Search results for "Beni culturali"

showing 10 items of 1017 documents

Room-temperature performance of 3 mm-thick cadmium-zinc-telluride pixel detectors with sub-millimetre pixelization.

2020

Cadmium–zinc–telluride (CZT) pixel detectors represent a consolidated choice for the development of room-temperature spectroscopic X-ray imagers, finding important applications in medical imaging, often as detection modules of a variety of new SPECT and CT systems. Detectors with 3–5 mm thicknesses are able to efficiently detect X-rays up to 140 keV giving reasonable room-temperature energy resolution. In this work, the room-temperature performance of 3 mm-thick CZT pixel detectors, recently developed at IMEM/CNR of Parma (Italy), is presented. Sub-millimetre detector arrays with pixel pitch less than 500 µm were fabricated. The detectors are characterized by good room-temperature performan…

Nuclear and High Energy PhysicsMaterials sciencePhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical Phenomena02 engineering and technology01 natural sciencesDot pitchCollimated lightlaw.inventionCharge sharingchemistry.chemical_compoundOpticslaw0103 physical sciencesInstrumentation010302 applied physicsX-ray and gamma ray detectors; CdZnTe pixel detectors; charge sharing; charge losses; charge-sharing correction; spectroscopic X-ray imagingRadiationPixelbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorCdZnTe pixel detectors charge losses charge sharing charge-sharing correction spectroscopic X-ray imaging X-ray and gamma ray detectors021001 nanoscience & nanotechnologySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)SynchrotronCadmium zinc telluridechemistry0210 nano-technologyPixelizationbusinessJournal of synchrotron radiation
researchProduct

Overview of the JET results with the ITER-like wall

2013

Following the completion in May 2011 of the shutdown for the installation of the beryllium wall and the tungsten divertor, the first set of JET campaigns have addressed the investigation of the retention properties and the development of operational scenarios with the new plasma-facing materials. The large reduction in the carbon content (more than a factor ten) led to a much lower Zeff (1.2-1.4) during L- and H-mode plasmas, and radiation during the burn-through phase of the plasma initiation with the consequence that breakdown failures are almost absent. Gas balance experiments have shown that the fuel retention rate with the new wall is substantially reduced with respect to the C wall. T…

Nuclear and High Energy PhysicsMaterials scienceREGIMENuclear engineeringchemistry.chemical_element-Condensed Matter PhysicEffective radiated powerTungstenNuclear and High Energy Physics; Condensed Matter PhysicsPedestalPLASMA-FACING COMPONENTSTOKAMAK PLASMASJet (fluid)TUNGSTENDivertorperfomancePlasmaPERFORMANCECondensed Matter PhysicsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryBeta (plasma physics)DIVERTORBerylliumAtomic physics
researchProduct

ESR response of watch glasses to neutron irradiation

2012

Abstract In this paper we report the results of the electron spin resonance (ESR) study of the radiation-induced signal of watch glasses exposed to neutrons. This work extends the series of analyses of the response of watch glasses to various radiation beams which our research group is carrying out for possible applications in retrospective dosimetry. We have considered fluences up to about 3 × 1011 cm−2. We evaluated the signal fading and we found that in the first hours after exposure the signal rapidly decreases. After about 1000 h, it decreases much more slowly. The signal was reduced by about 25% in about 5 months. The radiation induced signal is found to be linearly dependent on neutr…

Nuclear and High Energy PhysicsMaterials scienceSettore ING-IND/20 - Misure E Strumentazione NucleariEPR Accidental dosimetry Watch glasses NeutronsRadiationSignalFluencehumanitiesSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)law.inventionNuclear magnetic resonancelawNeutron fluxDosimetryNeutronAtomic physicsNeutron irradiationElectron paramagnetic resonanceInstrumentation
researchProduct

Room-Temperature X-ray response of cadmium-zinc-Telluride pixel detectors grown by the vertical Bridgman technique

2020

In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation o…

Nuclear and High Energy PhysicsPhotonMaterials scienceCdZnTe pixel detectorDot pitchCollimated lightCharge sharinglaw.inventionspectroscopic X-ray imagingchemistry.chemical_compoundlawcharge losseInstrumentationRadiationcharge sharingbusiness.industrySettore FIS/01 - Fisica SperimentaleX-raySynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc tellurideFull width at half maximumCdZnTe pixel detectors; charge losses; charge sharing; spectroscopic X-ray imaging; vertical Bridgman technique; X-ray and gamma-ray detectorsX-ray and gamma-ray detectorschemistryOptoelectronicsvertical Bridgman techniquebusinessX-ray and gamma-ray detector
researchProduct

Comparison of large-angle production of charged pions with incident protons on cylindrical long and short targets

2009

The HARP Collaboration has presented measurements of the double-differential pi(+/-) production cross section in the range of momentum 100 MeV/c <= p <= 800 MeV/c and angle 0.35 rad <=theta <= 2.15 rad with proton beams hitting thin nuclear targets. In many applications the extrapolation to long targets is necessary. In this article the analysis of data taken with long (one interaction length) solid cylindrical targets made of carbon, tantalum, and lead is presented. The data were taken with the large-acceptance HARP detector in the T9 beam line of the CERN proton synchrotron. The secondary pions were produced by beams of protons with momenta of 5, 8, and 12GeV/c. The tracking and identific…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsNuclear TheoryFOS: Physical sciencesddc:500.27. Clean energy01 natural sciencesBildungHigh Energy Physics - ExperimentNuclear physicsHigh Energy Physics - Experiment (hep-ex)Basic research0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]010306 general physicsNuclear ExperimentPhysics010308 nuclear & particles physicsFísicaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Calculation methodsResearch councilPhysics::Accelerator PhysicsAngular dependenceHumanitiesParticle Physics - Experiment
researchProduct

Development of new CdZnTe detectors for room-temperature high-flux radiation measurements

2017

Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room-temperature X-ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling-heater-method (THM)-grown CZT detectors, recently developed at IMEM-CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm−2 at 1000 V cm−1), a…

Nuclear and High Energy PhysicsPreamplifier02 engineering and technologydigital pulse shape analysiRadiation01 natural scienceslaw.inventionPlanarOpticstravelling heater methodlaw0103 physical scienceshigh fluxInstrumentationenergy-resolved photon-counting detectorsNuclear and High Energy PhysicPhysicsRadiationdigital pulse shape analysis010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorDetectorSettore FIS/01 - Fisica SperimentaleX-ray and γ-ray detectorenergy-resolved photon-counting detector021001 nanoscience & nanotechnologyCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Anodegold electroless contactFull width at half maximumX-ray and -ray detectors0210 nano-technologybusinessVoltage
researchProduct

Forward production of charged pions with incident protons on nuclear targets at the CERN Proton Synchrotron

2009

et al.

Nuclear and High Energy PhysicsProtonHadronchemistry.chemical_elementProton Synchrotronddc:500.201 natural sciences7. Clean energyNuclear physics0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Nuclear interaction lengthNuclear Experiment010306 general physicsHARPPhysicsLarge Hadron Collider010308 nuclear & particles physicsFísicaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryBeamlinePhysics::Accelerator PhysicsHigh Energy Physics::ExperimentBerylliumAtomic physicsParticle Physics - Experiment
researchProduct

ESR dosimeter material properties of phenols compound exposed to radiotherapeutic electron beams

2017

Abstract There is a need for a sensitive dosimeter using Electron Spin Resonance spectroscopy for use in medical applications, since non-destructive read-out and dose archival could be achieved with this method. This work reports a systematic ESR investigation of IRGANOX ® 1076 exposed to clinical electron beams produced by a LINAC used for radiation therapy treatments. Recently, dosimetric features of this material were investigated for irradiation with 6 0Co γ -photons and neutrons in both pellet and film shape and have been found promising thanks to their high efficiency of radiation-matter energy transfer and radical stability at room temperature. Here the analysis of the dosimetric fea…

Nuclear and High Energy PhysicsRange (particle radiation)DosimeterMaterials scienceSettore FIS/01 - Fisica SperimentaleAnalytical chemistryElectronStopping powerSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Settore FIS/03 - Fisica Della Materia030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineNuclear magnetic resonanceSettore ING-IND/23 - Chimica Fisica Applicatalaw030220 oncology & carcinogenesisAbsorbed doseIrradiationDosimetry Dose ESR EPR Electron BeamElectron paramagnetic resonanceInstrumentationBeam (structure)
researchProduct

ESR response of phenol compounds for dosimetry of gamma photon beams

2014

Abstract In the present paper we investigate the features of IRGANOX® 1076 phenols as a material for electron spin resonance (ESR) dosimetry. We experimentally analyzed the ESR response of pellets of IRGANOX® 1076 phenols irradiated with 60Co photons. The best experimental parameters (modulation amplitude and microwave power) for dosimetric applications have been obtained. The dependence of ESR signal as function of γ dose is found to be linear in the dose range studied (12–60 Gy) and the lowest measurable dose is found to be of the order of 1 Gy. The signal after irradiation is very stable in the first thirty days. From the point of view of the tissue equivalence, these materials have mass…

Nuclear and High Energy PhysicsRange (particle radiation)PhotonPhenolChemistryAnalytical chemistrySignalSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)law.inventionNuclear magnetic resonanceAmplitudelawAttenuation coefficientElectron spin resonanceDosimetryDosimetryPhoton beamIrradiationElectron paramagnetic resonanceInstrumentation
researchProduct

ESR response of watch glasses to proton beams

2010

In this paper we have analyzed the electron spin resonance (ESR) signal of watch glasses irradiated with %60 MeV proton beams in the dose range between 1 and 105 Gy. The composition of samples expressed in oxides weight percentages has been obtained carrying out X-ray fluorescence spectrometry (XRF) mea- surements. The ESR signal has been studied in terms of its dependence on microwave power and modulation field in order to choose the optimal recording parameters. The dependence of the radioinduced signal on the exposure dose has been investigated. A numerical procedure aimed at improving the sensitivity in the low dose range has been developed.

Nuclear and High Energy PhysicsRange (particle radiation)ProtonChemistryFluorescence spectrometryAnalytical chemistryResonanceSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)law.inventionProton beamlawIrradiationElectron paramagnetic resonanceSpectroscopyInstrumentationMicrowaveESRWatch glasseNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct