Search results for "Biomedical engineering"

showing 10 items of 2020 documents

Functional assessment of the quality of human hepatocyte preparations for cell transplantation.

2008

Hepatocyte transplantation is an alternative therapy to orthotopic liver transplantation for the treatment of liver diseases. Good quality freshly isolated or cryopreserved human hepatocytes are needed for clinical transplantation. However, isolation, cryopreservation, and thawing processes can seriously impair hepatocyte viability and functionality. The aim of the present study was to develop a fast and sensitive procedure to estimate the quality of hepatocyte preparations prior to clinical cell infusion. To this end, cell viability, attachment efficiency, and metabolic competence (urea synthesis and drug-metabolizing P450 activities) were selected as objective criteria. Viability of hepat…

AdultMaleQuality ControlPathologymedicine.medical_specialtyAdolescentCell SurvivalCell Transplantationmedicine.medical_treatmentCellBiomedical Engineeringlcsh:MedicineBiologyLiver transplantationCryopreservationSpecimen HandlingAndrologyYoung AdultCytochrome P-450 Enzyme SystemLiver Function TestsmedicineHumansUreaViability assayCells CulturedAgedTransplantationmedicine.diagnostic_testlcsh:RCell BiologyMiddle AgedTissue DonorsLiver TransplantationFibronectinTransplantationmedicine.anatomical_structureHepatocytebiology.proteinHepatocytesFemaleLiver function testsCell transplantation
researchProduct

Neural and mechanical responses of the triceps surae muscle group after 1 h of repeated fast passive stretches

2004

Experiments were carried out to examine interaction between mechanical changes of the muscletendon unit and reduced reflex sensitivity after repeated and prolonged passive muscle stretching (RPS). There is some evidence that this interaction might be relevant also during active stretch-shortening cycle type of fatigue tasks. The results demonstrated a clear deterioration of voluntarily and electrically induced muscle contractions after RPS. Maximal voluntary contraction (MVC), average electromyographic activities of the gastrocnemius and soleus muscles, and maximal twitch contraction decreased on average by 13.8, 10.4, 7.6, and 16.8%, respectively. In addition, there was a 14% lengthening …

AdultMaleReflex StretchPhysiologyElectromyographyMotor ActivityTendonsTriceps surae muscleReference ValuesPhysiology (medical)medicineHumansMuscle SkeletalMotor NeuronsProprioceptionmedicine.diagnostic_testElectromyographyChemistryMuscle adaptationAnatomyMotor unitmedicine.anatomical_structureTorqueReflexmedicine.symptomAnkleAnkle JointMuscle ContractionMuscle contractionBiomedical engineeringJournal of Applied Physiology
researchProduct

Stretch-reflex mechanical response to varying types of previous muscle activities

2002

This study was designed to examine the effects of varying types of background muscle activity on the stretch-reflex mechanical response. A rapid stretch was applied to the calf muscles after an isometric (pre-ISO), shortening (pre-SHO) and lengthening contraction (pre-LEN) with several pre-contraction levels, respectively. The stretch perturbation was applied with the tibio-tarsal joint angle at 90 degrees. The ankle joint torque elicited by the stretch showed a first peak (non-reflex torque: NRT), a transient drop and a second peak (reflex torque: RT). The muscle activities before the stretch clearly influenced the stretch-reflex mechanical response. The NRT reached the largest peak with t…

AdultMaleReflex StretchTime FactorsBiophysicsNeuroscience (miscellaneous)Isometric exerciseCalf musclesmedicineHumansStretch reflexMuscle activityMuscle SkeletalElectromyographyChemistryLengthening contractionAnatomymedicine.anatomical_structureTorqueJoint angleLinear ModelsReflexNeurology (clinical)AnkleAnkle JointMuscle ContractionBiomedical engineeringJournal of Electromyography and Kinesiology
researchProduct

Short-latency stretch reflex modulation in response to varying soleus muscle activities.

2002

The current investigation examined the effect of various types of background muscle contractions on the short-latency stretch reflex (SLR) elicited from the soleus muscle while subjects were in a sitting position. A stretch was applied to the calf muscles while they performed an isometric (pre-ISO), shortening (pre-SHO) and lengthening contraction (pre-LEN) with several pre-contraction levels. The ankle was at a 90 degrees tibio-tarsal joint angle when the perturbation was applied. Subjects developed and maintained a given pre-load level, which was maintained at various percentages of the maximum voluntary isometric plantar flexion torque. This was performed at 80 degrees in pre-SHO, 90 deg…

AdultMaleReflex StretchTime FactorsMuscle spindleBiophysicsNeuroscience (miscellaneous)Isometric exercisemedicineHumansShort latencyStretch reflexMuscle SkeletalSoleus muscleFourier AnalysisChemistryElectromyographyLengthening contractionAnatomyBiomechanical Phenomenamedicine.anatomical_structureTorqueNeurology (clinical)Anklemedicine.symptomAnkle JointBiomedical engineeringMuscle contractionMuscle ContractionJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

3D-printing-assisted fabrication of chitosan scaffolds from different sources and cross-linkers for dental tissue engineering

2021

The aim of the present study was to fabricate and characterise chitosan scaffolds from animal and fungal sources, with or without gelatine as a co-polymer, and cross-linked to 3-glycidyloxyproply trimethoxysilane (GPTMS) or genipin for application in dental root tissue engineering. Chitosan-based scaffolds were prepared by the emulsion freeze-drying technique. Scanning electron microscopy (SEM) and nano-focus computed tomography (nano-CT) were used to characterise scaffold microstructure. Chemical composition and cross-linking were evaluated by Fourier transform infrared-attenuated total reflectance spectroscopy. Compression tests were performed to evaluate scaffold mechanical properties. S…

AdultMaleScaffoldMaterials scienceRD1-811AdolescentCompressive StrengthScanning electron microscopeSimulated body fluid0206 medical engineeringBiocompatible MaterialsDiseases of the musculoskeletal system02 engineering and technologyApatiteChitosanYoung Adultchemistry.chemical_compoundTissue engineeringfungal chitosanDental pulp stem cellsMaterials TestingHumansIridoidsCells CulturedDental PulpChitosanTissue EngineeringTissue ScaffoldsStem Cellstechnology industry and agricultureSilanes020601 biomedical engineeringdental pulp stem cellsRC925-935chemistryvisual_artPrinting Three-Dimensionalvisual_art.visual_art_mediumGenipinSurgeryFemalePorosityBiomedical engineeringEuropean Cells and Materials
researchProduct

Autologous Iliac Bone Graft Compared with Biphasic Hydroxyapatite and Calcium Sulfate Cement for the Treatment of Bone Defects in Tibial Plateau Frac…

2019

Background Bone-graft substitutes are commonly used for the augmentation of traumatic bone defects in tibial plateau fractures. However, their clinical performance compared with that of autologous bone-grafting, the gold standard in bone defect reconstruction, still remains under debate. This study investigates the differences in quality of life, pain, and radiographic outcomes in the treatment of tibial plateau fracture-associated bone defects with either autologous bone grafts or a bioresorbable hydroxyapatite and calcium sulfate cement (CERAMENT BONE VOID FILLER [CBVF]; BONESUPPORT). Methods In this study, 135 patients with acute depression and split-depression fractures of the proximal …

AdultMaleScientific Articlesmedicine.medical_specialtyVisual analogue scaleRadiography0206 medical engineeringchemistry.chemical_element02 engineering and technology0170CalciumCalcium Sulfatelaw.inventionIliumFracture Fixation Internal03 medical and health sciences0302 clinical medicineRandomized controlled triallawMulticenter trialFracture fixationmedicineHumansOrthopedics and Sports MedicineProspective StudiesTibiaProspective cohort studyAged030222 orthopedicsBone Transplantationbusiness.industryBone CementsGeneral MedicineMiddle Aged020601 biomedical engineeringSurgeryTibial FracturesDurapatitechemistryQuality of LifeFemaleSurgerybusinessJournal of Bone and Joint Surgery
researchProduct

Ultrastructural study by backscattered electron imaging and elemental microanalysis of biomaterial-to-bone interface and mineral degradation of bovin…

2012

Objectives The aim of this study was to perform an ultrastructural study of the bone-to-biomaterial interface and biomaterial mineral degradation in retrieved bone biopsies following maxillary sinus augmentation using bovine xenografts (Endobon®) in 15 clinical cases. Materials and methods Nine months after sinus lifting, bone cores were harvested from the maxillary sinus. The specimens were processed for observation under a scanning electron microscope with backscattered electron imaging (SEM-BSE). In addition, chemical analysis and elemental mapping of the mineral composition were generated using a microanalytical system based on energy-dispersive X-ray spectrometry (EDX). Results No clin…

AdultMaleSinus Floor AugmentationMaxillary sinusScanning electron microscopeSurface PropertiesBiopsyDentistrySinus Floor AugmentationMicroanalysisSurgical FlapsmedicineAnimalsHumansSinus (anatomy)Chemistrybusiness.industryJaw Edentulous PartiallyDental Implantation EndosseousBiomaterialSpectrometry X-Ray EmissionMaxillary SinusMiddle AgedResorptionmedicine.anatomical_structureTreatment OutcomeElemental analysisMicroscopy Electron ScanningHeterograftsCattleFemaleCollagenOral SurgerybusinessBiomedical engineeringClinical oral implants research
researchProduct

Force-, EMG-, and elasticity-velocity relationships at submaximal, maximal and supramaximal running speeds in sprinters.

1986

The relationships between ground reaction forces, electromyographic activity (EMG), elasticity and running velocity were investigated at five speeds from submaximal to supramaximal levels in 11 male and 8 female sprinters. Supramaximal running was performed by a towing system. Reaction forces were measured on a force platform. EMGs were recorded telemetrically with surface electrodes from the vastus lateralis and gastrocnemius muscles, and elasticity of the contact leg was evaluated with spring constant values measured by film analysis. Data showed increases in most of the parameters studied with increasing running speed. At supramaximal velocity (10.36 +/- 0.31 m X s-1; 108.4 +/- 3.8%) the…

AdultMaleSpecific forcePhysiologyElectromyographyPublic Health Environmental and Occupational HealthSTRIDEGeneral MedicineAnatomyConcentricElasticityBiomechanical PhenomenaRunningPhysiology (medical)EccentricHumansOrthopedics and Sports MedicineForce platformFemaleGround reaction forceBiomechanics of sprint runningLung ComplianceBiomedical engineeringResultant forceMathematicsEuropean journal of applied physiology and occupational physiology
researchProduct

Do Stretch Durations Affect Muscle Mechanical and Neurophysiological Properties?

2016

International audience; The aim of the study was to determine whether stretching durations influence acute changes of mechanical and neurophysiological properties of plantar flexor muscles. Plantar flexors of 10 active males were stretched in passive conditions on an isokinetic dynamometer. Different durations of static stretching were tested in 5 randomly ordered experimental trials (1, 2, 3, 4 and 10×30-s). Fascicle stiffness index, evoked contractile properties and spinal excitability (Hmax/Mmax) were examined before (PRE), immediately after (POST0) and 5 min after (POST5) stretching. No stretch duration effect was recorded for any variable. Moreover, whatever the stretching duration, st…

AdultMaleTime FactorsM waveStiffness indexPhysical Therapy Sports Therapy and RehabilitationPlantar flexionStatic stretchingYoung Adult03 medical and health sciencesstiffness0302 clinical medicineMuscle Stretching Exercises[SDV.MHEP.PHY]Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO]medicineHumansOrthopedics and Sports MedicineH reflexMuscle Skeletalsoleusdose-responseFootChemistry[ SDV.MHEP.PHY ] Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO]030229 sport sciencesAnatomyNeurophysiologyFascicleTorqueIsokinetic dynamometermedicine.symptomH-reflex030217 neurology & neurosurgeryMuscle ContractionMuscle contractionBiomedical engineering
researchProduct

Electromechanical delay in skeletal muscle under normal movement conditions.

1979

Electromechanical delays (EMD), the time from onset of EMG activity to change in acceleration or deceleration of the forearm, were studied in concentric and eccentric contractions of biceps and triceps brachii muscles. Horizontal flexion and extension movements were performed at varying speeds by 10 subjects. EMD time in concentric contractions for biceps was 41 +/- 13 ms and for triceps was 26 +/- 11 ms and was not influenced by the velocity of the movement. In eccentric contractions at the slow velocity the biceps EMD time was 38 +/- 13 ms and shortened to 28 +/- 10 ms at the faster velocity. The eccentric triceps EMD, however, was not significantly altered by movement velocity and averag…

AdultMaleTime FactorsPhysiologyMovementElectromyographyConcentricBicepsAccelerationForearmmedicineEccentricHumansPhysicsmedicine.diagnostic_testElectromyographySkeletal muscleAnatomyElasticityForearmmedicine.anatomical_structureFemalemedicine.symptomMuscle contractionBiomedical engineeringMuscle ContractionActa physiologica Scandinavica
researchProduct