Search results for "Benzene"

showing 10 items of 1701 documents

Life-time studies with capillary electrochromatography columns operated under different conditions.

2000

A test system has been established to permit the monitoring of the life-time performance of several reversed- phase capillary electrochromatography (CEC) columns. The retention factors, k(cec), peak symmetry coefficients, lambda(sym), and column efficiencies, N, of three neutral n-alkylbenzene analytes, namely ethyl-, n-butyl- and n-pentylbenzenes, were determined for Hypersil 3 microm n-octylsilica and n-octadecylsilica packed into CEC capillary columns of 100 microm I.D., with a packed length of 250 mm, and a total length of 335 mm. The performances of these CEC capillary columns were examined for a variety of eluents with pH values ranging between pH 2.0 - 8.0, similar to those employed …

chemistry.chemical_classificationCapillary electrochromatographyChromatographyCapillary actionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyHydrocarbonchemistryElectrochromatographyAlkylbenzenesTheoretical plateChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Modelling retention and peak shape of small polar solutes analysed by nano-HPLC using methacrylate-based monolithic columns.

2019

Abstract The development of methacrylate-based monolithic columns was studied for the separation of pharmaceutical hydrophilic compounds in nano-liquid chromatography. The selected polymerisation mixture consisted of 7.5% hexyl methacrylate, 4.5% methacrylic acid and 18.0% ethylene dimethacrylate (w/w), in a binary porogenic solvent (35:35 w/w 1-propanol/1,4-butanediol). The polymer synthesised with this mixture has a good permeability, not excessive back-pressure, and reasonable retention times for polar and non-polar solutes. Monolithic columns (12 cm total capillary length, 100 μm i.d.), prepared with this mixture, were able to produce hydrogen bonding and electrostatic interactions, giv…

chemistry.chemical_classificationChromatography010401 analytical chemistry02 engineering and technologyPolymer021001 nanoscience & nanotechnologyMethacrylate01 natural sciencesBiochemistryHigh-performance liquid chromatography0104 chemical sciencesAnalytical ChemistrySolventchemistry.chemical_compoundchemistryMethacrylic acidEnvironmental ChemistryAlkylbenzenesParticle size0210 nano-technologySelectivitySpectroscopyAnalytica chimica acta
researchProduct

Headspace-Liquid Phase Microextraction for Attenuated Total Reflection Infrared Determination of Volatile Organic Compounds at Trace Levels

2010

A combination of headspace (HS) sampling and liquid phase microextraction (LPME) has been successfully developed to solve sensitivity problems in attenuated total reflection (ATR) infrared determination of volatile organic compounds (VOCs). The HS sampling facilitates the selective extraction of the target volatile analytes from the sample matrix, while the liquid phase microextraction allows their preconcentration prior to infrared analysis. The direct determination of extracted analytes in the acceptor solvent provides high preconcentration factors of the order of 200 with a reduced consumption of organic solvents and a minimum generation of wastes, being thus the developed methodology a …

chemistry.chemical_classificationChromatographyExtraction (chemistry)XyleneAnalytical chemistryTolueneAnalytical ChemistrySolventchemistry.chemical_compoundchemistryAttenuated total reflectionVolatile organic compoundSample preparationBenzeneAnalytical Chemistry
researchProduct

Separation of polycyclic aromatic hydrocarbons under isocratic conditions by a column switching technique

1994

A simple and efficient method of separating a 20-component PAH-mixture (RSM 1647 standard mixture +benzene, toluene, perylene and coronene) by RP-HPLC is described. Separation was by using two Superspher-100 RP-18 cartridges thermostatted at different temperatures under isocratic conditions with water-acetonitrile eluent. The analysis time with complete resolution of all components can be reduced to 15 min.

chemistry.chemical_classificationChromatographyOrganic ChemistryClinical BiochemistryAnalytical chemistryBiochemistryTolueneHigh-performance liquid chromatographyCoroneneAnalytical Chemistrychemistry.chemical_compoundCartridgeColumn chromatographyHydrocarbonchemistryBenzenePeryleneChromatographia
researchProduct

Preparation of monodisperse polyethylene oxides by gel permeation chromatography of discontinuous polymer-homologous series

1970

Abstract Starting from triethylene glycol, monodisperse polyethylene oxides of a molecular weight (MW) up to 2000 (degree of polymerisation (DP) During the first step the ditosylate of triethylene glycol is reacted with the sodium alkoxide of the same diol at room temperature. The condesation product (polymer homologues of triethylene glycol) was separated by molecular distillation and yielded the pure oligomers nonaethylene glycol (DP = 9, MW 414) and pentadecaethylene glycol (DP = 15, MW = 678), as proved by gel chromatography. During the next step the polymer homologues of nonaethylene glycol were synthesised in a similar way. The pure oligomers hepteicosa (DP = 27, MW = 1207) and pentat…

chemistry.chemical_classificationChromatographyOrganic ChemistryDispersityDiolGeneral MedicinePolymerDivinylbenzeneBiochemistryAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundchemistryPolymerizationPolymer chemistryPolystyreneTriethylene glycolJournal of Chromatography A
researchProduct

Determination of indoor air quality of a phytosanitary plant.

2011

A new methodology has been developed to determine volatile organic compounds (VOCs) and pesticides in ambient air using membrane based devices as passive samplers. Pesticides were determined by gas chromatography with mass spectrometry detection (GC-MS) after their microwave-assisted extraction (MAE) from the passive sampler and the required clean-up. On the other hand, VOCs were also caught with the same samplers and directly determined by head space (HS) coupled to GC-MS. The use of samplers filled with florisil and activated carbon allows us to catch with a simple device both, VOCs and pesticides, with a high vapor pressure. Results obtained in the deployment of samplers in different sit…

chemistry.chemical_classificationChromatographyXylenePesticideBiochemistryEthylbenzeneAnalytical Chemistrychemistry.chemical_compoundIndoor air qualitychemistryEnvironmental chemistrymedicineEnvironmental ChemistryVolatile organic compoundGas chromatographyAir quality indexSpectroscopyActivated carbonmedicine.drugAnalytica chimica acta
researchProduct

PNIPAM Copolymers Containing Light-Responsive Chromophores: A Method Toward Molecular Logic Gates

2010

A series of thermo-responsive PNIPAM copolymers containing different amounts of fulgimide moieties has been synthesized via a polymer analogous reaction of poly(pentafluorophenyl acrylate). All copolymers were designed to exhibit a lower critical solution temperature (LCST) in water, which was only weakly dependent on the amount of incorporated chromophoric fulgimide groups. The copolymers showed a photocyclization of the fulgimide side groups upon irradiation with UV-light accompanied with a color change. The closed form of the chromophore had a halftime of 136 min for the visible reisomerization and did not affect the LCST of the polymer. This led to the realization of a logic "NOT A" for…

chemistry.chemical_classificationCloud pointAcrylateAqueous solutionPolymers and PlasticsChemistryOrganic ChemistryPolymerChromophorePhotochemistryLower critical solution temperaturechemistry.chemical_compoundAzobenzenePolymer chemistryMaterials ChemistryCopolymerMacromolecular Rapid Communications
researchProduct

N-(2-Benzoyl-4-chlorophenyl)-4-chlorobenzenesulfonamide

2008

The title compound, C19H13Cl2NO3S, is an N-arylsulfonyl derivative of 2-amino-5-chlorobenzophenone. The compound is biologically active and shows potential to be utilized as an inhibitor of CCR2 and CCR9 receptor functions. In the crystal structure, there is an intramolecular N—H...O hydrogen bond between the amide and carbonyl groups. The benzoyl and 4-chlorophenyl groups form intramolecular and intermolecular face-to-face contacts, with a dihedral angle of 10.6 (1)° between their mean planes in both cases, and centroid–centroid separations of 4.00 (1) and 4.25 (1) Å for the intra- and intermolecular interactions, respectively.

chemistry.chemical_classificationCrystallographyHydrogen bondGeneral ChemistryCrystal structureDihedral angleCondensed Matter PhysicsBioinformaticsOrganic PapersMedicinal chemistrySulfonamidechemistry.chemical_compoundchemistryQD901-999AmideBenzophenoneGeneral Materials ScienceBenzeneDerivative (chemistry)Acta Crystallographica Section E Structure Reports Online
researchProduct

Optical planar Bragg grating sensor for real-time detection of benzene, toluene and xylene in solvent vapour

2012

Abstract We report on an optical planar Bragg grating sensor functionalized by a comparatively simple method to detect substances such as benzene, toluene and xylene (BTX). The functionalization is performed by allyl substituted γ -cyclodextrin derivatives which are immobilized on the sensor surface by dip coating. Our results prove the capability of this functionalized sensor system to detect lowest concentrations of BTX in solvent vapour in real-time with a sensitivity of 3±0.4 pm/100 ppm for benzene, 8±1 pm/100 ppm for toluene and 32±1 pm/100 ppm for m-xylene. Taking into account the spectral resolution and repeatability of the interrogation system this corresponds to a minimum concentra…

chemistry.chemical_classificationCyclodextrinChemistryXyleneMetals and AlloysAnalytical chemistryCondensed Matter PhysicsTolueneDip-coatingSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsSolventchemistry.chemical_compoundFiber Bragg gratingMaterials ChemistrySurface modificationElectrical and Electronic EngineeringBenzeneInstrumentationSensors and Actuators B: Chemical
researchProduct

Spectrophotometric determination of binding constants between some aminocyclodextrins and nitrobenzene derivatives at various pH values

2002

Abstract The inclusion capacity of three modified cyclodextrins—namely mono-(6- N , N -dimethylamino-6-deoxy)- ( 3 ), mono-6-(2-aminoethyl)-amino-6-deoxy- ( 4 ) and mono-6-(2- N , N -dimethylaminoethyl)-amino-6-deoxy- ( 5 ) β-cyclodextrin, with six para -substituted nitrobenzenes ( A – F ) has been investigated at three different pH values. Molecular interactions in inclusion complexes have also been investigated by means of molecular mechanics (MM2/QD) models. The desolvation of the cyclodextrin is the most important factor in determining the binding ability of the various hosts. However, for a given host, electrostatic and van der Waals interactions and the formation of a hydrogen bond be…

chemistry.chemical_classificationCyclodextrinHydrogen bondOrganic ChemistrySettore CHIM/06 - Chimica OrganicaBiochemistryBinding constantMedicinal chemistryMolecular mechanicscyclodextrins inclusion molecular mechanicsNitrobenzenesymbols.namesakechemistry.chemical_compoundchemistryComputational chemistryDrug DiscoverysymbolsNon-covalent interactionsDesolvationvan der Waals force
researchProduct