Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes

2003

Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…

AdultBiometryVisual acuityAdolescentLightPseudophakiagenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalEyeRefraction OcularCataractOptical biometryLens Implantation IntraocularHumansMedicineChildAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industryUltrasoundMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOptical axisOphthalmologyInterferometryChild PreschoolOptometrySurgerysense organsmedicine.symptombusinessPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

A simple description of age-related changes in crystalline lens thickness.

2010

Purpose An increase in lens thickness is often described as a linear function of age. However, contradictory opinions exist about whether the lens thickness continues to increase after 50 years of age. Differences in slope exist between this increase in younger and older people, but these findings are inconsistent with the linear behavior of an increase in the lens thickness throughout life. We investigated among different functions, including slope variation, which would be the best to show the relation between lens thickness and age. An available model portraying lens growth could be advantageous in many practical applications. The possibility of differences between sexes in lens thicknes…

AdultMaleAgingBiometryAdolescentLens (geology)03 medical and health sciencesYoung Adult0302 clinical medicineStatistical variabilityLens thicknessAge relatedStatisticsLens CrystallineRange (statistics)HumansMathematicsAgedAged 80 and overLinear function (calculus)General MedicineMiddle AgedOphthalmology030221 ophthalmology & optometryFemaleOlder people030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer

2018

Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…

AdultMaleAgingRefractive errormedicine.medical_specialtyBiometryIntraclass correlationBiomedical Engineering030204 cardiovascular system & hematologyAstigmatismStandard deviationlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineLens thicknessAge groupslawOphthalmologyLens CrystallinemedicineHumansMathematicsKeratometerAge FactorsReproducibility of ResultsGeneral MedicineRepeatabilityMiddle AgedRefractive Errorsmedicine.diseaseAxial Length EyeFemaleSurgeryTomography Optical Coherence030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability

2001

Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…

AdultMaleBiometryLightInterobserver reliabilityAnterior ChamberEmmetropiaData descriptionCorneaOptical biometryOpticsMyopiaHumansReliability (statistics)AgedMathematicsObserver VariationReproducibilitybusiness.industryCorneal TopographyReproducibility of ResultsMiddle AgedSensory SystemsOphthalmologyInterferometryPartial coherence interferometryFemaleSurgerybusinessNuclear medicinePartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Interchangeability among five devices that measure anterior eye distances.

2014

The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…

AdultMaleBiometrybusiness.industryAnterior ChamberMeasure (physics)Corneal TopographyReproducibility of ResultsEquipment DesignRefraction OcularRefractive ErrorsInterchangeabilityCorneaOphthalmologyYoung AdultOpticsOptometryMedicineHumansFemaleProspective StudiesbusinessOptometryFollow-Up StudiesClinicalexperimental optometry
researchProduct

Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.

2020

To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p  0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …

AdultMaleBiometrygenetic structuresBiometricsComputer scienceAnterior ChamberBiomedical EngineeringHigh resolution030204 cardiovascular system & hematologyEye03 medical and health sciencesYoung Adult0302 clinical medicineOpticsOptical coherence tomographyLens CrystallinemedicineHumansAgedmedicine.diagnostic_testbusiness.industryReproducibility of ResultsPupilGeneral MedicineCoherence (statistics)RepeatabilityMiddle Agedeye diseasesSurgeryFemalesense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation

2009

PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyRefractive errorBiometryAdolescentgenetic structuresEye diseasePhakic intraocular lensVision disorderYoung Adult03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansBody Weights and MeasuresImplantable collamer lensScience & Technologybusiness.industryOutcome measuresMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVault (architecture)Implantable Contact Lens030221 ophthalmology & optometryOptometryFemalesense organsmedicine.symptombusinessTomography Optical Coherence030217 neurology & neurosurgeryAmerican Journal of Ophthalmology
researchProduct

Evaluation of Physiological Parameters on Discomfort Glare Thresholds Using LUMIZ 100 Tool

2021

Purpose To assess the links between discomfort glare sensitivity and physiological factors such as eye biometry, refraction, skin phototype, age, and gender among a large sample of healthy human subjects. Methods A total of 489 participants who were 20 to 70 years old (241 men, 248 women) underwent discomfort glare threshold measurements via the LUMIZ 100. Eye biometry and optical quality were measured using a Zeiss IOLMaster 700 biometer and i.Profiler aberrometer. Iris color, skin tone, age, gender, eyeglasses use, chronotype, fatigue level, self-evaluation of light sensitivity, and time spent outdoors were determined. Statistical analysis was carried out using nonparametric Mann–Whitney …

AdultMalediscomfortiris colormedicine.medical_specialtyBiometrygenetic structuresPhotophobiaPopulationVision DisordersBiomedical EngineeringFrequency of usepupilAudiologyArticleIris colorYoung AdultHumansMedicineeducationFatigueAgededucation.field_of_studyLight sensitivitysunglasses usebusiness.industryskin toneGlare (vision)ChronotypeglareMiddle AgedOptical qualityOphthalmologyEyeglasseschronotypeFemalehealthy populationmedicine.symptomlightbusinessTranslational Vision Science & Technology
researchProduct

Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

2019

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …

AdultMalemedicine.medical_specialtyBiometryHigh resolutionVergenceStatistics NonparametricYoung Adult03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOptical coherence tomographyReference ValuesOphthalmologyHumansMedicineTomographyMúsculo ciliarBiometriaAnalysis of Variancemedicine.diagnostic_testbusiness.industryCiliary BodyOptical coherenceBiomechanicsAccommodation OcularPresbyopiaGeneral MedicinePresbyopiamedicine.diseaseBiomechanical PhenomenaCiliary muscleOphthalmologyCiliary musclelcsh:RE1-994Acomodação ocularTomografia de coerência ópticaAccommodation ocularLinear Models030221 ophthalmology & optometryPositive relationshipFemalesense organsPresbiopiabusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct