Search results for "Biceps"

showing 10 items of 87 documents

2020

Background: We prospectively tested technical feasibility and clinical outcome of percutaneous ultrasound-guided tenotomy of long head of biceps tendon (LHBT). Methods: We included 11 patients (6 women; age: 73 ± 8.6 years) with symptomatic full-thickness rotator cuff tear and intact LHBT, in whom surgical repair was not possible/refused. After ultrasound-guided injection of local anesthetic, the LHBT was cut with a scalpel under continuous ultrasound monitoring until it became no longer visible. Pain was recorded before and at least six months after procedure. An eight-item questionnaire was administered to patients at follow-up. Results: A median of 4 tendon cuts were needed to ensure com…

030222 orthopedicsmedicine.medical_specialtyPercutaneousbusiness.industryLocal anestheticmedicine.drug_classmedicine.medical_treatmentTenotomyGeneral MedicineBiceps030218 nuclear medicine & medical imagingTendonSurgery03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureDeformityMedicineRotator cuffmedicine.symptomProspective cohort studybusinessJournal of Clinical Medicine
researchProduct

Changes in isokinetic torque and muscular activity of elbow flexors muscles with age

2001

This study examined the influence of aging on torque-angular velocity relationships for elbow flexion and the corresponding muscular activity levels in order to target the mechanisms involved in the eccentric muscle action in older adults. Maximal constant angular torque (CAT) at 90 degrees was measured at different angular velocities for concentric (CON; 60, 120, 180, 240 degrees s(-1)), isometric (ISO) and eccentric (ECC; -60, -120 degrees s(-1)) elbow flexor muscle actions in older (OG; 6 females and 4 males, 64-82 years) and young adult subjects (YG; 6 females, 6 males, 19-24 years) on an isokinetic dynamometer. Myoelectrical activity was quantified on biceps and triceps muscles, using …

AdultMaleAginggenetic structuresElbowIsometric exerciseElectromyographyConcentricBiochemistryBicepsEndocrinologyMuscle actionElbowGeneticsHumansMedicineEccentricMuscle SkeletalMolecular BiologyAgedAged 80 and overmedicine.diagnostic_testElectromyographybusiness.industryCell BiologyAnatomyMiddle Agedmedicine.anatomical_structureTorqueFemaleIsokinetic torquebusinessExperimental Gerontology
researchProduct

STRENGTH AND POWER PROFILES OF THE LOWER AND UPPER EXTREMITIES IN MASTER THROWERS AT DIFFERENT AGES

2007

Ojanen, T., T. Rauhala, and K. Hakkinen. Strength and power profiles of the lower and upper extremities in master throwers at different ages. J. Strength Cond. Res. 21(1):216-222. 2007.-Thirty-two master athletes (shot put, discus, and hammer throw) were divided into 4 groups according to their age (T40 [40 years of age], 50 [50 years of age], 60 [60 years of age], and 75 [75 years of age]). Twenty-eight age-matched men served as controls (C40 [40 years of age], 50 [50 years of age], 60 [60 years of age], and 75 [75 years of age]). The subjects were tested for maximal isometric strength of the lower and upper extremities. Power was measured by performing jump squats and bench press in the S…

AdultMaleAgingmedicine.medical_specialtyStrength trainingRepetition maximumPhysical Therapy Sports Therapy and RehabilitationIsometric exerciseMuscle massBench pressHumansMedicineOrthopedics and Sports MedicineMuscle StrengthMuscle SkeletalAgedOrthodonticsAnalysis of VarianceLegElectromyographybusiness.industryTrack and FieldBiceps curlAge FactorsGeneral MedicineMiddle AgedShot putArmPhysical therapybusinessThrowingJournal of Strength and Conditioning Research
researchProduct

Withdrawal reflex organisation to electrical stimulation of the dorsal foot in humans.

2001

The present study investigated excitatory reflex receptive fields for various muscle reflex responses and reflex mediated ankle joint movements using randomised electrical stimulation of the dorsal and plantar surface of the foot in 12 healthy subjects. Eleven electrodes (0.5-cm2 cathodes) were mounted on the dorsal side and three on the plantar side of the foot. A low (1.5 times pain threshold) and a high (2.3 times pain threshold) stimulus intensity were used to elicit the reflexes. EMG signals were recorded from tibialis anterior (TA), gastrocnemius medialis (GM), soleus (SO), biceps femoris (BF), and rectus femoris (RF) muscles together with the ankle movement measured by a goniometer. …

AdultMaleHeelMovementWithdrawal reflexPainElectromyographyBicepsThreshold of painReflexReaction TimeMedicineHumansMuscle SkeletalSkinmedicine.diagnostic_testbusiness.industryElectromyographyFootGeneral NeuroscienceNociceptorsAnatomyMiddle AgedElectric Stimulationmedicine.anatomical_structureReceptive fieldReflexFemaleAnkleTibial NervebusinessAnkle JointExperimental brain research
researchProduct

Human isometric force production and electromyogram activity of knee extensor muscles in water and on dry land.

1999

This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both th…

AdultMaleKnee JointPhysiologyVastus medialisIntraclass correlationIsometric exerciseElectromyographyBicepsIsometric ContractionMedicineHumansMuscle SkeletalHydrotherapyReproducibilityKnee extensorsmedicine.diagnostic_testbusiness.industryElectromyographyPublic Health Environmental and Occupational HealthReproducibility of ResultsWaterAnatomyElectrophysiologyFemalebusinessBiomedical engineeringEuropean journal of applied physiology and occupational physiology
researchProduct

Effects of muscle – tendon length on joint moment and power during sprint starts

2005

The aim of this study was to examine the effects of muscle-tendon length on joint moment and power during maximal sprint starts. Nine male sprinters performed maximal sprint starts from the blocks that were adjusted either to 40 degrees or 65 degrees to the horizontal. Ground reaction forces were recorded at 833 Hz using a force platform and kinematic data were recorded at 200 Hz with a film camera. Joint moments and powers were analysed using kinematic and kinetic data. Muscle - tendon lengths of the medial gastrocnemius, soleus, vastus medialis, rectus femoris and biceps femoris were calculated from the set position to the end of the first single leg contact. The results indicated that bl…

AdultMaleKnee JointVastus medialisAccelerationPhysical Therapy Sports Therapy and RehabilitationGeometryKinematicsBicepsRunningTendonsmedicineHumansOrthopedics and Sports MedicineForce platformGround reaction forceMathematicsAustraliaBiomechanicsAnatomyBiomechanical PhenomenaTendonmedicine.anatomical_structureSprintHip JointAnkle JointJournal of Sports Sciences
researchProduct

Electromechanical delay in human skeletal muscle under concentric and eccentric contractions.

1979

In contraction of skeletal muscle a delay exists between the onset of electrical activity and measurable tension. This delay in electromechanical coupling has been stated to be between 30 and 100 ms. Thus, in rapid movements it may be possible for electromyographic (EMG) activity to have terminated before force can be detected. This study was designed to determine the dependence of the EMG-tension delay upon selected initial conditions at the time of muscle activation. The right forearms of 14 subjects were passively oscillated by a motor-driven dynamometer through flexion-extension cycles of 135 deg at an angular velocity of approximately equal to 0.5 rad/s. Upon presentation of a visual s…

AdultMaleLightPhysiologyMovementBrachioradialisIsometric exerciseConcentricBicepsPhysiology (medical)medicineEccentricHumansOrthopedics and Sports MedicinePhysicsMusclesPublic Health Environmental and Occupational HealthSkeletal muscleGeneral MedicineAnatomyElectrophysiologyElectrophysiologymedicine.anatomical_structuremedicine.symptomBiomedical engineeringMuscle contractionMuscle ContractionEuropean journal of applied physiology and occupational physiology
researchProduct

Kinetic and electromyographic analysis of single repetition constant and variable resistance leg press actions

2010

During a multi-joint leg press action, maximal force capabilities increase with increasing knee angle. In typical resistance exercises, constant resistance is used, which does not stress the neuromuscular system at large knee angles. The purpose of this study was to compare constant and variable resistance settings using a range of contraction loads and velocities. Nine healthy, untrained males performed single contractions using four different resistance settings (constant resistance, two settings that increased resistance at large knee angles and one setting that reduced resistance at large knee angles). Single contractions using 40%, 60%, and 80% of one repetition maximum with both stead…

AdultMaleMaterials scienceKnee JointVastus medialisPhysical ExertionBiophysicsNeuroscience (miscellaneous)ElectromyographyConcentricBicepsOne-repetition maximummedicineHumansMuscle Skeletalta315Leg pressmedicine.diagnostic_testElectromyographyResistance TrainingAnatomyAdaptation PhysiologicalKineticsLarge kneeNeurology (clinical)Range of motionMuscle ContractionBiomedical engineeringJournal of Electromyography and Kinesiology
researchProduct

Effect of innervation zones in estimating biceps brachii force-EMG relationship during isometric contraction

2012

Measuring muscle forces in vivo is invasive and consequently indirect methods e.g., electromyography (EMG) are used in estimating muscular force production. The aim of the present paper was to examine what kind of effect the disruption of the physiological signal caused by the innervation zone has in predicting the force/torque output from surface EMG. Twelve men (age 26 (SD ±3)years; height 179 (±6)cm; body mass 73 (±6)kg) volunteered as subjects. They were asked to perform maximal voluntary isometric contraction (MVC) in elbow flexion, and submaximal contractions at 10%, 20%, 30%, 40%, 50% and 75% of the recorded MVC. EMG was measured from biceps brachii muscle with an electrode grid of 5…

AdultMaleMean squared errorintervation zonePhysical Exertionta221BiophysicsNeuroscience (miscellaneous)Isometric exerciseElectromyographyBicepsElectrode GridSensitivity and SpecificityRoot mean squareIsometric ContractionElbow JointmedicineMuscular forceHumansMuscle StrengthMuscle Skeletalta315ta218MathematicsOrthodonticsvalidationta214medicine.diagnostic_testta114ElectromyographyReproducibility of ResultsmodelingAnatomybody regionsNeurology (clinical)Stress Mechanicalhigh-density EMGneuromuscularLeave one out methodAlgorithmsJOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY
researchProduct

Effect of electrode location on surface electromyography changes due to eccentric elbow flexor exercise.

2009

Experiments were carried out to determine whether the location of electrodes has an effect on eccentric exercise–induced changes in surface electromyography (sEMG) variables in the biceps brachii muscle. sEMG signals were recorded with a grid of 64 electrodes before and up to 4 days post-exercise. Root mean square (RMS) and mean power frequency (MNF) were calculated for: (1) each channel; (2) as an average of all channels; and (3) as an average of individual channel rows and columns. Mean muscle-fiber conduction velocity (CV) was estimated similarly but was based on double-differential channels. Maximal isometric voluntary torque decreased 21.3 ± 5.6% post-exercise. The average sEMG variabl…

AdultMalePhysiologyMuscle Fibers SkeletalPainElectromyographyIsometric exerciseNerve conduction velocityRoot mean squareCellular and Molecular NeurosciencePhysiology (medical)Isometric ContractionmedicineElbowEccentricHumansMuscle SkeletalElectrodesExerciseMathematicsMuscle fatiguemedicine.diagnostic_testBiceps brachii muscleElectromyographySignal Processing Computer-AssistedAnatomyElectrode locationNeurology (clinical)Biomedical engineeringMuscle ContractionMusclenerve
researchProduct