}1}$ at good imaging quality. The characterization method based on a Hall probe measurement and a Fourier analysis was confirmed using the high quality electron beam at the M…
Modeling of the Achilles Subtendons and Their Interactions in a Framework of the Absolute Nodal Coordinate Formulation
2022
Experimental results have revealed the sophisticated Achilles tendon (AT) structure, including its material properties and complex geometry. The latter incorporates a twisted design and composite construction consisting of three subtendons. Each of them has a nonstandard cross-section. All these factors make the AT deformation analysis computationally demanding. Generally, 3D finite solid elements are used to develop models for AT because they can discretize almost any shape, providing reliable results. However, they also require dense discretization in all three dimensions, leading to a high computational cost. One way to reduce degrees of freedom is the utilization of finite beam elements…
Calculations of high-power production target and beamdump for the GSI future Super-FRS for a fast extraction scheme at the FAIR Facility
2005
A superconducting fragment separator (Super-FRS) is being designed for the production and separation of radioactive isotopes at the future FAIR (Facility for Antiprotons and Ion Research) facility at Darmstadt. This paper discusses various aspects and requirements for the high-power production target that will be used in the Super-FRS experiments. The production target must survive over an extended period of time as it will be used during the course of many experiments. The specific power deposited by the high intensity beam that will be generated at the future FAIR facility will be high enough to destroy the target in most of the cases as a result of a single shot from the new heavy ion sy…
Complex power distribution analysis in plates covered with passive constrained layer damping patches
2012
International audience; The vibration of a plate partially covered with a passive constrained layer damping (PCLD) patch is studied from an energetic point of view. The damped plate is excited by an acoustic plane wave. The study is done with a numerical two-dimensional multilayer plate model. Results of the present model are compared to those obtained with three-dimensional finite element models. It is shown that the present model gives accurate results, even for the layer's inner behavior. It is less expansive in terms of computational cost; hence, it can simulate efficiently the structure for higher frequencies. Mathematical formulas for complex mechanical power are presented, and the li…
Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study u…
2015
Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pr…