Search results for "Biome"

showing 10 items of 4164 documents

Efficacy of NaOCl/H2O2irrigation and GaAlAs laser in decontamination of root canals in vitro

2003

Background and Objectives To investigate the bactericidal effect of an 809 nm semiconductor laser alone, and in combination with NaOCl/H2O2 irrigation in root canals in vitro. Study Design/Materials and Methods A total of 72 human single-rooted teeth extracted for periodontal reasons were included. The crowns were removed, the roots shortened to a length of 12 mm, and the canals enlarged up to an apical size of #50 file. The specimens were autoclaved and incubated with a suspension of Streptococcus sanguinis (ATCC 10556). Laser irradiation was performed on a PC-controlled XY translation stage. A 200 micron optic fiber was used. Twelve specimens were irradiated at a power output of 1.5, 3.0,…

medicine.medical_specialtyMaterials sciencebusiness.industryScanning electron microscopeRoot canalDentistryDermatologyBacterial growthEndodonticsLaserlaw.inventionmedicine.anatomical_structureDentinal TubulelawHeat generationmedicineSurgeryIrradiationbusinessBiomedical engineeringLasers in Surgery and Medicine
researchProduct

In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung möglicher Anziehung und Erhitzung der Implantate

2000

PURPOSE In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves during MR imaging at 1.5 T. METHODS 17 prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 degrees, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. RESULTS…

medicine.medical_specialtyMaterials sciencemedicine.diagnostic_testmedicine.medical_treatmentMagnetic resonance imagingBiological effectMr imagingProsthesisSurgerymedicine.anatomical_structureFlip anglemedicineRadiology Nuclear Medicine and imagingAcquisition timeHeart valveBiomedical engineeringProsthetic heartRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Nanocapsules generated out of a polymeric dexamethasone shell suppress the inflammatory response of liver macrophages.

2012

Abstract Dexamethasone (DXM) is a synthetic glucocorticoid with anti-inflammatory properties. Targeted delivery of dexamethasone to inflammatory cells, e.g. macrophages and Kupffer cells represents a promising approach to minimize side effects. The aim of the present study was to induce a targeted transport of novel DXM-based biodegradable nanocapsules to phagocytic cells. Nanocapsules (NCs) consisting of a hydroxyethylated glucose polymer (hydroxyethyl starch, HES) shell with encapsulated DXM and NCs synthesized exclusively in inverse miniemulsion out of DXM were investigated. Non-parenchymal murine liver cells served as target cells. HES-DXM NCs were predominantly incorporated by Kupffer …

medicine.medical_specialtyMaterials sciencemedicine.drug_classKupffer CellsInflammatory responseBiomedical EngineeringAnti-Inflammatory AgentsPharmaceutical ScienceMedicine (miscellaneous)BioengineeringStimulationHydroxyethyl starchPharmacologybehavioral disciplines and activitiesNanocapsulesDexamethasoneProinflammatory cytokineHydroxyethyl Starch DerivativesMiceDrug Delivery SystemsNanocapsulesInternal medicinemental disordersmedicineAnimalsGeneral Materials ScienceDexamethasoneCells CulturedMice Inbred C57BLEndocrinologyMolecular MedicineCorticosteroidCytokinesFemaleGlucocorticoidmedicine.drugNanomedicine : nanotechnology, biology, and medicine
researchProduct

Dynamic in vitro dehydration patterns of unworn and worn silicone hydrogel contact lenses.

2008

Purpose: To evaluate the effect of wear on dynamic in vitro dehydration of silicone hydrogel (Si-Hi) contact lens (CL) using a previously described gravimetric procedure. Methods: Five different silicone hydrogel (Si-Hi) contact lenses (CL) were evaluated after being worn by patients under daily wear conditions for 15 days to 1 month. Lenses were conditioned and disinfected with a multipurpose solution after each day of wear. Lenses were left to dehydrate in an analytical balance under controlled conditions of temperature and relative humidity and the results compared with data from new lens samples of the same power and material. Several quantitative parameters were obtained and compared b…

medicine.medical_specialtyMaterials sciencemedicine.medical_treatmentBiomedical EngineeringSiliconeslaw.inventionBiomaterials03 medical and health sciences0302 clinical medicinelawmedicineRelative humidity030212 general & internal medicineDehydrationSalineSilicone hydrogelDaily wearmedicine.diseaseContact Lenses HydrophilicSurgeryContact lensLens (optics)030221 ophthalmology & optometryGravimetric analysisContact Lens SolutionsBiomedical engineeringJournal of biomedical materials research. Part B, Applied biomaterials
researchProduct

Knowledge and awareness regarding biomedical waste management in dental teaching institutions in India- A systematic review.

2014

Objectives: Proper handling, treatment and disposal of biomedical wastes are important elements in any health care setting. Not much attention has been paid to the management of Biomedical Waste (BMW) in recent years, in dental colleges and hospitals in India. The present systematic review was conducted to assess knowledge and awareness regarding BMW management among staff and students of dental teaching institutions in India. Material and Methods: A systematic review of relevant cross-sectional studies was conducted regarding BMW management in India in dental teaching institutions in India. Six studies were finally included in the present review after conducting both electronic and manual …

medicine.medical_specialtyMedical educationbusiness.industryAwareness levelAlternative medicineMEDLINEBiomedical wasteLegislatureOdontologíaReview:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludCommunity and Preventive DentistryHealth care wasteHazardous wasteHealth careUNESCO::CIENCIAS MÉDICASmedicinebusinessGeneral DentistryJournal of clinical and experimental dentistry
researchProduct

Comprehensive pharmacokinetic model of insulin Glargine and other insulin formulations.

2005

In this paper, a comprehensive pharmacokinetic model for different insulin formulations including insulin Glargine is developed based on the model proposed by Trajanoski et al. (1993). Current models show limitations for insulin Glargine due to the appearance of an uncharacteristic peak in the concentration-time evolution of plasma insulin that does not coincide with real experimental data. This important limitation has been solved in this paper by introducing a new virtual insulin state called the bound state, in addition to the dimeric and hexameric ones. Trying to describe the retarded action of insulin Glargine, the modeling idea behind this approach is that immediately after the subcut…

medicine.medical_specialtyMetabolic Clearance Ratemedicine.medical_treatmentBiomedical EngineeringInsulin GlargineModels BiologicalInsulin Infusion SystemsPharmacokineticsInternal medicinemedicineApplied mathematicsHumansInsulinComputer SimulationSpatial diffusionMathematicsInsulin glargineInsulinDrug Therapy Computer-AssistedInsulin Long-ActingExogenous insulinEndocrinologyLiverPatient behaviorPlasma insulinmedicine.drugIEEE transactions on bio-medical engineering
researchProduct

Mitochondrial dysfunction in cholestatic liver diseases

2011

et al.

medicine.medical_specialtyMitochondrial DNABiliary cirrhosisMitochondrial HepatopathyApoptosisReviewBiologyMitochondrionmedicine.disease_causeGeneral Biochemistry Genetics and Molecular BiologyLiver diseaseCholestasisInternal medicinemedicineHumansBiología y BiomedicinaCholestasisGeneral Immunology and MicrobiologyLiver Diseasesmedicine.diseaseBile acidsCell biologyMitochondriaEndocrinologyMitochondrial biogenesisOxidative stressMitochondrial functionMitochondrial dysfunctionOxidative stressFrontiers in Bioscience (Elite edition) 4: 2233-2252 (2012)
researchProduct

Electrically induced torque decrease reflects more than muscle fatigue

2014

The aim of the study was to compare the fatigue induced by different electrical stimulation (ES) protocols. The triceps surae muscle of 8 healthy subjects was fatigued with 4 protocols (30 Hz-500 μs, 30 Hz-1 ms, 100 Hz-1 ms, and 100 Hz-500 μs), composed of 60 trains (4 s on-6 s off), delivered at an intensity evoking 30% of maximal voluntary contraction (MVC). Fatigue was quantified by ES and MVC torque decreases. The amplitude of the twitch delivered at the intensity and pulse width used in each fatiguing protocol (twitch at Istim ) was analyzed. All parameters decreased significantly after all protocols. The ES torque decrease correlated positively with the twitch decrease elicited at Ist…

medicine.medical_specialtyMuscle fatiguePhysiologyChemistryHealthy subjectsStimulationIntensity (physics)Cellular and Molecular NeurosciencePhysical medicine and rehabilitationVoluntary contractionTriceps surae musclePhysiology (medical)medicineTorqueNeurology (clinical)Biomedical engineeringMuscle & Nerve
researchProduct

3D virtual histopathology of cardiac tissue from Covid-19 patients based on phase-contrast X-ray tomography

2021

eLife 10, e71359 (2021). doi:10.7554/eLife.71359

medicine.medical_specialtyMyocarditisViral MyocarditisQH301-705.5Science030204 cardiovascular system & hematologyStructure tensorGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineArtificial IntelligencemedicineHumansBiology (General)Intussusceptive angiogenesis030304 developmental biologyx-ray tomography0303 health sciencesGeneral Immunology and MicrobiologySARS-CoV-2business.industryGeneral NeuroscienceMyocardiumQRX-rayHeart600General Medicinemedicine.disease3. Good healthCross section (geometry)MyocarditisEpidemiology and Global Healthcardiac tissueMedicineHistopathologyTomographyTomography X-Ray ComputedCovid-19businessddc:600SynchrotronsResearch ArticleHumanBiomedical engineering
researchProduct

Importance of calibration for diameter and area determination by intravascular ultrasound

1996

Intravascular ultrasound (IVUS) permits quantitative assessment of the lumen diameter and area of coronary arteries. The experimental study was performed to evaluate the accuracy of diameter and area measurements.Lumen quantitation (lumen diameter D and cross-sectional area A) in lucite tubes (lumen diameter 2.5 to 5.7 mm, Plexiglas) was performed using a mechanical IVUS system (HP console, 3.5 F catheter, Boston Scientific, 30 MHz). The influence of fluid type (blood, water and saline solution), fluid temperature (20 degrees C/37 degrees C), catheter to catheter variation, gain setting and ultrasound frequency (12, 20 and 30 MHz) was determined. In blood at 20 degrees C there was a constan…

medicine.medical_specialtyObservational errormedicine.diagnostic_testPhantoms Imagingbusiness.industryUltrasoundLumen (anatomy)Coronary VesselsCoronary arteriesCathetermedicine.anatomical_structureCalibrationIntravascular ultrasoundCirculatory systemHumansMedicineRadiology Nuclear Medicine and imagingRadiologyCardiology and Cardiovascular MedicinebusinessUltrasonography InterventionalCardiac imagingBiomedical engineeringThe International Journal of Cardiac Imaging
researchProduct