Search results for "Beni culturali"
showing 10 items of 1017 documents
Room-temperature performance of 3 mm-thick cadmium-zinc-telluride pixel detectors with sub-millimetre pixelization.
2020
Cadmium–zinc–telluride (CZT) pixel detectors represent a consolidated choice for the development of room-temperature spectroscopic X-ray imagers, finding important applications in medical imaging, often as detection modules of a variety of new SPECT and CT systems. Detectors with 3–5 mm thicknesses are able to efficiently detect X-rays up to 140 keV giving reasonable room-temperature energy resolution. In this work, the room-temperature performance of 3 mm-thick CZT pixel detectors, recently developed at IMEM/CNR of Parma (Italy), is presented. Sub-millimetre detector arrays with pixel pitch less than 500 µm were fabricated. The detectors are characterized by good room-temperature performan…
Overview of the JET results with the ITER-like wall
2013
Following the completion in May 2011 of the shutdown for the installation of the beryllium wall and the tungsten divertor, the first set of JET campaigns have addressed the investigation of the retention properties and the development of operational scenarios with the new plasma-facing materials. The large reduction in the carbon content (more than a factor ten) led to a much lower Zeff (1.2-1.4) during L- and H-mode plasmas, and radiation during the burn-through phase of the plasma initiation with the consequence that breakdown failures are almost absent. Gas balance experiments have shown that the fuel retention rate with the new wall is substantially reduced with respect to the C wall. T…
ESR response of watch glasses to neutron irradiation
2012
Abstract In this paper we report the results of the electron spin resonance (ESR) study of the radiation-induced signal of watch glasses exposed to neutrons. This work extends the series of analyses of the response of watch glasses to various radiation beams which our research group is carrying out for possible applications in retrospective dosimetry. We have considered fluences up to about 3 × 1011 cm−2. We evaluated the signal fading and we found that in the first hours after exposure the signal rapidly decreases. After about 1000 h, it decreases much more slowly. The signal was reduced by about 25% in about 5 months. The radiation induced signal is found to be linearly dependent on neutr…
Room-Temperature X-ray response of cadmium-zinc-Telluride pixel detectors grown by the vertical Bridgman technique
2020
In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation o…
Comparison of large-angle production of charged pions with incident protons on cylindrical long and short targets
2009
The HARP Collaboration has presented measurements of the double-differential pi(+/-) production cross section in the range of momentum 100 MeV/c <= p <= 800 MeV/c and angle 0.35 rad <=theta <= 2.15 rad with proton beams hitting thin nuclear targets. In many applications the extrapolation to long targets is necessary. In this article the analysis of data taken with long (one interaction length) solid cylindrical targets made of carbon, tantalum, and lead is presented. The data were taken with the large-acceptance HARP detector in the T9 beam line of the CERN proton synchrotron. The secondary pions were produced by beams of protons with momenta of 5, 8, and 12GeV/c. The tracking and identific…
Development of new CdZnTe detectors for room-temperature high-flux radiation measurements
2017
Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room-temperature X-ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling-heater-method (THM)-grown CZT detectors, recently developed at IMEM-CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm−2 at 1000 V cm−1), a…
Forward production of charged pions with incident protons on nuclear targets at the CERN Proton Synchrotron
2009
et al.
ESR dosimeter material properties of phenols compound exposed to radiotherapeutic electron beams
2017
Abstract There is a need for a sensitive dosimeter using Electron Spin Resonance spectroscopy for use in medical applications, since non-destructive read-out and dose archival could be achieved with this method. This work reports a systematic ESR investigation of IRGANOX ® 1076 exposed to clinical electron beams produced by a LINAC used for radiation therapy treatments. Recently, dosimetric features of this material were investigated for irradiation with 6 0Co γ -photons and neutrons in both pellet and film shape and have been found promising thanks to their high efficiency of radiation-matter energy transfer and radical stability at room temperature. Here the analysis of the dosimetric fea…
ESR response of phenol compounds for dosimetry of gamma photon beams
2014
Abstract In the present paper we investigate the features of IRGANOX® 1076 phenols as a material for electron spin resonance (ESR) dosimetry. We experimentally analyzed the ESR response of pellets of IRGANOX® 1076 phenols irradiated with 60Co photons. The best experimental parameters (modulation amplitude and microwave power) for dosimetric applications have been obtained. The dependence of ESR signal as function of γ dose is found to be linear in the dose range studied (12–60 Gy) and the lowest measurable dose is found to be of the order of 1 Gy. The signal after irradiation is very stable in the first thirty days. From the point of view of the tissue equivalence, these materials have mass…
ESR response of watch glasses to proton beams
2010
In this paper we have analyzed the electron spin resonance (ESR) signal of watch glasses irradiated with %60 MeV proton beams in the dose range between 1 and 105 Gy. The composition of samples expressed in oxides weight percentages has been obtained carrying out X-ray fluorescence spectrometry (XRF) mea- surements. The ESR signal has been studied in terms of its dependence on microwave power and modulation field in order to choose the optimal recording parameters. The dependence of the radioinduced signal on the exposure dose has been investigated. A numerical procedure aimed at improving the sensitivity in the low dose range has been developed.