Search results for "Biomaterials and bioengineering in Dentistry"
showing 10 items of 79 documents
Effect of adhesive layers on microshear bond strength of nanocomposite resin to dentin
2016
BACKGROUND Bond strength of adhesive layer can absorb unwanted stresses of polymerization shrinkage in composite resin restorations; increased microshear bond strength can prevent failure of restoration materials, the purpose of this study was to evaluate the effect of adhesive layers on microshear bond strength of nanocomposite resin to dentin. MATERIAL AND METHODS Two different types of adhesive systems: universal adhesive (ExciTE) and newly developed adhesive (Nano-Bond), and one type of light-cured resin restorative material (Nanocomposite resin) were used in this study. The occlusal surfaces of extracted human molar teeth were ground perpendicular to the long axis of each tooth to expo…
Wetting ability of an acetone/based etch rinse adhesive after NaOCl-treatment
2011
Objectives: to evaluate the effect of sodium hypochlorite (NaOCl) treatment on surface dentin roughness (Ra) and contact angle (CA) when using Prime&Bond NT adhesive (PB NT). Study Design: Extracted human third molars were sectioned to expose flat, superficial and deep dentin surfaces. CA and Ra were measured (1) before and (2) after 35% H3PO4 etching, and (3) H3PO4 etching + 5% NaOCl treated for 2 minutes before the application of PB NT. CA was measured by the Axisymmetric Drop Shape Analysis Technique using distilled and deionized water and PB NT. Roughness was evaluated with a profilometer, twelve radial measurements were performed in each treatment surface. Data were analyzed with two-w…
The effect of bacterial cellulose nanocrystals on the shear bond strength of resin modified glass ionomer cement to dentin
2020
Background The present study aimed to investigate the effect of bacterial cellulose nanocrystals (BCNC) on the shear bond strength (SBS) of resin modified glass ionomer cement (RMGIC) to dentin. Material and Methods A total of 48 freshly extracted intact third molars were randomly divided into four main groups with three different concentrations (0.3%, 0.5% and 1% wt) of BCNC with RMGIC and control group without BCNC. These specimens were kept in distilled water at 37° C for 24h. Shear bond strength was examined, using the universal testing machine. Kruskal-Wallis test and Dunn`s post-hoc test were applied for analysis of data. P<0.05 was considered as the level of significance. Results The…
Virtual articulator for the analysis of dental occlusion: An update
2010
The future of dental practice is closely linked to the utilization of computer-based technology, specifically virtual reality, which allows the dental surgeon to simulate true life situations in patients. The virtual articulator has been designed for the exhaustive analysis of static and dynamic occlusion, with the purpose of substituting mechanical articulators and avoiding their errors. These tools will help both odontologists and dental prosthetists to provide the best individualized treatment for each patient. The present review analyzes the studies published in the literature on the design, functioning and applications of virtual articulators. A Medline-PubMed search was made of dental…
History of materials used for recording static and dynamic occlusal contact marks: a literature review
2011
In the discipline of prosthetic dentistry it is important not only to examine the occlusion, but to be able to record, store, and transfer the information. Over the years many occlusion testing materials have been used. It has been suggested the clinical recording and transfer of information using waxes and other occlusion recording materials have disadvantages relating to inaccuracy and problems of manipulation. Therefore, there has been introduction of many new systems for recording occlusion contacts to overcome such problems. The correct physiological recovery of occlusion posses as much a challenge as ever for every dentist and technician. Even the smallest high spots measuring just a …
Peek polymer in orthodontics : a pilot study on children
2017
The purpose of the study has been making the orthodontic space maintainers in PEEK polymer (Polyetheretherketone) through a digital workflow. New digital technologies are taking hold in diagnosis, therapy and in dental laboratories. The digital world can help dentist in diagnosis and therapy: -diagnosis through the acquisition of radiographic images (CBCT) or scanners which allow the creation of 3D digital models - about therapy thanks to dental CAD CAM system. It consists of design devices through an dedicated software CAD and then realize devices through CAM system. We used digital system to improve the quality of the treatment and reduce costs. Peek polymer, subject of studies in recent …
Influence of low concentration acid treatment on lithium disilicate core/veneer ceramic bond strength
2013
Objective: This study evaluated the influence of low concentration acid treatment on the shear bond strength between lithium disilicate (LD) infrastructure and veneering porcelain. The surface morphology characteristic after this acid treatment was also examined. Study Design: LD reinforced ceramic cylinders (n=10) (IPS e.max Press, Ivoclar-Vivadent, Schaan, Liechtenstein) were treated (LD-treated) with a low concentration acid solution (Invex Liquid – Ivoclar-Vivadent, Schaan, Liechtenstein) or not treated with the acid solution (LD-untreated). They were veneered with a glass ceramic (IPS e.max Ceram, Ivoclar-Vivadent, Schaan, Liechtenstein). A metal ceramic group (CoCr) was tested as cont…
Mesenchymal dental stem cells in regenerative dentistry
2012
In the last decade, tissue engineering is a field that has been suffering an enormous expansion in the regenerative medicine and dentistry. The use of cells as mesenchymal dental stem cells of easy access for dentist and oral surgeon, immunosuppressive properties, high proliferation and capacity to differentiate into odontoblasts, cementoblasts, osteoblasts and other cells implicated in the teeth, suppose a good perspective of future in the clinical dentistry. However, is necessary advance in the known of growth factors and signalling molecules implicated in tooth development and regeneration of different structures of teeth. Furthermore, these cells need a fabulous scaffold that facility t…
Platform switching on wide-diameter external hex implants: a finite element analysis.
2012
Objectives: The objective of this work was to use finite element analysis to compare the effect of forces coming to bear on abutments 4.1 or 5.0 mm in diameter connected to a 5.0 mm implant (i.e. with or without platform swit - ching). Study design: A 3D CAD model of a 5 x 11.5 mm external hex implant was developed, complete with a connection screw and either of two abutments, one 4.1 and the other 5 mm in diameter, to assess the influence of two loading conditions, i.e. 200 N loaded either axially or off center on the top of the abutment. Results and conclusions: In the symmetrically loaded models, greater stresses were transmitted to the bone in the area below the neck of the implant in t…
Blood absorption capacity of different xenograft bone substitutes. An in-vitro study
2019
Background Commercially available xenograft blocks, claim to have adequate characteristics to interact with biological media and thus permitting biological fluid absorption. The objective of this in vitro study was to compare the blood absorption capacity of four different xenograft block materials of different composition of collagen and porosity. Material and Methods Four brands of xenograft block materials were used (NuOss®, Bio-Oss®, Osteobiol® and Smartbone®). Five samples of each brand were analyzed, making a total of 20 tests. Human blood was used as the absorption liquid for the present experiment. The time period, in which the block remains in contact with the blood, was registered…