Search results for "Biomedical engineering"

showing 10 items of 2020 documents

Rechnerunterstützte Auswertung elektromyographischer und goniometrischer Meßsignale mit statistischen Signalanalyseverfahren

1998

Signal processingmedicine.diagnostic_testComputer scienceGoniometerBiomedical EngineeringmedicineElectromyographySignalBiomedical engineeringBiomedizinische Technik/Biomedical Engineering
researchProduct

Quantification of synchronization during atrial fibrillation by Shannon entropy: Validation in patients and computer model of atrial arrhythmias

2005

Atrial fibrillation (AF), a cardiac arrhythmia classically described as completely desynchronized, is now known to show a certain amount of synchronized electrical activity. In the present work a new method for quantifying the level of synchronization of the electrical activity recorded in pairs of atrial sites during atrial fibrillation is presented. A synchronization index (Sy) was defined by quantifying the degree of complexity of the distribution of the time delays between sites by Shannon entropy estimation. The capability of Sy to discriminate different AF types in patients was assessed on a database of 60 pairs of endocardial recordings from a multipolar basket catheter. The analysis…

Signal processingmedicine.medical_specialtyTime delaysPhysiologyEntropyBiomedical EngineeringBiophysicsSensitivity and SpecificitySynchronizationHeart Conduction SystemArrhythmia (mechanisms)Internal medicinePhysiology (medical)medicineHumansIn patientDiagnosis Computer-AssistedMathematicsBody Surface Potential MappingModels CardiovascularCardiac arrhythmiaReproducibility of ResultsAtrial fibrillationAtrial arrhythmiasComputer simulationmedicine.diseaseAtrial fibrillationElectrophysiologyElectrophysiologymedicine.anatomical_structureBiophysicCardiologyRight atriumAlgorithms
researchProduct

Postprocessing algorithm for automated analysis of pelvic intraoperative neuromonitoring signals

2016

Abstract Two dimensional pelvic intraoperative neuromonitoring (pIONM®) is based on electric stimulation of autonomic nerves under observation of electromyography of internal anal sphincter (IAS) and manometry of urinary bladder. The method provides nerve identification and verification of its’ functional integrity. Currently pIONM® is gaining increased attention in times where preservation of function is becoming more and more important. Ongoing technical and methodological developments in experimental and clinical settings require further analysis of the obtained signals. This work describes a postprocessing algorithm for pIONM® signals, developed for automated analysis of huge amount of …

Signal processingpostprocessing algorithmbusiness.industryRBiomedical Engineeringpelvic intraoperative neuromonitoringsignal analysis03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisMedicineMedicine030211 gastroenterology & hepatologyComputer visionArtificial intelligencebusinessCurrent Directions in Biomedical Engineering
researchProduct

Qualitative and quantitative characterization of the in vitro dehydration process of hydrogel contact lenses

2007

Purpose: To investigate the in vitro dehydration process of conventional hydrogel and silicone-hydrogel contact lens materials. Methods: Eight conventional hydrogel and five silicone-hydrogel contact lenses were dehydrated under controlled environmental conditions on an analytical balance. Data were taken at 1-min intervals and dehydration curves of cumulative dehydration (CD), valid dehydration (VD), and dehydration rate (DR) were obtained. Several quantitative descriptors of the dehydration process were obtained by further processing of the information. Results: Duration of phase I (r 2 5 0.921), CD at end of phase I (r 2 5 0.971), time to achieve a DR of � 1%/min (r 2 5 0.946) were stron…

SiliconBiomedical EngineeringAnalytical chemistry02 engineering and technologygravimetryGravimetric methodBiomaterials03 medical and health sciences0302 clinical medicinesilicone-hydrogelPhase (matter)medicineDehydrationPolymerWater contentHydrogel dehydrationChromatographyScience & TechnologyDehydrationChemistryHydrogelsdehydrationContact lens021001 nanoscience & nanotechnologymedicine.diseaseContact Lenses HydrophilicWater retentionContact lenscontact lensesSelf-healing hydrogels030221 ophthalmology & optometryGravimetric analysisMethacrylatesmedicine.symptomNegative correlationhydrogel0210 nano-technologyhydration
researchProduct

Optical tweezing using tunable optical lattices along a few-mode silicon waveguide

2018

International audience; Fourteen years ago, optical lattices and holographic tweezers were considered as a revolution, allowing for trapping andmanipulating multiple particles at the same time using laser light. Since then, near-field optical forces have arousedtremendous interest as they enable efficient trapping of a wide range of objects, from living cells to atoms, in integrateddevices. Yet, handling at will multiple objects using a guided light beam remains a challenging task for current on-chipoptical trapping techniques. We demonstrate here on-chip optical trapping of dielectric microbeads and bacteria usingone-dimensional optical lattices created by near-field mode beating along a f…

SiliconMaterials scienceOptical TweezersSiliconBiomedical EngineeringNanophotonicsHolographychemistry.chemical_elementPhysics::OpticsBioengineering02 engineering and technologyTrappingModels Biological01 natural sciencesBiochemistryWaveguide (optics)law.invention010309 opticslawLab-On-A-Chip Devices0103 physical sciencesTweezersLight beamParticle Sizebusiness.industryGeneral Chemistry021001 nanoscience & nanotechnologyMicrospheres[SPI.ELEC]Engineering Sciences [physics]/ElectromagnetismchemistryOptical tweezers[SPI.OPTI]Engineering Sciences [physics]/Optics / PhotonicNanoparticlesOptoelectronics0210 nano-technologybusiness
researchProduct

Neural cell pattern formation on glass and oxidized silicon surfaces modified with poly(N-isopropylacrylamide)

1996

Control over the adsorption of proteins and over the adsorption and spatial orientation of mammalian cells onto surfaces has been achieved by modification of glass and other silicon oxide substrates with poly(N-isopropylacrylamide) (PNIPAM). The functionalization of the substrates was achieved either by a polymer-analogous reaction of aminosilanes with reactive N-(isopropylacrylamide) (NIPAM)-copolymers and by copolymerization of NIPAM with surface-bound methacrylsilane. The obtained coatings were characterized by FT-1R, ellipsometry, and surface plasmon resonance measurements. The adsorption of two proteins-fibrinogen and ribonuclease A-on these surfaces was studied in situ by real time su…

SiliconMaterials scienceSiliconCell SurvivalPolymersSurface PropertiesUltraviolet RaysBiomedical EngineeringBiophysicschemistry.chemical_elementBioengineeringBiocompatible MaterialsBiomaterialschemistry.chemical_compoundNeuroblastomaAdsorptionSpectroscopy Fourier Transform InfraredCell AdhesionTumor Cells CulturedOrganic chemistryHumansSurface plasmon resonanceSilicon oxideAcrylamidesAdhesionBlood ProteinsGliomaMolecular WeightchemistryChemical engineeringPoly(N-isopropylacrylamide)Surface modificationGlassOxidation-ReductionCell DivisionProtein adsorption
researchProduct

Porous silicon based photoluminescence immunosensor for rapid and highly-sensitive detection of Ochratoxin A.

2017

A rapid and low cost photoluminescence (PL) immunosensor for the determination of low concentrations of Ochratoxin A (OTA) has been developed. This immunosensor was based on porous silicon (PSi) and modified by antibodies against OTA (anti-OTA). PSi layer was fabricated by metal-assisted chemical etching (MACE) procedure. Main structural parameters (pore size, layer thickness, morphology and nanograins size) and composition of PSi were investigated by means of X-Ray diffraction (XRD), scanning electron microscopy (SEM) and Raman spectroscopy. PL-spectroscopy of PSi was performed at room temperature and showed a wide emission band centered at 680 ± 20nm. Protein A was covalently immobilized …

SiliconPhotoluminescenceMaterials scienceScanning electron microscopeBiomedical EngineeringBiophysicsAnalytical chemistryFood Contamination02 engineering and technologyBiosensing TechniquesPorous silicon01 natural sciencesAntibodiessymbols.namesakeElectrochemistryHumansDetection limitImmunoassayQuenching (fluorescence)010401 analytical chemistryGeneral Medicine021001 nanoscience & nanotechnologyIsotropic etchingOchratoxins0104 chemical sciencesGibbs free energysymbols0210 nano-technologyRaman spectroscopyPorosityBiotechnologyBiosensorsbioelectronics
researchProduct

Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses

2008

Abstract: Purpose. To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM). Methods. The topography of five different CL materials was evaluated withAFM over a surface of 25 lm2 according to previously published experimental setup. Average roughness (Ra) and root mean square (Rms) values were obtained for unworn and worn samples. Results. The Ra value increased for balafilcon A (11.62–13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67–15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08–8.42 nm for unworn and worn samples, respectively), g…

SiliconSurface characterizationwearMaterials scienceContact LensesSurface PropertiesSiliconesBiomedical Engineering02 engineering and technologySurface finishMicroscopy Atomic ForceHydrogel Polyethylene Glycol DimethacrylateBiomaterialsAtomic force microscopyPolymer deterioration03 medical and health sciences0302 clinical medicineOpticsMaterials TestingMicroscopySurface roughnessComposite materialdegradationScience & TechnologyAtomic force microscopybusiness.industryHydrogelsLotrafilcon BContact lensSilicone hydrogelContact Lenses Hydrophilic021001 nanoscience & nanotechnologyContact lensPseudomonas aeruginosaWettability030221 ophthalmology & optometryWetting0210 nano-technologybusinessJournal of Biomedical Materials Research Part B: Applied Biomaterials
researchProduct

Ultrasensitive Silicon Nanowire for Real-World Gas Sensing: Noninvasive Diagnosis of Cancer from Breath Volatolome

2014

We report on an ultrasensitive, molecularly modified silicon nanowire field effect transistor that brings together the lock-and-key and cross-reactive sensing worlds for the diagnosis of (gastric) cancer from exhaled volatolome. The sensor is able to selectively detect volatile organic compounds (VOCs) that are linked with gastric cancer conditions in exhaled breath and to discriminate them from environmental VOCs that exist in exhaled breath samples but do not relate to the gastric cancer per se. Using breath samples collected from actual patients with gastric cancer and from volunteers who do not have cancer, blind analysis validated the ability of the reported sensor to discriminate betw…

SiliconVolatile Organic CompoundsMaterials scienceNanowiresMechanical Engineeringdigestive oral and skin physiologyCancerBioengineeringNanotechnologyGeneral ChemistryCondensed Matter Physicsmedicine.diseaseBreath TestsLimit of DetectionNeoplasmsmedicineHumansGeneral Materials ScienceSilicon nanowiresBiomedical engineeringNano Letters
researchProduct

An enhanced random walk algorithm for delineation of head and neck cancers in PET studies

2017

An algorithm for delineating complex head and neck cancers in positron emission tomography (PET) images is presented in this article. An enhanced random walk (RW) algorithm with automatic seed detection is proposed and used to make the segmentation process feasible in the event of inhomogeneous lesions with bifurcations. In addition, an adaptive probability threshold and a k-means based clustering technique have been integrated in the proposed enhanced RW algorithm. The new threshold is capable of following the intensity changes between adjacent slices along the whole cancer volume, leading to an operator-independent algorithm. Validation experiments were first conducted on phantom studies:…

Similarity (geometry)Computer sciencePET imagingBiomedical EngineeringRandom walk030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineImage Processing Computer-AssistedHumansSegmentationComputer visionCluster analysisEvent (probability theory)Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionimedicine.diagnostic_testbusiness.industryPhantoms ImagingBiological target volume; Head and neck cancer segmentation; PET imaging; Random walksComputer Science ApplicationPattern recognitionRandom walkComputer Science ApplicationsBiological target volumeHausdorff distancePositron emission tomographyHead and Neck Neoplasms030220 oncology & carcinogenesisPositron-Emission TomographyArtificial intelligenceHead and neck cancer segmentationComputer Vision and Pattern RecognitionbusinessAlgorithmsBiological target volume Head and neck cancer segmentation PET imaging Random walks Algorithms Head and Neck Neoplasms Humans Image Processing Computer-Assisted Phantoms Imaging Positron-Emission TomographyVolume (compression)
researchProduct