Search results for "Bone Plates"

showing 10 items of 27 documents

Volar Fixed-Angle Plating of Distal Radius Fractures

2011

The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…

MaleBone ScrewsBone NailsBiomechanical PhenomenaFracture Fixation InternalFixation (surgical)Fixed angleCadaverFracture fixationBone plateCadaverHumansMedicineOrthopedics and Sports MedicineAgedMechanical PhenomenaAged 80 and overOrthodonticsbusiness.industryGeneral MedicineRadiusMiddle AgedBiomechanical PhenomenaProsthesis FailureEquipment Failure AnalysisFemaleSurgeryRadius FracturesbusinessCadaveric spasmBone PlatesJournal of Orthopaedic Trauma
researchProduct

Intraosseous Fixation Compared to Plantar Plate Fixation for First Metatarsocuneiform Arthrodesis

2014

Background: Metatarsocuneiform (MTC) fusion is a treatment option for management of hallux valgus. We compared the biomechanical characteristics of an internal fixation device with plantar plate fixation. Methods: Seven matched pairs of feet from human cadavers were used to compare the intramedullary (IM) device plus compression screw to plantar plate combined with a compression screw. Specimen constructs were loaded in a cyclic 4-point bending test. We obtained initial/final stiffness, maximum load, and number of cycles to failure. Bone mineral density was measured with peripheral quantitative computed tomography. Performance was compared using time to event analysis with number of cycles …

Malemedicine.medical_specialtyArthrodesismedicine.medical_treatmentBone ScrewsArthrodesislaw.inventionIntramedullary rodFixation (surgical)lawCadavermedicineHumansInternal fixationOrthopedics and Sports MedicinePlantar plateHallux ValgusQuantitative computed tomographyAgedAged 80 and overOrthodonticsbiologymedicine.diagnostic_testbusiness.industryEquipment Designbiology.organism_classificationBiomechanical PhenomenaSurgeryValgusmedicine.anatomical_structureEquipment FailureFemaleSurgeryStress MechanicalTomography X-Ray ComputedCadaveric spasmbusinessBone PlatesFoot & Ankle International
researchProduct

Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible

2013

Introduction: After ablative surgery of the mandible, angular stable alloplastic reconstruction plates are commonly employed. The aim of the study was a long-term evaluation of local anatomical, as looking at systemic factors influencing specific complications and the failure rate of such plates. Materials and methods: In a retrospective study covering an 11-year period, we reviewed the outcomes of angular stable plates of patients who had a segmental resection of the mandible and subsequent alloplastic reconstruction. Complications and failure rates were assessed and local (anatomical size and localization of resection) as well as systemic risk factors (age, sex, radiation therapy, smoking…

Malemedicine.medical_specialtymedicine.medical_treatmentBone ScrewsBiocompatible MaterialsDehiscenceCumulative survivalCohort StudiesSex FactorsRisk FactorsSurgical Wound DehiscencemedicineHumansLongitudinal StudiesRisk factorDevice RemovalAgedRetrospective StudiesTitaniumbusiness.industrySmokingAge FactorsMandibleRadiotherapy DosageRetrospective cohort studyMiddle AgedSurvival AnalysisSurgeryRadiation therapyMandibular NeoplasmsTreatment OutcomeOtorhinolaryngologyCarcinoma Squamous CellEquipment FailureFemaleSurgeryMandibular ReconstructionOral SurgerySegmental resectionComplicationbusinessBone PlatesFollow-Up StudiesJournal of Cranio-Maxillofacial Surgery
researchProduct

Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study.

2005

The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1 cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2 mm with a load of 100 N. Increasing the load to 250 N revealed statistically significant differences in stiffness and failure load betwe…

Malemedicine.medical_treatmentVideo RecordingOsteotomyProsthesis DesignWeight-BearingFixation (surgical)Fracture Fixation InternalCadaverBone plateFracture fixationMaterials TestingmedicineDeformityCadaverHumansAgedOrthodonticsTransplantationbusiness.industryAnatomyOsteotomyEquipment Failure Analysismedicine.anatomical_structureSurgeryCortical boneFemalemedicine.symptombusinessRadius FracturesCancellous boneBone PlatesJournal of hand surgery (Edinburgh, Scotland)
researchProduct

Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study

2010

Purpose To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. Methods We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the …

Malemusculoskeletal diseasesmedicine.medical_specialtyBone ScrewsBendingFracture Fixation InternalFracture fixationBone platemedicineHumansOrthopedics and Sports MedicineAgedFixation (histology)Aged 80 and overOrthodonticsbusiness.industryBiomechanicsStiffnessRadiusMiddle Agedequipment and suppliesmusculoskeletal systemBiomechanical PhenomenaSurgeryEquipment Failure Analysissurgical procedures operativeOrthopedic surgeryFemaleSurgerymedicine.symptomRadius FracturesbusinessBone PlatesThe Journal of Hand Surgery
researchProduct

Photoelastic analysis of conventional and locking system for treatment of mandibular angle fractures with a single plate

2021

Made available in DSpace on 2021-06-25T10:28:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-04-01 Background: This photoelastic analysis evaluated stress distribution in different osteosynthesis systems, conventional and locking, used for treatment of mandibular angle fractures with a single plate. Material and Methods: Angle fractures were simulated in mandibles made of photoelastic resin. Following Champy’s method, plate osteosynthesis was performed. The samples were divided into five groups: Group 1, non-fractured mandible; Group 2, two screws were installed in each segment using a conventional system; Group 3, two screws were installed in each segment using a locking system; …

OrthodonticsPhotoelasticityUniversal testing machineOsteosynthesisMaterials scienceResearchMandibular fractureMandibleInternal fracture fixation030206 dentistrymedicine.diseaseMandibular first molarbone platesStress (mechanics)03 medical and health sciences0302 clinical medicinemandibular fractureBone platemedicineOral Surgery030223 otorhinolaryngologyosteosynthesisGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study

2011

Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calcula…

Orthodonticsanimal structuresOsteosynthesisCalcarbusiness.industryBone ScrewsVarus malalignmentStiffnessGeneral MedicineAnatomyBone NailsProsthesis DesignBiomechanical PhenomenaLocking plateRadiographyFracture Fixation InternalHumeral fractureShoulder FracturesHumansMedicineOrthopedics and Sports MedicineSurgerymedicine.symptombusinessBone PlatesJournal of Shoulder and Elbow Surgery
researchProduct

Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study

2010

Abstract Background The purpose of this study was to compare the stability of a 2.4 mm palmar locking compression plate and a new intramedullary nail-plate-hybrid Targon DR for dorsally comminuted distal radius fractures. Methods An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen human radii to simulate an AO–A3-fracture. The fractures were stabilized using one of the fixation methods. The specimens were loaded axially with 200 N and dorsal-excentrically with 80 N. 2000 cycles of dynamic loading and axial loading-to-failure were performed. Findings Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369 N/mm) was significantly ( p …

Orthodonticsmedicine.medical_specialtyMaterials scienceOsteosynthesisBiophysicsRadiusLocked platingIn Vitro TechniquesCompression (physics)Biomechanical PhenomenaFracture Fixation Intramedullarylaw.inventionSurgeryIntramedullary rodFracture Fixation InternalFixation (surgical)lawLoad to failureFresh frozenmedicineHumansOrthopedics and Sports MedicineRadius FracturesBone PlatesFractures ComminutedClinical Biomechanics
researchProduct

Volar and dorsal mid-shaft forearm plating using DCP and LC-DCP: interference with the interosseous membrane and forearm-kinematics.

2010

Purpose To clarify if dorsal plate osteosynthesis of the forearm shaft is associated with impingement of the interosseous membrane (IOM) and if rotational kinematics of the forearm are influenced. Background Forearm fractures are treated by separate incisions. Osteosynthesis via one approach in proximal forearm fractures was associated with higher rates of synostosis. It has been claimed that this is due to IOM impingement. Materials and methods 16 forearms of fresh frozen cadavers were dissected until only radius, ulna and the IOM remained. To preserve physiological forearm rotation, the elbow joint, the distal radio-ulnar joint and the carpus remained intact. In group 1, LC-DC and DC plat…

RotationElbowBone ScrewsProsthesis DesignSupinationFracture Fixation InternalForearmCadaverFracture fixationBone platemedicineCadaverHumansPronationAgedOsteosynthesisbusiness.industryInterosseous membraneUlnaForearm InjuriesGeneral MedicineAnatomyUlna FracturesBiomechanical Phenomenabody regionsForearmmedicine.anatomical_structureSurgerybusinessRadius FracturesBone PlatesActa chirurgica Belgica
researchProduct

Effectiveness of interceptive treatment of class III malocclusions with skeletal anchorage: A systematic review and meta-analysis

2017

Recently, new strategies for treating class III malocclusions have appeared. Skeletal anchorage appears to reduce the dentoalveolar effects while maximising the orthopaedic effect in growing patients. The purpose of this systematic review and meta-analysis is to examine the effectiveness of bone anchorage devices for interceptive treatment of skeletal class III malocclusions. Searches were made in the Pubmed, Embase, Scopus and Cochrane databases, as well as in a grey literature database, and were complemented by hand-searching. The criteria for eligibility were: patients who had undergone orthodontic treatment with skeletal anchorage (miniplates and miniscrews). Patients with syndromes or …

TeethPhysiologyOverjetDigestive PhysiologyBone Screwslcsh:MedicineOrthodontics InterceptiveDatabase and Informatics Methods0302 clinical medicineMathematical and Statistical TechniquesMedicine and Health SciencesMaxillaOrthodontic Anchorage Procedures030212 general & internal medicineDatabase Searchinglcsh:ScienceMusculoskeletal SystemOrthodonticsMultidisciplinaryResearch AssessmentSystematic reviewTreatment OutcomeMeta-analysisPhysical SciencesAnatomyBone PlatesStatistics (Mathematics)Research ArticleSystematic ReviewsOral MedicineMEDLINESurgical and Invasive Medical ProceduresOrthodonticsMolarsResearch and Analysis Methods03 medical and health sciencesBone platemedicineDentitionExtraoral Traction AppliancesHumansCraniofacialStatistical MethodsInterceptive TreatmentSkeletonbusiness.industrylcsh:RBiology and Life Sciences030206 dentistrymedicine.diseaseMalocclusion Angle Class IIIJawlcsh:QMalocclusionbusinessDigestive SystemHeadMathematicsMeta-AnalysisPLoS ONE
researchProduct