Search results for "Blood"
showing 10 items of 5199 documents
The Effects of Sympathetic Inhibition on Metabolic and Cardiopulmonary Responses to Exercise in Hypoxic Conditions.
2015
Objective Pre-exertion skeletal muscle glycogen content is an important physiological determinant of endurance exercise performance: low glycogen stores contribute to premature fatigue. In low-oxygen environments (hypoxia), the important contribution of carbohydrates to endurance performance is further enhanced as glucose and glycogen dependence is increased; however, the insulin sensitivity of healthy adult humans is decreased. In light of this insulin resistance, maintaining skeletal muscle glycogen in hypoxia becomes difficult, and subsequent endurance performance is impaired. Sympathetic inhibition promotes insulin sensitivity in hypoxia but may impair hypoxic exercise performance, in p…
Clonidine induces nitric oxide- and prostaglandin-mediated vasodilation in healthy human skin
2005
Sustained sympathetic activation not only leads to vasoconstriction but also might induce paradox vasodilation. This study was performed to explore whether and how alpha(2)-receptor stimulation mediates this vasodilation. We investigated 11 healthy subjects in 33 dermal microdialysis (MD) sessions. After nerve trunk blockade, MD fibers were inserted and perfused with physiological saline until skin trauma-related vasodilation subsided. Thereafter, fibers were perfused with either clonidine solutions (10(-3), 5 x 10(-4), 10(-4) mol/l), N(G)-monomethyl-l-arginine (L-NMMA; nitric oxide synthase blocker), acetylsalicylic acid (ASA; cyclooxygenase blocker), or combinations of these. Laser-Dopple…
Depressive symptoms and attenuated physiological reactivity to laboratory stressors.
2010
There is evidence that depressive symptoms are associated with attenuated physiological reactivity to active stressors. However, it is not known whether blunted reactivity in depressed individuals is stressor-specific. We examined cardiovascular and electrodermal reactivity in non-clinical participants with varying levels of depressive symptoms to different active and passive stressors. Depressive symptoms were inversely related to both blood pressure and skin conductance reactivity during a public speaking task and the viewing of the speech video. However, no effects were found during a cold pressor task. Together these findings suggest that depressive symptoms are related to attenuated sy…
Comparison of the sympathetic skin response and continuous wave Doppler sonography of the radial artery.
1999
The value of neurophysiological tests of the autonomic nerve system is limited. One of the clinically most commonly applied test is the skin sudomotor response, frequently referred to as 'sympathetic skin response' (SSR). However, the SSR is a more qualitative than quantitative evaluation technique. Continuous wave (cw) Doppler sonography of the radial artery may be an alternative quantitative approach. We studied 41 age matched volunteers (23 female, 18 male; 16-82 years (mean age 53 years)). The stimulus was a loud and unexpected acoustic signal, alternatively a cough. SSR evaluation included the latency of onset, the duration and the amplitude of the response. Doppler evaluation also inc…
Stress and thermoregulation: different sympathetic responses and different effects on experimental pain.
2009
Stress and thermoregulation both activate the sympathetic nervous system (SNS) but might differently affect pain. Studies investigating possible interactions in patients are problematic because of the high prevalence of SNS disturbances in patients. We therefore analyzed the influence of these different sympathetic challenges on experimentally-induced pain in healthy subjects. SNS was activated in two different ways: by mental stress (Stroop task, mental arithmetic task), and by thermoregulatory stimulation using a water-perfused thermal suit (7 degrees C, 32 degrees C, or 50 degrees C). Attentional effects of the mental stress tasks were controlled by using easy control tasks. Both, stress…
Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure
2011
We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…
Hypertension and peripheral arterial hemodynamics.
1995
Sixty uncomplicated hypertensive patients (30 stable and 30 borderline) were studied, by strain gauge plethysmography, in comparison with 25 normotensive subjects, in order to evaluate the arterial hemodynamics of the lower limbs in essential hypertension and to verify the different pattern in borderline and in stable hypertensives. Resting blood flow, even if slightly decreased in hypertensive groups, did not show significant differences in its mean values; peak flow, instead, was reduced proportionally to the severity of hypertension in all the hypertensive patients, but only in the stable hypertensives was it statistically significant. Minimal vascular resistance showed a similar behavi…
Correlation between non-invasive myocardial work indices and main parameters of systolic and diastolic function
2020
Abstract Aims The present study sought to evaluate the correlation between indices of non-invasive myocardial work (MW) and left ventricle (LV) size, traditional and advanced parameters of LV systolic and diastolic function by 2D echocardiography (2DE). Methods and results A total of 226 (85 men, mean age: 45 ± 13 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. Global work index (GWI), global constructive work (GCW), global work waste (GWW), and global work efficiency (GWE) were estimated from LV pressure-strain loops using custom software. Peak LV pressure was estimated non-invasively from brachial ar…
Three-year European follow-up of endovenous radiofrequency-powered segmental thermal ablation of the great saphenous vein with or without treatment o…
2011
BackgroundRadiofrequency segmental thermal ablation (RSTA) has become a commonly used technology for occlusion of incompetent great saphenous veins (GSVs). Midterm results and data on clinical parameters are still lacking.MethodsA prospective multicenteral trial monitored 295 RSTA-treated GSVs for 36 months. Clinical control visits included flow and reflux analysis by duplex ultrasound imaging and assessment of clinical parameters according to the CEAP classification and Venous Clinical Severity Score (VCSS).ResultsA total of 256 of 295 treated GSVs (86.4%) were available for 36 months of follow-up. At 36 months, Kaplan-Meier survival analysis showed the probability of occlusion was 92.6% a…
Pulsatile and steady 24-h blood pressure components as determinants of left ventricular mass in young and middle-aged essential hypertensives
2003
In order to explore the relations between left ventricular mass (LVM) and the pulsatile (pulse pressure) and steady (mean pressure) components of the blood pressure (BP) curve, 304 young and middle-aged essential hypertensive patients were studied by means of 24-h ambulatory BP monitoring and echocardiography. In the overall study population, both the BP components showed significant correlations with LVM. These correlations were unevenly distributed in the subgroups of subjects younger and in those older than 50 years. While in this latter subgroup, in multivariate analysis, both 24-h mean BP (24-MBP) (beta = 0.27; P = 0.008) and 24-h pulse pressure (24-h PP) (beta = 0.23; P = 0.02) were a…