Search results for "Biomedical"

showing 10 items of 2328 documents

A Polyphenylene Dendrimer Drug Transporter with Precisely Positioned Amphiphilic Surface Patches

2014

The design and synthesis of a polyphenylene dendrimer (PPD 3) with discrete binding sites for lipophilic guest molecules and characteristic surface patterns is presented. Its semi-rigidity in combination with a precise positioning of hydrophilic and hydrophobic groups at the periphery yields a refined architecture with lipophilic binding pockets that accommodate defined numbers of biologically relevant guest molecules such as fatty acids or the drug doxorubicin. The size, architecture, and surface textures allow to even penetrate brain endothelial cells that are a major component of the extremely tight blood-brain barrier. In addition, low to no toxicity is observed in in vivo studies using…

DendrimersScaffoldEmbryo NonmammalianMaterials sciencePolymersStereochemistryBiomedical EngineeringPharmaceutical ScienceChemistry Techniques SyntheticBlood–brain barrierCell LineBiomaterialsMiceIn vivoDendrimerAmphiphilemedicineAnimalsHumansMoleculeTissue DistributionBinding siteZebrafishDrug CarriersBrainEndothelial CellsTransportermedicine.anatomical_structureDoxorubicinDrug DesignBiophysicsHydrophobic and Hydrophilic InteractionsAdvanced Healthcare Materials
researchProduct

Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation

2012

Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…

Dental ImplantsCone beam computed tomographymedicine.medical_specialtyComputer scienceDental Implantation EndosseousCone-Beam Computed Tomographycomputer.software_genreModels DentalPatient Care PlanningSurgeryDental implant surgeryImaging Three-DimensionalDental Prosthesis DesignSurgery Computer-AssistedVoxelPosition (vector)Vertical directionRange (statistics)medicineHumansImplantOral SurgeryFrontal regioncomputerBiomedical engineeringClinical Oral Implants Research
researchProduct

The funding sources of implantology research in the period 2008-2017: A bibliometric analysis

2019

BACKGROUND Implant dentistry is subject to major economic pressures as a result of the growth in the manufacturing and commercialization of dental implants. PURPOSE To examine research funding in implant dentistry by means of a bibliometric analysis of articles indexed in Web of Science (WoS) published during the period 2008-2017. MATERIALS AND METHODS The search was conducted applying the truncated term "implant*" in the WoS dentistry area. Only items labeled as "article" or "review" were selected. Records were manually refined and normalized to unify terms and to remove typographical, transcription, and/or indexing errors. RESULTS A total of 14 255 records were identified for analysis. Ab…

Dental ImplantsGovernmentBibliometric analysisWeb of scienceImplant dentistry0206 medical engineeringLibrary scienceSubject (documents)030206 dentistry02 engineering and technology020601 biomedical engineering03 medical and health sciences0302 clinical medicineBibliometricsDentistryPolitical scienceOral SurgeryCitationGeneral Dentistryhealth care economics and organizationsPeriod (music)Clinical Implant Dentistry and Related Research
researchProduct

Early bone healing around implant surfaces treated with variations in the resorbable blasting media method. A study in rabbits.

2010

Objective: this study aimed to histomorphologically and histomorphometrically evaluate the in vivo response to three variations in the resorbable blasting media (RBM) surface processing in a rabbit femur model. Study Design: screw root form implants with 3.75 mm in diameter by 8 mm in length presenting four surfaces (n=8 each): alumina-blasted/acid-etched (AB/AE), bioresorbable ceramic blasted (TCP), TCP + acid etching, and AB/AE + TCP were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The implants were placed at the distal femur of 8 New Zeland rabbits, remaining for 2 weeks in vivo. After sacrifice, the implants were nondecalcified processed to 30 …

Dental ImplantsMaterials scienceSurface PropertiesScanning electron microscopeAtomic force microscopymedicine.medical_treatmentBone healing:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyUNESCO::CIENCIAS MÉDICASDental EtchingMicroscopy Electron ScanningmedicineAnimalsSurgeryFemurFemurRabbitsDental EtchingImplantDental implantGeneral DentistryRock blastingBiomedical engineeringMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Three-dimensional scanning electron microscopy of maxillofacial biomaterials

2017

Dental Implantsbusiness.industryScanning electron microscopeOral Surgical Procedures010401 analytical chemistryBiocompatible Materials030206 dentistry01 natural sciences0104 chemical scienceslaw.invention03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineOtorhinolaryngologylawMicroscopy Electron ScanningMedicineSurgeryOral SurgeryElectron microscopebusinessThree dimensional scanningBiomedical engineeringBritish Journal of Oral and Maxillofacial Surgery
researchProduct

Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.

2020

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…

Dental InstrumentsHot Temperatureincidence angle0206 medical engineeringStatistical differencecutting efficiency02 engineering and technology03 medical and health sciencesReciprocating motion0302 clinical medicineNickelStatisticsMaterials TestingGeneral DentistryIncidence (geometry)MathematicsTitaniumheat treatmentIncidenceSignificant difference030206 dentistryEquipment Designreciproc blue020601 biomedical engineeringNickel titaniumHeat treatedreciprocationCalipersRoot Canal PreparationAustralian endodontic journal : the journal of the Australian Society of Endodontology IncReferences
researchProduct

Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.

2015

Objective The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Material and methods Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectros…

Dental InstrumentsMaterials scienceSpectrophotometry InfraredSwinemedicine.medical_treatmentDentistryIn Vitro TechniquesOsteotomy03 medical and health sciences0302 clinical medicinemedicineAnimalsPiezosurgery030223 otorhinolaryngologyPiezosurgeryDental ImplantsDrillbusiness.industryDental Implantation Endosseous030206 dentistryDental instrumentsOsteotomyResonance frequency analysismedicine.anatomical_structureTorqueCortical boneImplantOral SurgerybusinessCancellous boneBiomedical engineeringClinical oral implants research
researchProduct

Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection

2020

The bioengineering and medical and biomedical fields are ever closer, and they manage to obtain surprising results for the development of new devices. The field of simulations and studies in silica has undergone considerable development in recent years, favoring the advancement of medicine. In this manuscript, a study was carried out to evaluate the force distribution on the implant components (In-Kone® Universal) and on the peri-implant tissues subjected to loading. With the finite element analysis and the Von Mises method, it was possible to evaluate this distribution of forces both at 0 degrees (occlusal force) and at 30 degrees; the applied force was 800 N. The obtained results on this …

Dental Stress AnalysisField (physics)Article SubjectComputer sciencemedicine.medical_treatmentFinite Element AnalysisBiomedical EngineeringGeneral Biochemistry Genetics and Molecular BiologyBone and BonesBite ForceStress (mechanics)03 medical and health sciences0302 clinical medicinemedicinevon Mises yield criterionHumansDental implantDental ImplantsGeneral Immunology and Microbiologybusiness.industryR030206 dentistryGeneral MedicineConical surfaceStructural engineeringFinite element methodConnection (mathematics)MedicineDevelopment (differential geometry)Stress Mechanicalbusiness030217 neurology & neurosurgeryFinite Element Method Von Mises Investigation Bone Response Conical Dental Implant ConnectionResearch Article
researchProduct

The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study

2011

Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…

Dental Stress Analysisbone mechanical responseMaterials scienceimplant-abutment stresFinite Element AnalysisPlatform switchingDental Abutmentsimplant-abutment stressFinite element studyImaging Three-Dimensionalvon Mises yield criterionGeneral Dentistryplatform switchingDental Implant-Abutment Designfinite element analysis; implant-abutment stress; bone mechanical response; platform switching; implant-abutment stres:CIENCIAS MÉDICAS [UNESCO]Finite element methodBiomechanical PhenomenaStress fieldPlatform switching bone mechanical response finite element analysis implant-abutment stress.Dental Implant-Abutment DesignOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryImplantAbutment (dentistry)Biomedical engineering
researchProduct

Remote photoplethysmography for assessment of oral mucosa

2019

The present study is devoted to the assessment of oral mucosa perfusion using remote photoplethysmography (rPPG) technique. The alterations of mucosal perfusion were evoked by regional infiltration anesthesia containing adrenaline. Simple rPPG setup comprising white LED light source, video camera and narrowband optical filter (CWL=540nm), are able to detect subtle microcirculation changes in gingiva. Results demonstrate substantial decrease of rPPG waveform amplitude and subsequently perfusion index in affected gingiva region, following administration of anesthetics. The present study emphasizes clinical advantages of remote photoplethysmography and perfusion index mapping as a simple and c…

Dental anesthesiaLight sourcemedicine.anatomical_structureInfiltration anesthesiabusiness.industryPhotoplethysmogrammedicineOral mucosaLaser Doppler velocimetrybusinessPerfusionMicrocirculationBiomedical engineeringClinical and Preclinical Optical Diagnostics II
researchProduct