Search results for "Biomedical engineering"
showing 10 items of 2020 documents
Substantial Reduction of Platelet Adhesion by Heparin-Coated Stents
2001
Although optimized antiplatelet medication has improved the clinical outcome after coronary stenting, vessel occlusion and restenosis still remain a relevant clinical problem. Platelets play a key role in this process. Therefore, the authors compared the platelet adhesion on different stent surface modifications (electropolished without coating or coated with carbon, carbon and additional heparin, silicon carbide, or heparin alone) to investigate their role in reducing platelet adhesion. All stents and additional stainless steel plates were incubated in heparinized whole blood with radiolabeled platelets. After washing the stents and plates four times, radioactivity caused by the adhesion o…
Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: A comparison of six diffe…
2012
Abstract Background An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. Methods New Zealand white rabbits were used for this study. Two meshes of the same brand (Ethicon Physiomesh™, Bard Composix ® L/P, Gore Dualmesh ® , Bard Sepramesh ® , Ethicon Proceed ® or Parietex™ Composite) were implanted into each animal for assessment of intra-abdominal hernia repair, with a total of ten meshes per group. Twelve weeks after implantation, the abdominal …
Modern Strategies in the Prevention of Implant-Associated Infections
2005
The application of medical devices either for temporary or permanent use has become an indispensible part of almost all fields of medicine. However, foreign bodies are associated with a substantial risk of bacterial and fungal infections. Implant-associated infections significantly contribute to the still increasing problem of nosocomial infections. To reduce the incidence of such infections, specific guidelines providing evidence-based recommendations and comprising both technological and nontechnological strategies for prevention have been established. Strict adherence to hygienic rules during insertion or implantation of the device are aspects of particular importance. Besides such basi…
Medicated hydrogels of hyaluronic acid derivatives for use in orthopedic field.
2013
Physical hydrogels have been obtained from hyaluronic acid derivatized with polylactic acid in the presence or in the absence of polyethylene glycol chains. They have been extemporarily loaded with antibacterial agents, such as vancomycin and tobramycin. These medicated hydrogels have been used to coat titanium disks (chosen as simple model of orthopedic prosthesis) and in vitro studies in simulated physiological fluid have been performed as a function of time and for different drug loading and polymer concentration values. Sterilization process performed on the hydrogels does not change their rheological behavior and release properties as well as the chemical structure of starting copolyme…
Molecular genetics of Staphylococcus epidermidis biofilms on indwelling medical devices.
2005
Staphylococcus epidermidis is an opportunistic pathogen associated with foreign body infections and nosocomial sepsis. The pathogenicity of S. epidermidis is mostly due to its ability to colonize indwelling polymeric devices and form a thick, multilayered biofilm. Biofilm formation is a major problem in treating S. epidermidis infection as biofilms provide significant resistance to antibiotics and to components of the innate host defenses. Various cell surface associated bacterial factors play a role in adherence and accumulation of the biofilm such as the polysaccharide intercellular adhesin and the autolysin AtlE. Furthermore, recent studies have shown that global regulators such as the …
Pitfalls in whole body MRI with diffusion weighted imaging performed on patients with lymphoma: What radiologists should know
2016
The technological advances in radiological imaging and the relevance of a diagnostic tool that may reduce radiation-induced long-term effects have led to a widespread use of whole body magnetic resonance imaging (WB-MRI) with diffusion weighted imaging for oncologic patients. A lot of studies demonstrated the feasibility and reliability of WB-MRI as an alternative technique for lymphoma staging and response assessment during and after treatment. In this paper, taking advantage of our 2years of experience using WB-MRI for lymphoma, we discuss the main pitfalls and artifacts radiologists should know examining a WB-MRI performed on this typology of patients in order to avoid images misinterpre…
Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children
2018
Purpose: The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL) thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate their variation according to axial length (AL) and spherical equivalent (SE) in healthy children. Methods: This study included 293 pairs of eyes of 293 children (145 boys and 148 girls), ranging in age from 6 to 17 years. Subjects were divided according to SE in control (emmetropia, 99 children), myopia (100 children) and hyperopia (94 children) groups and according to axial AL in 68 short ([Formula: see text]22.00[Formula: see text]mm, 68), medium (from [For…
Safety and Efficacy of Ranibizumab in Macular Edema following Retinal Vein Occlusion.
2013
Macular edema is the leading cause of visual impairment in patients with retinal vein occlusion. Limited improvements may be obtained with laser photocoagulation or intravitreal triamcinolone. However, according to the data provided by randomized clinical trials, intravitreal injections of ranibizumab (Lucentis; Genentech, South San Francisco, CA) constitute a new effective and safe option for the management of these vision-threatening diseases. The aim of the present review is to summarize the clinical evidence of ranibizumab for macular edema due to retinal vein occlusions.
Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system
2016
Background: The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Material and Methods: Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the …
BENEFICIAL EFFECT OF PROBIOTICS ADMINISTRATION IN INFLAMMATORY BOWEL DISEASE AND RELATED SPONDYLOARTHROPATHY: A PROSPECTIVE STUDY
2015
Background: Therapeutic treatment for inflammatory bowel disease (IBD) may follow different approaches, systemic as well as local, especially when the target is the osteoarticular apparatus. Although some clinical trials have suggested benefits from probiotics administration in IBD, there is still a great deal of controversy on their use. The aim of this study was to further investigate the effects of probiotics in patients with IBD and related spondyloarthropathy. Material/Methods: Fifty-nine patients affected by IBD with extra-intestinal involvement where evaluated from 2006 to 2010. Twenty-eight patients received administration of a standard therapy with mesalazine and 31 where treated w…