Search results for "Bioengineering"
showing 10 items of 1963 documents
Bioresource technology for bioenergy, bioproductsenvironmental sustainability.
2022
The 3rd International Conference for Bioresource Technology for Bioenergy, Bioproducts & Environmental Sustainability (BIORESTEC) was held online from 17 to 19 May 2021. More than 120 participants from all over the world participated in this conference. The conference was studded with nine plenary lectures, ten invited lectures as well as more than 50 oral presentations along with several poster presentations. The purpose of the conference was to foster the exchange of knowledge and ideas among researchers in academia and industry as well as policymakers working on various aspects of biorefinery to discuss the progress made during the intervening three years and the latest trends in bio…
Real-time estimation of plasma insulin concentration from continuous glucose monitor measurements
2015
Continuous glucose monitors can measure interstitial glucose concentration in real time for closed-loop glucose control systems, known as artificial pancreas. These control systems use an insulin feedback to maintain plasma glucose concentration within a narrow and safe range, and thus to avoid health complications. As it is not possible to measure plasma insulin concentration in real time, insulin models have been used in literature to estimate them. Nevertheless, the significant interand intra-patient variability of insulin absorption jeopardizes the accuracy of these estimations. In order to reduce these limitations, our objective is to perform a real-time estimation of plasma insulin co…
Extensive Assessment of Blood Glucose Monitoring During Postprandial Period and Its Impact on Closed-Loop Performance.
2017
[EN] Background: Closed-loop (CL) systems aims to outperform usual treatments in blood glucose control and continuous glucose monitors (CGM) are a key component in such systems. Meals represents one of the main disturbances in blood glucose control, and postprandial period (PP) is a challenging situation for both CL system and CGM accuracy. Methods: We performed an extensive analysis of sensor¿s performance by numerical accuracy and precision during PP, as well as its influence in blood glucose control under CL therapy. Results: During PP the mean absolute relative difference (MARD) for both sensors presented lower accuracy in the hypoglycemic range (19.4 ± 12.8%) than in other ranges (12.2…
PsychDT Working Group
2015
Background: Diabetes technology is a cornerstone of diabetes management in the 21st century, with advances in available devices over recent years playing a central role in the way that health care has progressed. Psychosocial interventions have been shown to have a positive impact on glycemic control, reduce psychological distress and reduce costs of health care. Addressing and improving psychosocial outcomes that complement biomedical improvements and looking to the future are crucial to enhance patient acceptance of artificial pancreas (AP) systems. Methods: To achieve closer collaboration and comparability across different AP research trials, a working group was established. Results: Exi…
Intraportal transplantation of allogenic pancreatic islets encapsulated in barium alginate beads in diabetic rats.
2003
The survival of microencapsulated islets transplanted into the unmodified peritoneal cavity is limited, even if capsular overgrowth is restricted to a minimum, due to an insufficient oxygen supply to the islets. Therefore, research efforts should focus on finding or creating a transplantation site, which permits a closer contact between the encapsulated islets and the blood. For this reason, the liver could be an interesting candidate. The aim of the present study was to test the hypothesis that the intraportal transplantation of allogenic islets encapsulated in small-sized barium alginate beads is safe and succeeds to induce normoglycemia in diabetic rats. The intraportal transplantation o…
Clinical Approach to Flash Glucose Monitoring: An Expert Recommendation
2019
The flash glucose monitoring (FGM) system FreeStyle Libre® is a device that measures interstitial glucose in a very simple way and indicates direction and speed of glucose change. This allows persons with diabetes to prevent hypoglycemic and hyperglycemic events. Scientific evidence indicates that the system can improve glycemic control and quality of life. To obtain the maximum benefit, it is necessary to properly handle glucose values and trends. Due to the generalization of the system use, the purpose of the document is to provide recommendations for the optimal use of the device, not only in the management of glucose values and trends but also in the prevention of hypoglycemia, actuati…
Glycemic Variability Assessment with a 14-Day Continuous Glucose Monitoring System: When and How Long to Measure MAGE (Mean Amplitude of Glucose Excu…
2021
Mean amplitude of glucose excursion (MAGE) is considered as the “gold standard” for assessing the short-term within-day glycemic variability (GV), which is an important component of overall glycemic control. A 14-day continuous glucose monitoring system is now widely used and allows easier assessment of GV. However, it is still unknown whether MAGE, usually calculated on a 48-hour period is identical whatever the time during the 14-day lifespan of the sensor and whether a longer time period might give additional information. We evaluated in 68 patients with type 1 diabetes, MAGE during three 2-day periods (day1-day3; day6-day8; day11-day13) and during periods of 3 days and 4 days. MAGE cal…
Psychosocial Aspects of Continuous Glucose Monitoring
2016
Continuous glucose monitoring (CGM) systems provide people with diabetes with valuable real-time information on glucose trajectories and trends, thus offering opportunities for improving diabetes self-management. Ample evidence from clinical trials underscores CGM effectiveness for biomedical outcomes including HbA1C and hypoglycemia. However, interindividual variability in CGM uptake seems to be substantial: Neither do all individuals with diabetes adopt CGM readily in their diabetes self-management, nor do all of them benefit from CGM. In this article, we focus on CGM effects on quality of life and the potential role of psychosocial patient characteristics for determining the uptake and …
Ambulatory Glucose Profile Applied to Flash Glucose Monitoring in Real Life: An Expert Opinion.
2016
The clinical benefits of real time continuous glucose monitoring (rtCGM) use have been well demonstrated in both CSII- and MDI-treated individuals in large clinical trials. However, recommendations for patient use of rtCGM in everyday life situations are lacking. This article provides guidance to clinicians and patients with type 1 diabetes (T1D) in effective use of rtCGM data, including glucose rate of change (ROC) arrows, for insulin dosing adjustments and other treatment decisions. The recommendations presented here are based on our own clinical experiences as endocrinologists, our personal experiences living with T1D using rtCGM, and findings from a recent survey of T1D patients who hav…
Tailoring Novel PTFE Surface Properties: Promoting Cell Adhesion and Antifouling Properties via a Wet Chemical Approach
2016
Many biomaterials used for tissue engineering applications lack cell-adhesiveness and, in addition, are prone to nonspecific adsorption of proteins. This is especially important for blood-contacting devices such as vascular grafts and valves where appropriate surface properties should inhibit the initial attachment of platelets and promote endothelial cell colonization. As a consequence, the long-term outcome of the implants would be improved and the need for anticoagulation therapy could be reduced or even abolished. Polytetrafluoroethylene (PTFE), a frequently used polymer for various medical applications, was wet-chemically activated and subsequently modified by grafting the endothelial …