Search results for "Beam"

showing 10 items of 2126 documents

Direct Measurement of Focusing Fields in Active Plasma Lenses

2018

Physical review accelerators and beams 21(12), 122801 (2018). doi:10.1103/PhysRevAccelBeams.21.122801

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhysics and Astronomy (miscellaneous)Field (physics)FOS: Physical sciences01 natural sciences530law.inventionOpticslaw0103 physical sciencesddc:530Thermal emittancelcsh:Nuclear and particle physics. Atomic energy. Radioactivity010306 general physicsphysics.acc-phPhysics010308 nuclear & particles physicsbusiness.industrySurfaces and InterfacesPlasmaNuclear & Particles PhysicsLens (optics)Physics::Space PhysicsPhysical SciencesCathode raylcsh:QC770-798Physics::Accelerator PhysicsPhysics - Accelerator PhysicsBeam emittancebusinessCharged particle beamBeam (structure)
researchProduct

Simulations and measurements of beam loss patterns at the CERN Large Hadron Collider

2014

The CERN Large Hadron Collider (LHC) is designed to collide proton beams of unprecedented energy, in order to extend the frontiers of high-energy particle physics. During the first very successful running period in 2010-2013, the LHC was routinely storing protons at 3.5-4 TeV with a total beam energy of up to 146 MJ, and even higher stored energies are foreseen in the future. This puts extraordinary demands on the control of beam losses. An uncontrolled loss of even a tiny fraction of the beam could cause a superconducting magnet to undergo a transition into a normal-conducting state, or in the worst case cause material damage. Hence a multistage collimation system has been installed in ord…

Accelerator Physics (physics.acc-ph)Nuclear and High Energy PhysicsPhysics and Astronomy (miscellaneous)Monte Carlo methodFOS: Physical sciencesSuperconducting magnetTracking (particle physics)law.inventionNuclear physicslawlcsh:Nuclear and particle physics. Atomic energy. RadioactivityNuclear Experiment (nucl-ex)Large Hadron Collider (France and Switzerland)Nuclear ExperimentPhysicsLarge Hadron ColliderColliders (Nuclear physics)Particle acceleratorCollimatorSurfaces and InterfacesAccelerators and Storage RingsOrders of magnitude (time)lcsh:QC770-798Physics::Accelerator PhysicsPhysics - Accelerator PhysicsBeam (structure)
researchProduct

International workshop on next generation gamma-ray source

2022

Journal of physics / G 49(1), 010502 (2022). doi:10.1088/1361-6471/ac2827

Accelerator Physics (physics.acc-ph)Nuclear and High Energy Physics[PHYS.NUCL]Physics [physics]/Nuclear Theory [nucl-th]Nuclear Theorynucleon: structurepi: photoproduction[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]conference summarynuclear astrophysicsFOS: Physical scienceslow-energy QCD[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]530bremsstrahlung01 natural scienceselectron: acceleratorNuclear Theory (nucl-th)parity: violationnuclear physicsquantum chromodynamics0103 physical sciencesAgency (sociology)ddc:530gamma-rayApplied researchNuclear Experiment (nucl-ex)010306 general physicsphoton: beamNuclear Experimentactivity reportenergy: lowPhysicsastrophysics010308 nuclear & particles physicsInformation sharinglaserhadronic parity violationgamma raynuclear structureSystems engineeringPhysics - Accelerator PhysicsCompton scatteringJournal of Physics G: Nuclear and Particle Physics
researchProduct

Design of a 10 GHz minimum-B quadrupole permanent magnet electron cyclotron resonance ion source

2020

This paper presents a simulation study of a permanent magnet electron cyclotron resonance ion source (ECRIS) with a minimum-B quadrupole magnetic field topology. The magnetic field is made to conform to conventional ECRIS with $B_\textrm{min}/B_\textrm{ECR}$ of 0.67 and a last closed magnetic isosurface of 1.86$B_\textrm{ECR}$ at 10 GHz. The distribution of magnetic field gradients parallel to the field, affecting the electron heating efficiency, cover a range from 0 to 13 T/m, being similar to conventional ECRIS. Therefore it is expected that the novel ion source produces warm electrons and high charge state ions in significant number. Single electron tracking simulations are used to estim…

Accelerator Physics (physics.acc-ph)PhysicsIon beam analysis010308 nuclear & particles physicsFOS: Physical sciencesElectron01 natural sciences7. Clean energyIon sourceElectron cyclotron resonance030218 nuclear medicine & medical imagingIon03 medical and health sciences0302 clinical medicineBeamlinePhysics::Plasma PhysicsMagnet0103 physical sciencesQuadrupolePhysics::Accelerator PhysicsPhysics - Accelerator PhysicsAtomic physicsInstrumentationMathematical PhysicsJournal of Instrumentation
researchProduct

Channeling experiments at planar diamond and silicon single crystals with electrons from the Mainz Microtron MAMI

2020

Line structures were observed for (110) planar channeling of electrons in a diamond single crystal even at a beam energy of 180 MeV . This observation motivated us to initiate dechanneling length measurements as function of the beam energy since the occupation of quantum states in the channeling potential is expected to enhance the dechanneling length. High energy loss signals, generated as a result of emission of a bremsstrahlung photon with about half the beam energy at channeling of 450 and 855 MeV electrons, were measured as function of the crystal thickness. The analysis required additional assumptions which were extracted from the numerical solution of the Fokker-Planck equation. Prel…

Accelerator Physics (physics.acc-ph)PhysicsSilicon010308 nuclear & particles physicsFOS: Physical sciencesDiamondchemistry.chemical_elementElectronengineering.material01 natural sciencesCrystalLength measurementchemistry0103 physical sciencesengineeringPhysics::Accelerator PhysicsPhysics - Accelerator PhysicsAtomic physics010306 general physicsInstrumentationMicrotronSingle crystalMathematical PhysicsBeam (structure)Journal of Instrumentation
researchProduct

Characterization and Tuning of Ultra High Gradient Permanent Magnet Quadrupoles

2009

The application of quadrupole devices with high field gradients and small apertures requires precise control over higher order multipole field components. We present a new scheme for performance control and tuning, which allows the illumination of most of the quadrupole device aperture because of the reduction of higher order field components. Consequently, the size of the aperture can be minimized to match the beam size achieving field gradients of up to $500\text{ }\text{ }\mathrm{T}\text{ }{\mathrm{m}}^{\ensuremath{-}1}$ at good imaging quality. The characterization method based on a Hall probe measurement and a Fourier analysis was confirmed using the high quality electron beam at the M…

Accelerator Physics (physics.acc-ph)electron beamNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorscompactmagneticlensPhysics and Astronomy (miscellaneous)Field (physics)AperturemultipoleFOS: Physical sciencespermanenthalbachx-felNuclear magnetic resonancetuningquadrupolelcsh:Nuclear and particle physics. Atomic energy. RadioactivityQuadrupole magnetMicrotronPhysicsOrder (ring theory)Surfaces and InterfacesInstrumentation and Detectors (physics.ins-det)beam focusingComputational physicsMagnetQuadrupolelcsh:QC770-798Physics::Accelerator PhysicsPhysics - Accelerator PhysicsMultipole expansion
researchProduct

Modeling of the Achilles Subtendons and Their Interactions in a Framework of the Absolute Nodal Coordinate Formulation

2022

Experimental results have revealed the sophisticated Achilles tendon (AT) structure, including its material properties and complex geometry. The latter incorporates a twisted design and composite construction consisting of three subtendons. Each of them has a nonstandard cross-section. All these factors make the AT deformation analysis computationally demanding. Generally, 3D finite solid elements are used to develop models for AT because they can discretize almost any shape, providing reliable results. However, they also require dense discretization in all three dimensions, leading to a high computational cost. One way to reduce degrees of freedom is the utilization of finite beam elements…

Achilles tendonbeam-to-beam contactarbitrary cross-sectionANCFelasticitykantajännebiomekaniikkamatemaattiset mallitbiomechanicskimmoisuus
researchProduct

Calculations of high-power production target and beamdump for the GSI future Super-FRS for a fast extraction scheme at the FAIR Facility

2005

A superconducting fragment separator (Super-FRS) is being designed for the production and separation of radioactive isotopes at the future FAIR (Facility for Antiprotons and Ion Research) facility at Darmstadt. This paper discusses various aspects and requirements for the high-power production target that will be used in the Super-FRS experiments. The production target must survive over an extended period of time as it will be used during the course of many experiments. The specific power deposited by the high intensity beam that will be generated at the future FAIR facility will be high enough to destroy the target in most of the cases as a result of a single shot from the new heavy ion sy…

Acoustics and UltrasonicsChemistryLiquid jetNuclear engineeringSeparator (oil production)Condensed Matter PhysicsThermal conductionSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsIonNuclear physicsAntiprotonIrradiationBeam energyPower densityJournal of Physics D: Applied Physics
researchProduct

Complex power distribution analysis in plates covered with passive constrained layer damping patches

2012

International audience; The vibration of a plate partially covered with a passive constrained layer damping (PCLD) patch is studied from an energetic point of view. The damped plate is excited by an acoustic plane wave. The study is done with a numerical two-dimensional multilayer plate model. Results of the present model are compared to those obtained with three-dimensional finite element models. It is shown that the present model gives accurate results, even for the layer's inner behavior. It is less expansive in terms of computational cost; hence, it can simulate efficiently the structure for higher frequencies. Mathematical formulas for complex mechanical power are presented, and the li…

Acoustics and UltrasonicsMODELSPlane waveENERGY-FLOW02 engineering and technologyNOISEStress (mechanics)0203 mechanical engineeringDEFORMATIONSYSTEMSHIGH-ORDER THEORYMechanical energyMINDLIN PLATE[ PHYS.MECA.ACOU ] Physics [physics]/Mechanics [physics]/Acoustics [physics.class-ph]Mathematics[SPI.ACOU]Engineering Sciences [physics]/Acoustics [physics.class-ph][PHYS.MECA.VIBR]Physics [physics]/Mechanics [physics]/Vibrations [physics.class-ph]SHEAR CORRECTION FACTORS[ SPI.ACOU ] Engineering Sciences [physics]/Acoustics [physics.class-ph]Mechanical EngineeringLAMINATED PLATES[SPI.MECA.VIBR]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Vibrations [physics.class-ph]Constrained-layer dampingMechanicsBEAMS021001 nanoscience & nanotechnologyCondensed Matter PhysicsFinite element method[ SPI.MECA.VIBR ] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Vibrations [physics.class-ph][PHYS.MECA.ACOU]Physics [physics]/Mechanics [physics]/Acoustics [physics.class-ph]Power (physics)Vibration020303 mechanical engineering & transportsClassical mechanics[ PHYS.MECA.VIBR ] Physics [physics]/Mechanics [physics]/Vibrations [physics.class-ph]Mechanics of MaterialsDissipative system0210 nano-technology
researchProduct

Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study u…

2015

Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pr…

AdultCalcium PhosphatesMaleCone beam computed tomographySinus Floor Augmentationmedicine.medical_specialtyMaterials scienceMaxillary sinusRadiographySinus Floor AugmentationSinus floor elevation03 medical and health sciencesImaging Three-Dimensional0302 clinical medicinemedicineHumansProspective Studies030212 general & internal medicineAgedβ tricalcium phosphatebusiness.industry3d image processingMembranes Artificial030206 dentistryCone-Beam Computed TomographyMiddle AgedSurgeryDurapatiteTreatment Outcomemedicine.anatomical_structureVolume (thermodynamics)Bone SubstitutesRadiographic Image Interpretation Computer-AssistedFemaleCollagenOral SurgerybusinessBiomedical engineeringClinical Oral Implants Research
researchProduct