Search results for "Biomedical engineering"
showing 10 items of 2020 documents
Functional assessment of the quality of human hepatocyte preparations for cell transplantation.
2008
Hepatocyte transplantation is an alternative therapy to orthotopic liver transplantation for the treatment of liver diseases. Good quality freshly isolated or cryopreserved human hepatocytes are needed for clinical transplantation. However, isolation, cryopreservation, and thawing processes can seriously impair hepatocyte viability and functionality. The aim of the present study was to develop a fast and sensitive procedure to estimate the quality of hepatocyte preparations prior to clinical cell infusion. To this end, cell viability, attachment efficiency, and metabolic competence (urea synthesis and drug-metabolizing P450 activities) were selected as objective criteria. Viability of hepat…
Neural and mechanical responses of the triceps surae muscle group after 1 h of repeated fast passive stretches
2004
Experiments were carried out to examine interaction between mechanical changes of the muscletendon unit and reduced reflex sensitivity after repeated and prolonged passive muscle stretching (RPS). There is some evidence that this interaction might be relevant also during active stretch-shortening cycle type of fatigue tasks. The results demonstrated a clear deterioration of voluntarily and electrically induced muscle contractions after RPS. Maximal voluntary contraction (MVC), average electromyographic activities of the gastrocnemius and soleus muscles, and maximal twitch contraction decreased on average by 13.8, 10.4, 7.6, and 16.8%, respectively. In addition, there was a 14% lengthening …
Stretch-reflex mechanical response to varying types of previous muscle activities
2002
This study was designed to examine the effects of varying types of background muscle activity on the stretch-reflex mechanical response. A rapid stretch was applied to the calf muscles after an isometric (pre-ISO), shortening (pre-SHO) and lengthening contraction (pre-LEN) with several pre-contraction levels, respectively. The stretch perturbation was applied with the tibio-tarsal joint angle at 90 degrees. The ankle joint torque elicited by the stretch showed a first peak (non-reflex torque: NRT), a transient drop and a second peak (reflex torque: RT). The muscle activities before the stretch clearly influenced the stretch-reflex mechanical response. The NRT reached the largest peak with t…
Short-latency stretch reflex modulation in response to varying soleus muscle activities.
2002
The current investigation examined the effect of various types of background muscle contractions on the short-latency stretch reflex (SLR) elicited from the soleus muscle while subjects were in a sitting position. A stretch was applied to the calf muscles while they performed an isometric (pre-ISO), shortening (pre-SHO) and lengthening contraction (pre-LEN) with several pre-contraction levels. The ankle was at a 90 degrees tibio-tarsal joint angle when the perturbation was applied. Subjects developed and maintained a given pre-load level, which was maintained at various percentages of the maximum voluntary isometric plantar flexion torque. This was performed at 80 degrees in pre-SHO, 90 deg…
3D-printing-assisted fabrication of chitosan scaffolds from different sources and cross-linkers for dental tissue engineering
2021
The aim of the present study was to fabricate and characterise chitosan scaffolds from animal and fungal sources, with or without gelatine as a co-polymer, and cross-linked to 3-glycidyloxyproply trimethoxysilane (GPTMS) or genipin for application in dental root tissue engineering. Chitosan-based scaffolds were prepared by the emulsion freeze-drying technique. Scanning electron microscopy (SEM) and nano-focus computed tomography (nano-CT) were used to characterise scaffold microstructure. Chemical composition and cross-linking were evaluated by Fourier transform infrared-attenuated total reflectance spectroscopy. Compression tests were performed to evaluate scaffold mechanical properties. S…
Autologous Iliac Bone Graft Compared with Biphasic Hydroxyapatite and Calcium Sulfate Cement for the Treatment of Bone Defects in Tibial Plateau Frac…
2019
Background Bone-graft substitutes are commonly used for the augmentation of traumatic bone defects in tibial plateau fractures. However, their clinical performance compared with that of autologous bone-grafting, the gold standard in bone defect reconstruction, still remains under debate. This study investigates the differences in quality of life, pain, and radiographic outcomes in the treatment of tibial plateau fracture-associated bone defects with either autologous bone grafts or a bioresorbable hydroxyapatite and calcium sulfate cement (CERAMENT BONE VOID FILLER [CBVF]; BONESUPPORT). Methods In this study, 135 patients with acute depression and split-depression fractures of the proximal …
Ultrastructural study by backscattered electron imaging and elemental microanalysis of biomaterial-to-bone interface and mineral degradation of bovin…
2012
Objectives The aim of this study was to perform an ultrastructural study of the bone-to-biomaterial interface and biomaterial mineral degradation in retrieved bone biopsies following maxillary sinus augmentation using bovine xenografts (Endobon®) in 15 clinical cases. Materials and methods Nine months after sinus lifting, bone cores were harvested from the maxillary sinus. The specimens were processed for observation under a scanning electron microscope with backscattered electron imaging (SEM-BSE). In addition, chemical analysis and elemental mapping of the mineral composition were generated using a microanalytical system based on energy-dispersive X-ray spectrometry (EDX). Results No clin…
Force-, EMG-, and elasticity-velocity relationships at submaximal, maximal and supramaximal running speeds in sprinters.
1986
The relationships between ground reaction forces, electromyographic activity (EMG), elasticity and running velocity were investigated at five speeds from submaximal to supramaximal levels in 11 male and 8 female sprinters. Supramaximal running was performed by a towing system. Reaction forces were measured on a force platform. EMGs were recorded telemetrically with surface electrodes from the vastus lateralis and gastrocnemius muscles, and elasticity of the contact leg was evaluated with spring constant values measured by film analysis. Data showed increases in most of the parameters studied with increasing running speed. At supramaximal velocity (10.36 +/- 0.31 m X s-1; 108.4 +/- 3.8%) the…
Do Stretch Durations Affect Muscle Mechanical and Neurophysiological Properties?
2016
International audience; The aim of the study was to determine whether stretching durations influence acute changes of mechanical and neurophysiological properties of plantar flexor muscles. Plantar flexors of 10 active males were stretched in passive conditions on an isokinetic dynamometer. Different durations of static stretching were tested in 5 randomly ordered experimental trials (1, 2, 3, 4 and 10×30-s). Fascicle stiffness index, evoked contractile properties and spinal excitability (Hmax/Mmax) were examined before (PRE), immediately after (POST0) and 5 min after (POST5) stretching. No stretch duration effect was recorded for any variable. Moreover, whatever the stretching duration, st…
Electromechanical delay in skeletal muscle under normal movement conditions.
1979
Electromechanical delays (EMD), the time from onset of EMG activity to change in acceleration or deceleration of the forearm, were studied in concentric and eccentric contractions of biceps and triceps brachii muscles. Horizontal flexion and extension movements were performed at varying speeds by 10 subjects. EMD time in concentric contractions for biceps was 41 +/- 13 ms and for triceps was 26 +/- 11 ms and was not influenced by the velocity of the movement. In eccentric contractions at the slow velocity the biceps EMD time was 38 +/- 13 ms and shortened to 28 +/- 10 ms at the faster velocity. The eccentric triceps EMD, however, was not significantly altered by movement velocity and averag…