Search results for "Bone plate"

showing 10 items of 41 documents

Treatment of multiple traumatized anterior teeth associated with an alveolar bone fracture in a 20-year-old patient: A 3-year follow up

2014

Intrusive luxation is a type of recognizable luxation injury represented by a deeper axial displacement of the tooth toward the alveolar bone. Treatment strategies include waiting for the tooth to return to its position, immediate surgical repositioning, and repositioning through dental traction by orthodontic devices. The aim of this case report was to present the management of severe dental trauma and later restoration following IADT. A 20-year-old patient was presented after fainting at home four hours before, resulting in a dento-alveolar trauma. Clinical examinations revealed a traumatic intrusion, in 1.2, 1.1 and 2.1, uncomplicated crown fractures in 1.1 and 2.1 and a complicated crow…

Dental traumabusiness.industryRoot canalDentistryOdontologíaCase ReportEmergency treatmentmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Feldspathic ceramicOral hygieneCiencias de la saludstomatognathic diseasesmedicine.anatomical_structurestomatognathic systemIntegral DentistryUNESCO::CIENCIAS MÉDICASBone plateMedicinebusinessGeneral DentistryAnterior teethDental alveolusJournal of Clinical and Experimental Dentistry
researchProduct

The oxidizing agent tertiary butyl hydroperoxide induces disturbances in spindle organization, c-meiosis, and aneuploidy in mouse oocytes

1996

It has been recently proposed that a concomitant generation of oxidative stress of oocytes with increasing maternal age may be a major factor responsible for the age-related increase in aneuploid conceptions. As a preliminary step in the testing of this hypothesis, we need to confirm that oxidative stress in itself can induce errors in chromosome segregation. In order to achieve this goal, germinal vesicle (GV)-stage mouse oocytes from unstimulated ICR and (C57BL x CBA) F1 hybrid female mice were matured in vitro for 9 h for metaphase I (MI) oocytes or 16 h for metaphase II (MII) oocytes in the presence of varying concentrations of the oxidizing agent tertiary-butyl hydroperoxide (tBH). MII…

EmbryologyAneuploidyIn Vitro TechniquesBiologyChromosome segregationMicetert-ButylhydroperoxideMeiosisBone plateGeneticsmedicineAnimalsHumansMolecular BiologyMice Inbred ICRMicroscopy ConfocalGerminal vesicleMeiosis IIObstetrics and GynecologyCell BiologyAneuploidyOxidantsmedicine.diseaseOocyteMolecular biologyPeroxidesCell biologyMice Inbred C57BLMeiosisOxidative Stressmedicine.anatomical_structureReproductive MedicineMice Inbred CBAOocytesSpindle organizationFemaleMaternal AgeDevelopmental Biology
researchProduct

Efficacy of Zero-Profile Device versus Plate and Cage Implant for Treatment of Symptomatic Adjacent Segment Disease After Anterior Cervical Diskectom…

2018

Fusionmedicine.medical_specialtybusiness.industrySurgery03 medical and health sciencesanterior discectomy and fusion cervical hybrid surgery0302 clinical medicineText miningSpinal FusionCervical diskectomy030220 oncology & carcinogenesisCervical VertebraeMedicineSurgeryNeurology (clinical)Adjacent segment diseaseImplantbusinessCageBone Plates030217 neurology & neurosurgeryDiskectomy
researchProduct

Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior…

2009

Objectives: Two 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated. Methods: Eight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epic…

Joint InstabilityMalemusculoskeletal diseasesHumeral Fracturesmedicine.medical_specialtyCompressive StrengthBone ScrewsUlnaBendingWeight-BearingElastic ModulusProsthesis FittingTensile StrengthElbow JointmedicineHumansOrthopedics and Sports MedicineHumerusAged 80 and overOrthodonticsOsteosynthesisbusiness.industryBiomechanicsStiffnessGeneral MedicineMiddle Agedmusculoskeletal systemSurgeryTreatment Outcomemedicine.anatomical_structureFracture (geology)FemaleSurgeryImplantmedicine.symptomElbow InjuriesEpicondylebusinessBone PlatesJournal of Orthopaedic Trauma
researchProduct

Leg Extension Power and Walking Speed in Very Old People Living Independently

1997

BACKGROUND Leg extension power can be determined as the product of the force and velocity of movement. Its association with maximal walking speed was studied in 131 80- and 85-year-old men and women. METHODS Leg extension power was measured with the help of a sledge ergometer in a sitting position using a facilitated "jump test." The participant was attached by belts to a sliding chair on rails inclined at 12.6 degrees to the floor. The feet were placed on the force plate attached perpendicularly to the rails, and the knee angle was 90 degrees at the starting position. The participant was advised to extend his or her legs powerfully. The highest value of five to eight attempts was accepted …

MaleAgingmedicine.medical_specialtyTime FactorsPower walkingPoison controlWalkingMotor ActivitySittingActivities of Daily LivingBone plateHumansMedicineAgedAged 80 and overLegSex CharacteristicsWattbusiness.industryPower (physics)Preferred walking speedPhysical therapyFemaleLeg extensionGeriatrics and GerontologybusinessThe Journals of Gerontology Series A: Biological Sciences and Medical Sciences
researchProduct

Volar Fixed-Angle Plating of Distal Radius Fractures

2011

The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…

MaleBone ScrewsBone NailsBiomechanical PhenomenaFracture Fixation InternalFixation (surgical)Fixed angleCadaverFracture fixationBone plateCadaverHumansMedicineOrthopedics and Sports MedicineAgedMechanical PhenomenaAged 80 and overOrthodonticsbusiness.industryGeneral MedicineRadiusMiddle AgedBiomechanical PhenomenaProsthesis FailureEquipment Failure AnalysisFemaleSurgeryRadius FracturesbusinessCadaveric spasmBone PlatesJournal of Orthopaedic Trauma
researchProduct

Intraosseous Fixation Compared to Plantar Plate Fixation for First Metatarsocuneiform Arthrodesis

2014

Background: Metatarsocuneiform (MTC) fusion is a treatment option for management of hallux valgus. We compared the biomechanical characteristics of an internal fixation device with plantar plate fixation. Methods: Seven matched pairs of feet from human cadavers were used to compare the intramedullary (IM) device plus compression screw to plantar plate combined with a compression screw. Specimen constructs were loaded in a cyclic 4-point bending test. We obtained initial/final stiffness, maximum load, and number of cycles to failure. Bone mineral density was measured with peripheral quantitative computed tomography. Performance was compared using time to event analysis with number of cycles …

Malemedicine.medical_specialtyArthrodesismedicine.medical_treatmentBone ScrewsArthrodesislaw.inventionIntramedullary rodFixation (surgical)lawCadavermedicineHumansInternal fixationOrthopedics and Sports MedicinePlantar plateHallux ValgusQuantitative computed tomographyAgedAged 80 and overOrthodonticsbiologymedicine.diagnostic_testbusiness.industryEquipment Designbiology.organism_classificationBiomechanical PhenomenaSurgeryValgusmedicine.anatomical_structureEquipment FailureFemaleSurgeryStress MechanicalTomography X-Ray ComputedCadaveric spasmbusinessBone PlatesFoot & Ankle International
researchProduct

Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible

2013

Introduction: After ablative surgery of the mandible, angular stable alloplastic reconstruction plates are commonly employed. The aim of the study was a long-term evaluation of local anatomical, as looking at systemic factors influencing specific complications and the failure rate of such plates. Materials and methods: In a retrospective study covering an 11-year period, we reviewed the outcomes of angular stable plates of patients who had a segmental resection of the mandible and subsequent alloplastic reconstruction. Complications and failure rates were assessed and local (anatomical size and localization of resection) as well as systemic risk factors (age, sex, radiation therapy, smoking…

Malemedicine.medical_specialtymedicine.medical_treatmentBone ScrewsBiocompatible MaterialsDehiscenceCumulative survivalCohort StudiesSex FactorsRisk FactorsSurgical Wound DehiscencemedicineHumansLongitudinal StudiesRisk factorDevice RemovalAgedRetrospective StudiesTitaniumbusiness.industrySmokingAge FactorsMandibleRadiotherapy DosageRetrospective cohort studyMiddle AgedSurvival AnalysisSurgeryRadiation therapyMandibular NeoplasmsTreatment OutcomeOtorhinolaryngologyCarcinoma Squamous CellEquipment FailureFemaleSurgeryMandibular ReconstructionOral SurgerySegmental resectionComplicationbusinessBone PlatesFollow-Up StudiesJournal of Cranio-Maxillofacial Surgery
researchProduct

Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study.

2005

The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1 cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2 mm with a load of 100 N. Increasing the load to 250 N revealed statistically significant differences in stiffness and failure load betwe…

Malemedicine.medical_treatmentVideo RecordingOsteotomyProsthesis DesignWeight-BearingFixation (surgical)Fracture Fixation InternalCadaverBone plateFracture fixationMaterials TestingmedicineDeformityCadaverHumansAgedOrthodonticsTransplantationbusiness.industryAnatomyOsteotomyEquipment Failure Analysismedicine.anatomical_structureSurgeryCortical boneFemalemedicine.symptombusinessRadius FracturesCancellous boneBone PlatesJournal of hand surgery (Edinburgh, Scotland)
researchProduct

Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study

2010

Purpose To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. Methods We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the …

Malemusculoskeletal diseasesmedicine.medical_specialtyBone ScrewsBendingFracture Fixation InternalFracture fixationBone platemedicineHumansOrthopedics and Sports MedicineAgedFixation (histology)Aged 80 and overOrthodonticsbusiness.industryBiomechanicsStiffnessRadiusMiddle Agedequipment and suppliesmusculoskeletal systemBiomechanical PhenomenaSurgeryEquipment Failure Analysissurgical procedures operativeOrthopedic surgeryFemaleSurgerymedicine.symptomRadius FracturesbusinessBone PlatesThe Journal of Hand Surgery
researchProduct