Search results for "Bone Nails"
showing 10 items of 14 documents
The challenges of monoaxial bone transport in orthopedics and traumatology
2017
Background. Bone defects represent the main challenging problem for the orthopedic surgeon and, consequently, they increase the duration of hospitalization, risk of complications and health expenditures. The aim of our observational, descriptive and retrospective study is to evaluate the outcomes of patients treated with a monolateral external fixator for bone defects greater than 3 cm. Material and methods. Between January 2003 and January 2013, 21 patients were treated at our center by bone transfer with a monolateral external fixator. The main etiologies were trauma in 17 cases (80.9%) and tumors in 4 cases (19.1%). Mean follow-up was 5 years for non-union and 3 years for tumors. Our cl…
Clinical performance of a new medullary humeral nail: antegrade versus retrograde insertion.
2001
Objective A new intramedullary nail system for humeral shaft fractures is evaluated to determine whether retrograde nailing is as reliable as antegrade nailing. Study design Prospective multicenter nonrandomized clinical study. Patients Eighty-four patients with acute humeral shaft fractures were nailed with the new unreamed humeral nail (UHN) system. Fifty-seven nails were introduced retrogradely, and twenty-seven antegradely. Bone healing and functional outcome were the follow-up parameters. Results The ratio of perioperative complications was equivalent for both groups, but one shaft fracture and three fractures or fissures at the entry point occurred in the group with retrograde nail in…
The treatment of wrist fractures with Epibloc System
2011
BACKGROUND Fractures of the distal extremity of the radius are the most common bone lesions of the superior extremity of the body, representing 17% of the fractures treated in First Aid facilities. The restoration of anatomical relationships in the radiocarpal joint is considered to be a prerequisite for good functional recovery. There are numerous methods of treatment of these fractures. The Epibloc system is a percutaneous endomedullary synthesis alternative to the plaster cast in wrist fracture treatment. MATERIALS AND METHODS The authors describe their experience with 81 fractures (63 type A2-3 fractures and 18 type C1) of the wrist treated with the Epibloc System (ES). The results were…
Implantation of a polycaprolactone scaffold with subchondral bone anchoring ameliorates nodules formation and other tissue alterations
2015
Purpose: Articular cartilage has limited repair capacity. Two different implant devices for articular cartilage regeneration were tested in vivo in a sheep model to evaluate the effect of subchondral bone anchoring for tissue repair. Methods: The implants were placed with press-fit technique in a cartilage defect after microfracture surgery in the femoral condyle of the knee joint of the sheep and histologic and mechanical evaluation was done 4.5 months later. The first group consisted of a biodegradable polycaprolactone (PCL) scaffold with double porosity. The second test group consisted of a PCL scaffold attached to a poly(L-lactic acid) (PLLA) pin anchored to the subchondral bone. Result…
New intramedullary locking nail for olecranon fracture fixation--an in vitro biomechanical comparison with tension band wiring.
2010
The aim of this study was to determine the difference in displacement of a newly designed intramedullary olecranon fracture fixation device compared with multifilament tension band wiring after 4 cycles and 300 cycles of dynamic continuous loading.In eight pairs of fresh-frozen cadaver ulnae, oblique olecranon fractures were created and stabilized using either newly designed intramedullary olecranon nail or multifilament tension band wiring. The specimens were then subjected to continuous dynamic loading (from 25 N to 200 N) using matched pairs of cadaveric upper extremities. The Wilcoxon test was used to determine statistical differences of the displacement in the fracture gap.After 4 cycl…
Volar Fixed-Angle Plating of Distal Radius Fractures
2011
The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…
Dynamic biomechanical analysis of different olecranon fracture fixation devices--tension band wiring versus two intramedullary nail systems: an in-vi…
2007
Abstract Background. The aim of this study was to develop a test-setup with continuous angle alteration to imitate joint motion for the evaluation of 3 different olecranon fracture fixation devices. Methods. Twenty-one fresh cadaver upper extremities underwent olecranon fracture by the means of transverse osteotomy and received 3 different fixation systems. Group 1: Tension band wiring according to Weber. Group 2: XS-nail with 9 holes, all locked with 2 mm threaded K-wires. Group 3: Olecranon Nailing System with 90 mm length, locked with 2.7 mm screws, a variable angle locking hole for the proximal fragment and a proximal locking end cap. The servo-pneumatical test stand worked with a rotat…
Kuntscher nailing of femoral shaft fractures in children and adolescents.
1993
We have reviewed 29 cases of very unstable diaphyseal fractures of the femur in children and adolescents treated by Kuntscher nailing. Follow up was for at least 5 years, and in most cases until after the end of growth. There were no post-operative complications, and the mean overgrowth of the femur was 7.06 mm. There was growth disturbance of the proximal femur in one case, but this did not interfere with function. We believe that Kuntscher nailing is indicated in children and adolescents with unstable high velocity fractures of the femoral shaft.
Humeral nailing revisited.
2008
Unreamed interlocked humeral nailing for stabilisation of acute humeral fractures was introduced a decade ago. Antegrade and retrograde nail insertion are equally popular. The role of nailing as opposed to plating of humeral fractures is the subject of continuous debate. Between 1997 and 2005, 99 acute fractures of the humeral shaft were treated operatively with the unreamed humeral nail (UHN, Synthes) in our Level I Trauma Centre. The mean age of the patients was 63 years. Only eight patients (8.1%) were polytraumatised, nine patients had an open fracture (9.1%), five had a primary radial nerve palsy (5.1%). There were 54 antegrade and 45 retrograde nailings. The procedures were performed …
Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study
2011
Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calcula…