Search results for "Biomedical"

showing 10 items of 2328 documents

Potentiation of the mechanical behavior of the human skeletal muscle through prestretching

1979

Force-velocity and power-velocity curves in a vertical jump involving movements around several joints were derived from vertical ground reaction forces and knee angular velocities. The jumps were performed with weights from 10 to 160 kg added on the shoulders. The obtained curves from a semi-squatting static starting position resembled those reported for isolated muscles or single muscle groups. Vertical jumps were also performed in the conditions where the shortening of the leg extensors was preceded by prestretching of the active muscles either through a preparatory counter-movement or dropping down on the force-platform from the various heights ranging from 20 to 100 cm. Prestretching mo…

AdultMalePhysiologyChemistryMusclesElastic energySkeletal muscleLong-term potentiationMuscle activationAnatomyElasticityVertical jumpmedicine.anatomical_structureReflexmedicineHumansGround reaction forceMechanical energyBiomedical engineeringActa Physiologica Scandinavica
researchProduct

The effect of pre-stretch on mechanical efficiency of human skeletal muscle

1987

The mechanical efficiency of positive work was studied in six subjects performing three different types of exercises. On the first occasion the subjects ran on a motor-driven treadmill at 3.33 m s-1; the second and the third exercises consisted of performing rhythmical vertical jumps for 1 min both in rebound (RJ) and no-rebound (NRJ) conditions. The mechanical efficiency calculated in NRJ, which reflects only the conversion of biochemical energy into mechanical work, was found to be lower than the corresponding observation in RJ, 17.2 vs. 27.8% (P less than 0.001), respectively. These differences could not be explained by only the storage and recoil of elastic energy occurring in RJ compar…

AdultMalePhysiologyChemistryPhysical ExertionWork (physics)Elastic energySkeletal muscleAnatomymedicine.disease_causeElasticityStretch shortening cycleRunningPre stretchJumpingmedicine.anatomical_structuremedicineJumpHumansTreadmillMechanoreceptorsMuscle ContractionBiomedical engineeringActa Physiologica Scandinavica
researchProduct

Effect of electrode location on surface electromyography changes due to eccentric elbow flexor exercise.

2009

Experiments were carried out to determine whether the location of electrodes has an effect on eccentric exercise–induced changes in surface electromyography (sEMG) variables in the biceps brachii muscle. sEMG signals were recorded with a grid of 64 electrodes before and up to 4 days post-exercise. Root mean square (RMS) and mean power frequency (MNF) were calculated for: (1) each channel; (2) as an average of all channels; and (3) as an average of individual channel rows and columns. Mean muscle-fiber conduction velocity (CV) was estimated similarly but was based on double-differential channels. Maximal isometric voluntary torque decreased 21.3 ± 5.6% post-exercise. The average sEMG variabl…

AdultMalePhysiologyMuscle Fibers SkeletalPainElectromyographyIsometric exerciseNerve conduction velocityRoot mean squareCellular and Molecular NeurosciencePhysiology (medical)Isometric ContractionmedicineElbowEccentricHumansMuscle SkeletalElectrodesExerciseMathematicsMuscle fatiguemedicine.diagnostic_testBiceps brachii muscleElectromyographySignal Processing Computer-AssistedAnatomyElectrode locationNeurology (clinical)Biomedical engineeringMuscle ContractionMusclenerve
researchProduct

Influence of dental occlusion conditions on plantar pressure distribution during standing and walking – A gender perspective

2021

Abstract The aim of this study was to investigate gender-specific influences of different symmetric and asymmetric occlusion conditions on postural control during standing and walking. The study involved 59 healthy adult volunteers (41 f/19 m) aged between 22 and 53 years (30.2 ± 6.3 years). Postural control measurements were carried out using a pressure plate by measuring plantar pressure distribution during standing and walking test conditions. Seven different occlusion conditions were tested. Prior to a MANOVA model analysis, the relationship between the two test conditions were checked using a factor analysis with a varying number of factors (between 2 and 10). The plantar pressure dist…

AdultMalePressure plateCoefficient of variation0206 medical engineeringBiomedical EngineeringBiophysicsWalking02 engineering and technologyPostural controlDental OcclusionYoung Adult03 medical and health sciences0302 clinical medicineMultivariate analysis of varianceOcclusionPressureHumansMedicinePostural BalanceOrthodonticsFootbusiness.industryDental occlusionPlantar pressureMiddle Aged020601 biomedical engineeringSplintsFemalebusiness030217 neurology & neurosurgeryMedical Engineering & Physics
researchProduct

Non-contact breath sampling for sensor-based breath analysis

2019

Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a…

AdultMalePulmonary and Respiratory MedicineSpectrum analyzer:MEDICINE [Research Subject Categories]breath samplingDiaphragmatic breathingContext (language use)01 natural sciencesYoung Adult03 medical and health sciences0302 clinical medicinevolatile organic compoundsHumansbreath analysisVolatile Organic CompoundsRespiration010401 analytical chemistryBreath samplingExhalationSampling (statistics)Middle AgedPTR-MS0104 chemical sciencesBreath Tests030228 respiratory systemBreath gas analysisBreathingEnvironmental scienceFemaleBiomedical engineeringJournal of Breath Research
researchProduct

Functional assessment of the quality of human hepatocyte preparations for cell transplantation.

2008

Hepatocyte transplantation is an alternative therapy to orthotopic liver transplantation for the treatment of liver diseases. Good quality freshly isolated or cryopreserved human hepatocytes are needed for clinical transplantation. However, isolation, cryopreservation, and thawing processes can seriously impair hepatocyte viability and functionality. The aim of the present study was to develop a fast and sensitive procedure to estimate the quality of hepatocyte preparations prior to clinical cell infusion. To this end, cell viability, attachment efficiency, and metabolic competence (urea synthesis and drug-metabolizing P450 activities) were selected as objective criteria. Viability of hepat…

AdultMaleQuality ControlPathologymedicine.medical_specialtyAdolescentCell SurvivalCell Transplantationmedicine.medical_treatmentCellBiomedical Engineeringlcsh:MedicineBiologyLiver transplantationCryopreservationSpecimen HandlingAndrologyYoung AdultCytochrome P-450 Enzyme SystemLiver Function TestsmedicineHumansUreaViability assayCells CulturedAgedTransplantationmedicine.diagnostic_testlcsh:RCell BiologyMiddle AgedTissue DonorsLiver TransplantationFibronectinTransplantationmedicine.anatomical_structureHepatocytebiology.proteinHepatocytesFemaleLiver function testsCell transplantation
researchProduct

Neural and mechanical responses of the triceps surae muscle group after 1 h of repeated fast passive stretches

2004

Experiments were carried out to examine interaction between mechanical changes of the muscletendon unit and reduced reflex sensitivity after repeated and prolonged passive muscle stretching (RPS). There is some evidence that this interaction might be relevant also during active stretch-shortening cycle type of fatigue tasks. The results demonstrated a clear deterioration of voluntarily and electrically induced muscle contractions after RPS. Maximal voluntary contraction (MVC), average electromyographic activities of the gastrocnemius and soleus muscles, and maximal twitch contraction decreased on average by 13.8, 10.4, 7.6, and 16.8%, respectively. In addition, there was a 14% lengthening …

AdultMaleReflex StretchPhysiologyElectromyographyMotor ActivityTendonsTriceps surae muscleReference ValuesPhysiology (medical)medicineHumansMuscle SkeletalMotor NeuronsProprioceptionmedicine.diagnostic_testElectromyographyChemistryMuscle adaptationAnatomyMotor unitmedicine.anatomical_structureTorqueReflexmedicine.symptomAnkleAnkle JointMuscle ContractionMuscle contractionBiomedical engineeringJournal of Applied Physiology
researchProduct

Stretch-reflex mechanical response to varying types of previous muscle activities

2002

This study was designed to examine the effects of varying types of background muscle activity on the stretch-reflex mechanical response. A rapid stretch was applied to the calf muscles after an isometric (pre-ISO), shortening (pre-SHO) and lengthening contraction (pre-LEN) with several pre-contraction levels, respectively. The stretch perturbation was applied with the tibio-tarsal joint angle at 90 degrees. The ankle joint torque elicited by the stretch showed a first peak (non-reflex torque: NRT), a transient drop and a second peak (reflex torque: RT). The muscle activities before the stretch clearly influenced the stretch-reflex mechanical response. The NRT reached the largest peak with t…

AdultMaleReflex StretchTime FactorsBiophysicsNeuroscience (miscellaneous)Isometric exerciseCalf musclesmedicineHumansStretch reflexMuscle activityMuscle SkeletalElectromyographyChemistryLengthening contractionAnatomymedicine.anatomical_structureTorqueJoint angleLinear ModelsReflexNeurology (clinical)AnkleAnkle JointMuscle ContractionBiomedical engineeringJournal of Electromyography and Kinesiology
researchProduct

Short-latency stretch reflex modulation in response to varying soleus muscle activities.

2002

The current investigation examined the effect of various types of background muscle contractions on the short-latency stretch reflex (SLR) elicited from the soleus muscle while subjects were in a sitting position. A stretch was applied to the calf muscles while they performed an isometric (pre-ISO), shortening (pre-SHO) and lengthening contraction (pre-LEN) with several pre-contraction levels. The ankle was at a 90 degrees tibio-tarsal joint angle when the perturbation was applied. Subjects developed and maintained a given pre-load level, which was maintained at various percentages of the maximum voluntary isometric plantar flexion torque. This was performed at 80 degrees in pre-SHO, 90 deg…

AdultMaleReflex StretchTime FactorsMuscle spindleBiophysicsNeuroscience (miscellaneous)Isometric exercisemedicineHumansShort latencyStretch reflexMuscle SkeletalSoleus muscleFourier AnalysisChemistryElectromyographyLengthening contractionAnatomyBiomechanical Phenomenamedicine.anatomical_structureTorqueNeurology (clinical)Anklemedicine.symptomAnkle JointBiomedical engineeringMuscle contractionMuscle ContractionJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

3D-printing-assisted fabrication of chitosan scaffolds from different sources and cross-linkers for dental tissue engineering

2021

The aim of the present study was to fabricate and characterise chitosan scaffolds from animal and fungal sources, with or without gelatine as a co-polymer, and cross-linked to 3-glycidyloxyproply trimethoxysilane (GPTMS) or genipin for application in dental root tissue engineering. Chitosan-based scaffolds were prepared by the emulsion freeze-drying technique. Scanning electron microscopy (SEM) and nano-focus computed tomography (nano-CT) were used to characterise scaffold microstructure. Chemical composition and cross-linking were evaluated by Fourier transform infrared-attenuated total reflectance spectroscopy. Compression tests were performed to evaluate scaffold mechanical properties. S…

AdultMaleScaffoldMaterials scienceRD1-811AdolescentCompressive StrengthScanning electron microscopeSimulated body fluid0206 medical engineeringBiocompatible MaterialsDiseases of the musculoskeletal system02 engineering and technologyApatiteChitosanYoung Adultchemistry.chemical_compoundTissue engineeringfungal chitosanDental pulp stem cellsMaterials TestingHumansIridoidsCells CulturedDental PulpChitosanTissue EngineeringTissue ScaffoldsStem Cellstechnology industry and agricultureSilanes020601 biomedical engineeringdental pulp stem cellsRC925-935chemistryvisual_artPrinting Three-Dimensionalvisual_art.visual_art_mediumGenipinSurgeryFemalePorosityBiomedical engineeringEuropean Cells and Materials
researchProduct