Effect of chronic unloading and rehabilitation on human Achilles tendon properties: a velocity-encoded phase-contrast MRI study

2008

The objective of this study was to measure and monitor changes in Achilles tendon mechanical properties and force production capability of triceps surae muscles after 4 wk of limb suspension and 6 wk of physical rehabilitation. Five healthy volunteers underwent unilateral lower limb suspension followed by weekly physiotherapy. A velocity-encoded, phase-contrast magnetic resonance imaging (VE-PC-MRI) technique was used to estimate the tendon strain as a function of force produced during the submaximal isometric contractions. After limb suspension, triceps surae muscle strength decreased to 53.2 ± 15.6% (mean ± SD) of the presuspension level ( P < 0.05). Young's modulus, estimated from the…

AdultMaleMuscle Strength DynamometerTime FactorsPhysiologymedicine.medical_treatmentPhase contrast microscopyTreatment outcomeIsometric exerciseMuscle Strength DynamometerAchilles Tendonlaw.inventionlawPhysiology (medical)Isometric ContractionmedicineHumansMuscle StrengthMuscle SkeletalPhysical Therapy ModalitiesWeightlessness SimulationAchilles tendonRehabilitationmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingAnatomyArticlesRecovery of Functionmusculoskeletal systemMagnetic Resonance ImagingElasticityTendonMuscular Atrophymedicine.anatomical_structureTreatment OutcomeFemaleStress MechanicalbusinessBiomedical engineering
researchProduct

Entrapment of adult fingers between window glass and seal entry of a motor vehicle side door: an experimental study for investigation of the force at…

2011

In modern motor vehicles with automatic power windows, a potential hazard exists for jam events of fingers between the window glass and seal entry. This study determined entrapment forces acting on adult fingers at the subjective maximum pain threshold during entrapment in such windows. The length and the girth of the proximal and distal interphalangeal joints of the triphalangeal fingers of the right hands of 109 participants (60 men, 49 women) were measured; the diameter was calculated from girth, which was assumed to be circular. The automatic power window system of a motor vehicle side door was changed to a mechanical system. During entrapment the force distributed across the four proxi…

AdultMalePain ThresholdAdolescentMovementBiomedical EngineeringBiophysicsPoison controlSeal (mechanical)Girth (geometry)FingersEntrapmentYoung AdultFinger JointThreshold of painmedicineHumansOrthopedics and Sports MedicineMathematicsOrthodonticsbusiness.industryRehabilitationWindow (computing)Index fingerStructural engineeringMiddle AgedBiomechanical PhenomenaMotor Vehiclesmedicine.anatomical_structureFemaleGlassSafetyInterphalangeal JointbusinessJournal of biomechanics
researchProduct

Spatial discrimination thresholds for pain and touch in human hairy skin

2001

The traditional concept that pain is poorly localized has been challenged by recent studies, where subjects were able to point to the stimulated spot on the skin with an accuracy of 10-20 mm. Pointing movements themselves, however, have errors of about 15 mm. To determine the limits of sensory performance of the nociceptive system independent of motor performance, point localization of heat pain (540 mJ punctate laser stimuli, 5 mm diameter), mechanical pain (256 mN punctate probe, 200 microm diameter), and touch (16 mN von Frey probe, 1.1 mm diameter) were tested in a two-alternative forced-choice paradigm in 12 healthy subjects. Stimuli were applied in randomized order to two parallel lin…

AdultMalePain Thresholdmedicine.medical_specialtyHot TemperatureSpatial discriminationSensory systemParallelAngioplasty LaserDiscrimination PsychologicalPhysical StimulationmedicineNoxious stimulusHumansSkinPhysicsHairy skinMiddle AgedHandSurgeryAnesthesiology and Pain MedicineNociceptionNeurologyTouchReceptive fieldVon freyFemaleNeurology (clinical)HairBiomedical engineeringPain
researchProduct

Effects of prefabricated and custom-made foot orthoses on skin temperature of the foot soles after running

2019

OBJECTIVE Foot orthoses are increasingly used by runners despite the controversy about whether their use can reduce the risk of overuse injuries. Some authors have found modifications in plantar pressures with the use of foot orthoses, which could produce changes in the surface skin temperature of the foot soles. The aim of this study was to analyse the effects of custom-made and prefabricated foot orthoses on the skin temperature of different regions of both foot soles after running. APPROACH Twenty-four participants carried out a maximal aerobic speed test as a pre-test, and three running tests at the laboratory wearing different foot orthoses conditions (control, prefabricated and custom…

AdultMalePhysiology0206 medical engineeringBiomedical EngineeringBiophysicsFoot Orthoses02 engineering and technologyRunning03 medical and health sciences0302 clinical medicineFoot solesPhysiology (medical)HumansMedicineFoot OrthosesOrthodonticsFootbusiness.industrySpeed testForefootSkin temperature020601 biomedical engineeringFemaleSkin Temperaturebusiness030217 neurology & neurosurgeryPhysiological Measurement
researchProduct

Categorizing the Role of Respiration in Cardiovascular and Cerebrovascular Variability Interactions

2022

Objective: Respiration disturbs cardiovascular and cerebrovascular controls but its role is not fully elucidated. Methods: Respiration can be classified as a confounder if its observation reduces the strength of the causal relationship from source to target. Respiration is a suppressor if the opposite situation holds. We prove that a confounding/suppression (C/S) test can be accomplished by evaluating the sign of net redundancy/synergy balance in the predictability framework based on multivariate autoregressive modelling. In addition, we suggest that, under the hypothesis of Gaussian processes, the C/S test can be given in the transfer entropy decomposition framework as well. Experimental p…

AdultMalePhysiologyBiomedical EngineeringsynergyBlood Pressurecardiac neural controlYoung Adulthead-up tiltHeart RateHumansArterial PressureAnesthesiaPropofolAgedMultivariate autoregressive modelredundancyRespirationcerebrovascular autoregulationautonomic nervous systemheart rate variabilityMediationtransfer entropyHeartIndexesMiddle Agedsuppressiongeneral anesthesiapredictability decompositionconfoundingCerebrovascular CirculationSettore ING-INF/06 - Bioingegneria Elettronica e Informaticaautonomic nervous system; cardiac neural control; cerebrovascular autoregulation; confounding; general anesthesia; head-up tilt; heart rate variability; Multivariate autoregressive model; predictability decomposition; redundancy; suppression; synergy; transfer entropy;ProtocolsRegulation
researchProduct

Potentiation of the mechanical behavior of the human skeletal muscle through prestretching

1979

Force-velocity and power-velocity curves in a vertical jump involving movements around several joints were derived from vertical ground reaction forces and knee angular velocities. The jumps were performed with weights from 10 to 160 kg added on the shoulders. The obtained curves from a semi-squatting static starting position resembled those reported for isolated muscles or single muscle groups. Vertical jumps were also performed in the conditions where the shortening of the leg extensors was preceded by prestretching of the active muscles either through a preparatory counter-movement or dropping down on the force-platform from the various heights ranging from 20 to 100 cm. Prestretching mo…

AdultMalePhysiologyChemistryMusclesElastic energySkeletal muscleLong-term potentiationMuscle activationAnatomyElasticityVertical jumpmedicine.anatomical_structureReflexmedicineHumansGround reaction forceMechanical energyBiomedical engineeringActa Physiologica Scandinavica
researchProduct

The effect of pre-stretch on mechanical efficiency of human skeletal muscle

1987

The mechanical efficiency of positive work was studied in six subjects performing three different types of exercises. On the first occasion the subjects ran on a motor-driven treadmill at 3.33 m s-1; the second and the third exercises consisted of performing rhythmical vertical jumps for 1 min both in rebound (RJ) and no-rebound (NRJ) conditions. The mechanical efficiency calculated in NRJ, which reflects only the conversion of biochemical energy into mechanical work, was found to be lower than the corresponding observation in RJ, 17.2 vs. 27.8% (P less than 0.001), respectively. These differences could not be explained by only the storage and recoil of elastic energy occurring in RJ compar…

AdultMalePhysiologyChemistryPhysical ExertionWork (physics)Elastic energySkeletal muscleAnatomymedicine.disease_causeElasticityStretch shortening cycleRunningPre stretchJumpingmedicine.anatomical_structuremedicineJumpHumansTreadmillMechanoreceptorsMuscle ContractionBiomedical engineeringActa Physiologica Scandinavica
researchProduct

Effect of electrode location on surface electromyography changes due to eccentric elbow flexor exercise.

2009

Experiments were carried out to determine whether the location of electrodes has an effect on eccentric exercise–induced changes in surface electromyography (sEMG) variables in the biceps brachii muscle. sEMG signals were recorded with a grid of 64 electrodes before and up to 4 days post-exercise. Root mean square (RMS) and mean power frequency (MNF) were calculated for: (1) each channel; (2) as an average of all channels; and (3) as an average of individual channel rows and columns. Mean muscle-fiber conduction velocity (CV) was estimated similarly but was based on double-differential channels. Maximal isometric voluntary torque decreased 21.3 ± 5.6% post-exercise. The average sEMG variabl…

AdultMalePhysiologyMuscle Fibers SkeletalPainElectromyographyIsometric exerciseNerve conduction velocityRoot mean squareCellular and Molecular NeurosciencePhysiology (medical)Isometric ContractionmedicineElbowEccentricHumansMuscle SkeletalElectrodesExerciseMathematicsMuscle fatiguemedicine.diagnostic_testBiceps brachii muscleElectromyographySignal Processing Computer-AssistedAnatomyElectrode locationNeurology (clinical)Biomedical engineeringMuscle ContractionMusclenerve
researchProduct

Influence of dental occlusion conditions on plantar pressure distribution during standing and walking – A gender perspective

2021

Abstract The aim of this study was to investigate gender-specific influences of different symmetric and asymmetric occlusion conditions on postural control during standing and walking. The study involved 59 healthy adult volunteers (41 f/19 m) aged between 22 and 53 years (30.2 ± 6.3 years). Postural control measurements were carried out using a pressure plate by measuring plantar pressure distribution during standing and walking test conditions. Seven different occlusion conditions were tested. Prior to a MANOVA model analysis, the relationship between the two test conditions were checked using a factor analysis with a varying number of factors (between 2 and 10). The plantar pressure dist…

AdultMalePressure plateCoefficient of variation0206 medical engineeringBiomedical EngineeringBiophysicsWalking02 engineering and technologyPostural controlDental OcclusionYoung Adult03 medical and health sciences0302 clinical medicineMultivariate analysis of varianceOcclusionPressureHumansMedicinePostural BalanceOrthodonticsFootbusiness.industryDental occlusionPlantar pressureMiddle Aged020601 biomedical engineeringSplintsFemalebusiness030217 neurology & neurosurgeryMedical Engineering & Physics
researchProduct

Non-contact breath sampling for sensor-based breath analysis

2019

Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a…

AdultMalePulmonary and Respiratory MedicineSpectrum analyzer:MEDICINE [Research Subject Categories]breath samplingDiaphragmatic breathingContext (language use)01 natural sciencesYoung Adult03 medical and health sciences0302 clinical medicinevolatile organic compoundsHumansbreath analysisVolatile Organic CompoundsRespiration010401 analytical chemistryBreath samplingExhalationSampling (statistics)Middle AgedPTR-MS0104 chemical sciencesBreath Tests030228 respiratory systemBreath gas analysisBreathingEnvironmental scienceFemaleBiomedical engineeringJournal of Breath Research
researchProduct