Search results for "Biomechanical"

showing 10 items of 524 documents

Inclusion of the periodontal ligament in studies on the biomechanical behavior of fiber post-retained restorations: An in vitro study and three-dimen…

2016

Endodontically treated teeth are known to have reduced structural strength. Periodontal ligament may influence fracture resistance. The purpose of this study was to assess the influence of including the periodontal ligament in biomechanical studies about endodontically treated and restored teeth. Forty human maxillary central incisors were treated endodontically and randomly divided into four groups: non-crowned (with and without an artificial ligament) and crowned (with and without an artificial ligament) with glass-ceramic crowns. All groups received prefabricated glass-fiber posts and a composite resin core. Specimens were tested, under a flexural–compressive load, until failure occurre…

Materials sciencePeriodontal Ligamentmedicine.medical_treatmentDental ResearchFinite Element AnalysisDentistryComposite ResinsCrown (dentistry)03 medical and health sciences0302 clinical medicinestomatognathic systemIncisormedicinePeriodontal fiberIn vitro studyHumansMaxillary central incisorRestorative dentistryOrthodonticsTooth Nonvitalbusiness.industryMechanical EngineeringBiomechanics030206 dentistryGeneral MedicineModels DentalBiomechanical PhenomenaIncisorstomatognathic diseasesmedicine.anatomical_structureLigamentbusiness030217 neurology & neurosurgeryProceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
researchProduct

Can biomechanical analysis shed some light on aneurysmal pathophysiology? Preliminary study on ex vivo cerebral arterial walls

2019

Abstract Background The pathophysiology of cerebral aneurysm is complex and poorly understood, and it can have the most catastrophic clinical presentation. Flow dynamics is a key player in the initiation and progression of aneurysm. Better understanding the interaction between hemodynamic loading and biomechanical wall responses can help to add the missing piece on aneurysmal pathophysiology. In this laboratory study we aimed to analyze the effect of the application of a mechanical force to cerebral arterial walls. Methods Displacement control tests were performed on five porcine cerebral arteries. The test machine was the T150 Nanotensile. The stiffness variation with the increment of the …

Materials scienceSwineCerebral arteriesBiophysicsHemodynamicsStrain (injury)Weight-BearingStress (mechanics)03 medical and health sciences0302 clinical medicineAneurysmmedicineAnimalsHumansOrthopedics and Sports MedicineAortaMechanical PhenomenaHemodynamicsStiffnessIntracranial AneurysmArteries030229 sport sciencesmedicine.diseaseBiomechanical analysis Flow dynamics Cerebral aneurysm Cerebral arterial wallsPathophysiologyBiomechanical PhenomenaHyperelastic materialAnisotropyStress Mechanicalmedicine.symptom030217 neurology & neurosurgeryBiomedical engineering
researchProduct

Investigation of the hemodynamic flow conditions and blood-induced stresses inside an abdominal aortic aneurysm by means of a SPH numerical model.

2019

The estimation of blood flow-induced loads occurring on the artery wall is affected by uncertainties hidden in the complex interaction of the pulsatile flow, the mechanical parameters of the artery, and the external support conditions. To circumvent these difficulties, a specific tool is developed by combining the aorta displacements measured by an electrocardiogram-gated-computed tomography angiography, with the blood velocity field computed by a smoothed particle hydrodynamics (SPH) numerical model. In the present work, the SPH model has been specifically adapted to the solution of the 3D Navier-Stokes equations inside a domain with boundaries of prescribed motion. Images of the abdominal…

Materials scienceTime FactorsQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsBiomedical EngineeringPulsatile flowHemodynamicsSettore ICAR/01 - IdraulicaPhysics::Fluid DynamicsAneurysmDiastolemedicine.arterymedicineShear stressPressureHumansComputer SimulationMolecular BiologyAortamedicine.diagnostic_testCardiac cycleApplied MathematicsHemodynamicsModels CardiovascularMechanicsmedicine.diseaseAbdominal aortic aneurysmBiomechanical PhenomenaComputational Theory and MathematicsModeling and SimulationAngiographycardiovascular systemHydrodynamicsStress MechanicalInfrarenal abdominal aorta aneurysm shear stresses arterial wall SPH moving boundarySoftwareAlgorithmsBlood Flow VelocityAortic Aneurysm AbdominalInternational journal for numerical methods in biomedical engineeringREFERENCES
researchProduct

A Standardised Approach to the Biomechanical Evaluation of Tracheal Grafts

2021

[EN] The ideal tracheal substitute must have biomechanical properties comparable to the native trachea, but currently there is no standardised approach to evaluating these properties. Here we propose a novel method for evaluating and comparing the properties of tracheal substitutes, thus systematising both measurement and data curation. This system was tested by comparing native rabbit tracheas to frozen and decellularised specimens and determining the histological characteristics of those specimens. We performed radial compression tests on the anteroposterior tracheal axis and longitudinal axial tensile tests with the specimens anastomosed to the jaw connected to a measuring system. All ca…

Materials scienceVolume UnitBioengineeringtracheaBiochemistryMicrobiologyArticlebiomechanicsUltimate tensile strengthAnimalsHumansTissue engineeringBiomechanicsLongitudinal axisairway bioengineering biomechanics tissue engineering trachea transplantationMolecular BiologyTransplantationbioengineeringTissue ScaffoldsBiomechanicsrespiratory systemQR1-502Biomechanical PhenomenaTracheaTransplantationAirwayRadial compressionairwaytissue engineeringRabbitsBiomedical engineeringtransplantationBiomolecules
researchProduct

Maximum forces acting on the abdominal wall: Experimental validation of a theoretical modeling in a human cadaver study

2011

Incisional hernias following median laparotomy have a high incidence and recurrence rate after repair, so that a better understanding of the linea alba biomechanics is desirable. The mechanical stress exerted on the linea alba in living humans is primarily generated by the musculature. In this human cadaver study, intraabdominal pressure was simulated by insertion of a balloon that was increasingly filled to maximal pressures of 200 mbar. The related forces acting transversely on the linea alba at maximum pressure were found to be between 41.6 and 52.2 N/cm (mean = 45.9 N/cm), which is in agreement with a recent modeling of the related forces.

Materials sciencemedicine.medical_treatmentBiomedical EngineeringBiophysicsValidation Studies as TopicBalloonModels BiologicalAbdominal wallPostoperative ComplicationsCadaverTensile StrengthLaparotomyCadaverPressuremedicineHumansHerniaFasciaLaparotomyAbdominal WallBiomechanicsAnatomymedicine.diseaseBiomechanical PhenomenaFasciotomyHernia Abdominalmedicine.anatomical_structureLinea alba (abdomen)AbdomenMedical Engineering & Physics
researchProduct

Estimation of the elastic parameters of human liver biomechanical models by means of medical images and evolutionary computation.

2013

This paper presents a method to computationally estimate the elastic parameters of two biomechanical models proposed for the human liver. The method is aimed at avoiding the invasive measurement of its mechanical response. The chosen models are a second order Mooney–Rivlin model and an Ogden model. A novel error function, the geometric similarity function (GSF), is formulated using similarity coefficients widely applied in the field of medical imaging (Jaccard coefficient and Hausdorff coefficient). This function is used to compare two 3D images. One of them corresponds to a reference deformation carried out over a finite element (FE) mesh of a human liver from a computer tomography image, …

Mathematical optimizationSimilarity (geometry)Jaccard indexPhysics::Medical PhysicsEvolutionary algorithmHealth InformaticsModels BiologicalEvolutionary computationImaging Three-DimensionalJaccardScatter searchImage Interpretation Computer-AssistedGenetic algorithmHumansBiomechanical modeling Genetic algorithm Hausdorff Jaccard Liver Scatter searchMathematicsFunction (mathematics)Biological EvolutionFinite element methodBiomechanical PhenomenaComputer Science ApplicationsError functionGenetic algorithmLiverHausdorffBiomechanical modelingLENGUAJES Y SISTEMAS INFORMATICOSAlgorithmSoftware
researchProduct

Effect of clenching on biomechanical response of human mandible and temporomandibular joint to traumatic force analyzed by finite element method

2013

Purpose: The purpose of the present study was to analyze the effect of clenching on the biomechanical response of human mandible and temporomandibular joint (TMJ) to traumatic force by the finite element (FE) method. Material and Methods: FE models of the mandible and the TMJ in resting and clenching positions were prepared. Distribution and magnitude of von Mises stress were analyzed by applying force as a point load in the symphyseal, canine, body and angle regions of the mandible. In addition, strain energy density (SED) at the articular disc and in posterior connective tissue of TMJ was analyzed. Results: In the resting position, von Mises stress was mainly concentrated at the condylar …

Models AnatomicMaterials scienceFinite Element AnalysisOdontologíaMandibleCondyleBite ForceStress (mechanics)stomatognathic systemmedicinePressurevon Mises yield criterionHumansGeneral DentistryTemporomandibular JointMandibleStrain energy density functionAnatomy:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludFinite element methodTemporomandibular jointBiomechanical PhenomenaBite force quotientmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryResearch-ArticleOral Surgery
researchProduct

Avoiding tunnel collisions between fibular collateral ligament and ACL posterolateral bundle reconstruction

2010

PURPOSE: The purpose of this study was to evaluate the risk of tunnel collisions of the fibular collateral ligament (FCL) and posterolateral bundle anterior cruciate ligament (PLB-ACL) tunnels during a combined FCL and double-dundle (DB) ACL reconstruction. METHODS: Thirty-six 4th-generation synthetic femurs (Sawbones, Pacific Research Laboratories, Vashon, WA) were utilized, and two different femur sizes were used. A FCL tunnel and a PLB-ACL tunnel were reamed on each femur. The tunnels of synthetic specimens that did not have a collision were filled with an epoxy resin augmented with BaSO(4) and radiographic evaluation, and Multidetector CT exams of the specimens were performed. RESULTS: …

Models Anatomicmedicine.medical_specialtyKnee JointRadiographyAnterior cruciate ligamentSensitivity and SpecificityCondylemedicineSettore MED/33 - Malattie Apparato LocomotoreHumansOrthopedics and Sports MedicineFemurDouble Bundle anterior cruciate ligament reconstruction Multiple ligament reconstruction fibular collateral ligament reconstruction ACL reconstructionFemurAnterior Cruciate LigamentIntraoperative ComplicationsOrthodonticsbusiness.industryFibular collateral ligamentCollateral LigamentsPlastic Surgery ProceduresCombined Modality TherapyBiomechanical Phenomenamedicine.anatomical_structureFibulaCoronal planeOrthopedic surgerySurgeryTomographybusinessTomography X-Ray Computed
researchProduct

Stress distribution of complete-arch implant-supported prostheses reinforced with silica-nylon mesh

2019

Made available in DSpace on 2020-12-12T01:20:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2019-01-01 Background: This study evaluated the presence of a silica-nylon mesh and two cantilever lengths on the biomechanical behavior of complete-arch implant-supported prostheses. Material and Methods: Twenty-four (24) complete mandibular arch implant-supported prostheses were divided into 4 groups according to the presence of reinforcing mesh (with or without) and the cantilever length (molar-15 mm or premolar-5 mm). The specimens were submitted to strain gauge analysis (30-kgf, 10 s) at different points (molar and premolar). Three-dimensional models were created based on the in vitro spec…

MolarCantileverMaterials sciencemedicine.medical_treatmentProsthesisStress (mechanics)03 medical and health sciences0302 clinical medicinestomatognathic systemmedicinePremolarGeneral DentistryStrain gaugeStress concentrationOrthodonticsResearchDental implantsFinite element analysis030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Finite element methodProsthetic dentistrymedicine.anatomical_structureUNESCO::CIENCIAS MÉDICASBiomechanical response030217 neurology & neurosurgeryJournal of Clinical and Experimental Dentistry
researchProduct

Chemistry Explained by Topology: An Alternative Approach

2011

Molecular topology can be considered an application of graph theory in which the molecular structure is characterized through a set of graph-theoretical descriptors called topological indices. Molecular topology has found applications in many different fields, particularly in biology, chemistry, and pharmacology. The first topological index was introduced by H. Wiener in 1947 [1]. Although its very first application was the prediction of the boiling points of the alkanes, the Wiener index has demonstrated since then a predictive capability far beyond that. Along with the Wiener index, in this paper we focus on a few pioneering topological indices, just to illustrate the connection between p…

Molecular StructureChemistry PhysicalChemistryOrganic ChemistryGraph theoryGeneral MedicineWiener indexBiologyTopologyBiomechanical PhenomenaComputer Science ApplicationsConnection (mathematics)Set (abstract data type)Structure-Activity RelationshipModels ChemicalTopological indexAlkanesDrug DiscoveryQuantum TheoryChemistry (relationship)Focus (optics)Topology (chemistry)Combinatorial Chemistry & High Throughput Screening
researchProduct