Search results for "Biomedical"

showing 10 items of 2328 documents

<title>Potential of advanced photoplethysmography sensing for noninvasive vascular diagnostics and early screening</title>

2002

Advanced sensor device for shape analysis of the tissue- reflected mean single period photoplethysmography (SPPPG) signals has been designed and clinically tested. The SPPPG signal shape reveals individual features of the patient's cardio-vascular state. Clinical studies of several patient groups (e.g. diabetes mellitus, atherosclerosis obliterans, Raynaud's syndrome) made possible to specify components of the SPPPG signal that are sensitive to the corresponding organic or functional pathologies. Comparison of the right and left arm finger SPPPG signal shapes, for instance, appears to be efficient tool for early screening of unilateral atherosclerosis obliterans.© (2002) COPYRIGHT SPIE--The…

medicine.medical_specialtybusiness.industryPhotoplethysmogrammedicineRadiologybusinessBiomedical engineeringSPIE Proceedings
researchProduct

Die Röntgendigitalanlage als Instrument zur kinematischen Untersuchung der Schulter — Eine Untersuchung zur Strahlenbelastung - Digital Radiography a…

1991

The radiation exposure during biomechanical investigation of the shoulder joint done with a digital radiography system (Polytron 1000 VR - Siemens) was measured experimentally. Total radiation dose and surface dose were determined by phantom measurements. The radiation exposure per image is about 1/6 to 1/7 of that of a conventional study. The digital radiography system used is thus suitable for kinesiologic studies of large joints in healthy volunteers.

medicine.medical_specialtybusiness.industryRadiation doseBiomedical EngineeringRoentgenKinematicsRadiationImaging phantomSurgeryRadiation exposuresymbols.namesakemedicine.anatomical_structuresymbolsMedicineShoulder jointbusinessNuclear medicineDigital radiographyBiomedizinische Technik/Biomedical Engineering
researchProduct

Correlation between clinical and radiographic classification of osteoarthritis and SNPs linked to osteoarthritis susceptibility

2013

medicine.medical_specialtybusiness.industryRadiographyBiomedical EngineeringSingle-nucleotide polymorphismOsteoarthritismedicine.diseaseCorrelationSNP OsteoarthritisRheumatologyInternal medicineMedicineOrthopedics and Sports MedicinebusinessOsteoarthritis and Cartilage
researchProduct

Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes

2014

Objective The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. Methods The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills w…

medicine.medical_specialtybusiness.industrySyringesRoboticsCleaning validation030226 pharmacology & pharmacySurgeryPharmaceutical Solutions03 medical and health sciencesContamination rate0302 clinical medicineRobotic systemsOncologyTechnology PharmaceuticalMedicinePharmacology (medical)030212 general & internal medicineAseptic processingDrug ContaminationbusinessAsepsisBiomedical engineeringJournal of Oncology Pharmacy Practice
researchProduct

The anatomy of the heart in the sonogram. A comparison between anatomic and ultrasonic cross-section.

1977

Cardiac sonography has only recently been introduced as a diagnostic procedure. In order to facilitate the interpretation and evaluation of the ultrasonic cardiac cross-section displayed by this two-dimensional technique, we performed anatomic cross-sections corresponding to ultrasonic cross-sections. The ultrasonic cross-sectional images were taken from children with a real-time-motion scanner. The anatomic cross-sections were taken from adult hearts. Two ultrasonic transverse cross-sections are compared with the two corresponding anatomic cross-sections and three ultrasonic longitudinal cross-sections with one corresponding anatomic cross-section. The direct comparison between anatomic an…

medicine.medical_specialtybusiness.industryUltrasoundHeartIn Vitro TechniquesCross section (geometry)EchocardiographyPediatrics Perinatology and Child HealthMedicineHumansRadiology Nuclear Medicine and imagingUltrasonic sensorTomographyRadiologybusinessChildTomographyBiomedical engineeringPediatric radiology
researchProduct

Tissue classification by texture and spectral analysis of intracoronary ultrasound radio-frequency data

2002

Imaging of vascular structures by intracoronary ultrasound allows in principal the recognition of different lesion types due to the echomorphology in the B-mode image. The subjective visual diagnosis is often difficult, especially the differentiation between thrombi and non-calcified plaque. The aim of this study was the extraction of features from the ultrasound radio-frequency signal for an objective characterization of coronary tissue. Methods of texture analysis and frequency analysis were used to differentiate red and white thrombi in vitro. Eight texture parameters of first and second order significantly differentiated red and white thrombi. The backscatter transfer function of red th…

medicine.medical_specialtybusiness.industryUltrasoundLesion typesmedicine.diseaseTexture (geology)Image texturecardiovascular systemMedicineIntracoronary ultrasoundSpectral analysiscardiovascular diseasesRadio frequencyRadiologyThrombusbusinesscirculatory and respiratory physiologyBiomedical engineeringComputers in Cardiology 1995
researchProduct

Usability of photoplethysmography method in estimation of conduit artery stiffness

2011

Three channel photoplethysmography (PPG) signal waveform studies of leg conduit arteries during a provocative occlusion test were performed. PPG waveform second derivative amplitude ratio and arterial pulse wave velocity values showed significant correlations with ultrasound (US) reference method of local and regional arterial stiffness (AS), showing the ability to use PPG for AS change quantitative assessment.

medicine.medical_specialtybusiness.industryUltrasoundmedicine.diseaseSignalmedicine.anatomical_structurePhotoplethysmogramOcclusionArterial stiffnessMedicineWaveformsense organsRadiologybusinessArterySecond derivativeBiomedical engineeringSPIE Proceedings
researchProduct

Modeling the pelvic region for non-invasive pelvic intraoperative neuromonitoring

2016

Abstract Finite element analysis (FEA) of electric current distribution in the pelvis minor may help to assess the usability of non-invasive surface stimulation for continuous pelvic intraoperative neuromonitoring. FEA requires generation of quality volumetric tetrahedral mesh geometry. This study proposes the generation of a suitable mesh based on MRI data. The resulting volumetric mesh models the autonomous nerve structures at risk during total mesorectal excision. The model also contains the bone, cartilage, fat, skin, muscle tissues of the pelvic region, and a set of electrodes for surface stimulation. The model is ready for finite element analysis of the discrete Maxwell’s equations.

medicine.medical_specialtybusiness.industryfinite element methodlcsh:RNon invasiveBiomedical Engineeringlcsh:Medicinepelvic intraoperative neurophysiological monitoring03 medical and health sciences0302 clinical medicinemedicine.anatomical_structure030220 oncology & carcinogenesismedicine030211 gastroenterology & hepatologyelectric field modelingRadiologybusinessPelvisCurrent Directions in Biomedical Engineering
researchProduct

CAPD + Hemoperfusion Once a Week for End Stage Renal Disease

1982

medicine.medical_specialtybusiness.industrymedicine.medical_treatment030232 urology & nephrologyBiomedical EngineeringUrologyMedicine (miscellaneous)BioengineeringGeneral Medicine030204 cardiovascular system & hematologyHemoperfusionEnd stage renal diseaseBiomaterials03 medical and health sciences0302 clinical medicineText miningmedicinebusinessThe International Journal of Artificial Organs
researchProduct

Biomechanical evaluation of a new treatment method for distal tibia fractures

2015

Distal tibial fractures are often the result of high-energy impacts combined with excessive soft tissue injury. Treatment options include either open reduction and internal fixation usually as a mi...

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentBiomedical EngineeringBiomechanicsTreatment optionsTreatment methodBioengineeringGeneral Medicinemedicine.diseaseDistal tibiaComputer Science Applicationslaw.inventionSurgeryHuman-Computer InteractionIntramedullary rodlawSoft tissue injurymedicineInternal fixationbusinessReduction (orthopedic surgery)Computer Methods in Biomechanics and Biomedical Engineering
researchProduct