Search results for "Biocompatible Material"
showing 10 items of 290 documents
Collagen membranes of dermal and pericardial origin-In vivo evolvement of vascularization over time.
2020
Aim of the study was to compare the evolvement of vascularization over time of collagen membranes (CMs) of dermal and pericardial origin in an in vivo animal study. Twenty-eight mice underwent implantation of three commercially available CM derived from porcine dermis (homogenous structure: CM1 (Control 1) and bilayer structure: CM2 [Control 2]), from porcine pericardium (CM3; Test 1) as well as CM3 sprayed with silica-enhanced nanostructured hydroxyapatite (CM4, Test 2). After 3, 6, 9, and 12 days, intravital fluorescence microscopy was conducted for determination of capillary diameter, density, flow, and length. At Day 12, samples were examined immunohistologically for expression of fibro…
Human periodontal fibroblast response to a nanostructured hydroxyapatite bone replacement graft in vitro
2007
Abstract Objective The efficacy of nanostructured hydroxyapatite (NHA) for the treatment of osseous defects has been demonstrated in recent studies, even though the underlining biological mechanism is still poorly known. This study examined the alterations in cellular adhesion and mitogenic responses in human periodontal ligament (PDL) cells treated with a novel nanostructured hydroxyapatite bone graft substitute and characterized associated changes in cellular signalling pathways. Methods Cultured PDL cells were stimulated with NHA in a surface coated form. Proliferation was determined by bromodeoxyuridine (BrdU) incorporation and cell adhesion was analysed by a colorimetric assay. In orde…
A New Prosthetic Implant for Inguinal Hernia Repair: Its Features in a Porcine Experimental Model
2011
Even after more than 100 years of inguinal hernia repair, the rate of complications and recurrence remains unacceptably high. In the last decades, few effective advances in surgical technique and materials have been made. The authors see them as minor adjustments in the shape and materials of the prosthetic implants. Still, the underlying genesis of inguinal hernia remains undefined. Based upon this, it seems the surgical repair of inguinal protrusions cannot be based upon the pathogenesis because the etiology to date has not been addressed. Most hernia repairs are performed with some degree of point fixation (sutures/tacks) to stop the mesh from migrating and creating high recurrence rates…
Toxicity of used orthodontic archwires assessed by three-dimensional cell culture
2006
The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n = 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lower archwires were collected and subjected to two different protocols: to assess toxicity, two pieces of each wire were placed on 3D cell cultures (reconstituted human epithelium); to investigate the possibility of cell damage, the 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl tetrazolium bromide (MTT) ass…
Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible
2013
Introduction: After ablative surgery of the mandible, angular stable alloplastic reconstruction plates are commonly employed. The aim of the study was a long-term evaluation of local anatomical, as looking at systemic factors influencing specific complications and the failure rate of such plates. Materials and methods: In a retrospective study covering an 11-year period, we reviewed the outcomes of angular stable plates of patients who had a segmental resection of the mandible and subsequent alloplastic reconstruction. Complications and failure rates were assessed and local (anatomical size and localization of resection) as well as systemic risk factors (age, sex, radiation therapy, smoking…
Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases
2010
Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…
Enzyme-based biosilica and biocalcite: biomaterials for the future in regenerative medicine
2013
The oldest animals on Earth, sponges, form both the calcareous and the siliceous matrices of their spicules enzymatically. Until recently, it has been neglected that enzymes play crucial roles during formation of these biominerals. This paradigm shift occurred after the discovery that the enzyme silicatein, which catalyzes the polycondensation of silica, and the enzyme carbonic anhydrase (CA), which catalyzes the formation of bicarbonate (HCO3(-)/CaCO3), produce solid amorphous bioglass or biocalcite. This suggests that in mammals, biosilica and biocalcite can act anabolically during hydroxyapatite (HA) synthesis and bone formation. Biosilica and biocalcite are thus promising candidates for…
Degradable poly(amidoamine) hydrogels as scaffolds for in vitro culturing of peripheral nervous system cells.
2012
This paper reports on the synthesis and physico-chemical, mechanical, and biological characterization of two sets of poly(amidoamine) (PAA) hydrogels with potential as scaffolds for in vivo peripheral nerve regeneration. They are obtained by polyaddition of piperazine with N,N′-methylenebis(acrylamide) or 1,4-bis(acryloyl)piperazine with 1,2-diaminoethane as cross-linking agent and exhibit a combination of relevant properties, such as mechanical strength, biocompatibility, biodegradability, ability to induce adhesion and proliferation of Schwann cells (SCs) preserving their viability. Moreover, the most promising hydrogels, that is those deriving from 1,4-bis(acryloyl)piperazine, allow the …
Influence of different parameters on drug release from hydrogel systems to a biomembrane model. Evaluation by differential scanning calorimetry techn…
2000
A comparative study on the drug release capacity of four water swellable polymeric systems was carried out by differential scanning calorimetry (DSC). The polymeric systems chosen were alpha,beta-polyaspartahydrazide (PAHy) crosslinked by glutaraldehyde (GLU) (PAHy-GLU) or by ethyleneglycoldiglycidylether (EGDGE), (PAHy-EGDGE), polyvinylalcohol (PVA) crosslinked by glutaraldehyde (PVA-GLU) and alpha,beta-poly(N-hydroxyethyl)-DL-aspartamide (PHEA) by gamma irradiation (PHEA-gamma matrices). The degree of crosslinking for PAHy-GLU, PAHy-EGDGE and PVA-GLU samples was about 0.4 and 0.8. These hydrogels were characterized as free of drugs and were loaded with diflunisal (DFN) (approximately 2.5%…
Effect of media composition on long-term in vitro stability of barium alginate and polyacrylic acid multilayer microcapsules.
2000
For a number of applications stability of microcapsules is a critical factor. Since the maintenance of polyelectrolyte complexes depends considerably on the ion composition we tested the physical properties of barium alginate capsules and searched for conditions to improve stability by a multilayer coating with polyethylenimine (PEI) and polyacrylic acid (PAA). Mechanical stability and diameters were determined in barium alginate capsules and compared with multilayer capsules. Multilayer coating resulted in smaller capsules than barium complexing alone. The difference was more pronounced when CaCl2 was used instead of NaCl during coating. Barium alginate capsules and application of CaCl2 du…