Search results for "Bone plate"
showing 10 items of 41 documents
Treatment of multiple traumatized anterior teeth associated with an alveolar bone fracture in a 20-year-old patient: A 3-year follow up
2014
Intrusive luxation is a type of recognizable luxation injury represented by a deeper axial displacement of the tooth toward the alveolar bone. Treatment strategies include waiting for the tooth to return to its position, immediate surgical repositioning, and repositioning through dental traction by orthodontic devices. The aim of this case report was to present the management of severe dental trauma and later restoration following IADT. A 20-year-old patient was presented after fainting at home four hours before, resulting in a dento-alveolar trauma. Clinical examinations revealed a traumatic intrusion, in 1.2, 1.1 and 2.1, uncomplicated crown fractures in 1.1 and 2.1 and a complicated crow…
The oxidizing agent tertiary butyl hydroperoxide induces disturbances in spindle organization, c-meiosis, and aneuploidy in mouse oocytes
1996
It has been recently proposed that a concomitant generation of oxidative stress of oocytes with increasing maternal age may be a major factor responsible for the age-related increase in aneuploid conceptions. As a preliminary step in the testing of this hypothesis, we need to confirm that oxidative stress in itself can induce errors in chromosome segregation. In order to achieve this goal, germinal vesicle (GV)-stage mouse oocytes from unstimulated ICR and (C57BL x CBA) F1 hybrid female mice were matured in vitro for 9 h for metaphase I (MI) oocytes or 16 h for metaphase II (MII) oocytes in the presence of varying concentrations of the oxidizing agent tertiary-butyl hydroperoxide (tBH). MII…
Efficacy of Zero-Profile Device versus Plate and Cage Implant for Treatment of Symptomatic Adjacent Segment Disease After Anterior Cervical Diskectom…
2018
Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior…
2009
Objectives: Two 90-degree configurations of locking reconstruction plates with different numbers of screws in the distal ulnar column segment of distal extra-articular humeral fractures with metaphyseal comminution (A3) were biomechanically investigated. Methods: Eight pairs of fresh-frozen human humeri were used. For paired comparison, the humeri were divided into 2 randomized groups. In both groups, double-plate osteosyntheses with locking reconstruction plates were performed in 90-degree configurations. In group 1, the posteriorly placed radial column plate exceeded the capitellum and the ulnar column plate extended into the ulnar sulcus. The ulnar plate was molded around the medial epic…
Leg Extension Power and Walking Speed in Very Old People Living Independently
1997
BACKGROUND Leg extension power can be determined as the product of the force and velocity of movement. Its association with maximal walking speed was studied in 131 80- and 85-year-old men and women. METHODS Leg extension power was measured with the help of a sledge ergometer in a sitting position using a facilitated "jump test." The participant was attached by belts to a sliding chair on rails inclined at 12.6 degrees to the floor. The feet were placed on the force plate attached perpendicularly to the rails, and the knee angle was 90 degrees at the starting position. The participant was advised to extend his or her legs powerfully. The highest value of five to eight attempts was accepted …
Volar Fixed-Angle Plating of Distal Radius Fractures
2011
The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…
Intraosseous Fixation Compared to Plantar Plate Fixation for First Metatarsocuneiform Arthrodesis
2014
Background: Metatarsocuneiform (MTC) fusion is a treatment option for management of hallux valgus. We compared the biomechanical characteristics of an internal fixation device with plantar plate fixation. Methods: Seven matched pairs of feet from human cadavers were used to compare the intramedullary (IM) device plus compression screw to plantar plate combined with a compression screw. Specimen constructs were loaded in a cyclic 4-point bending test. We obtained initial/final stiffness, maximum load, and number of cycles to failure. Bone mineral density was measured with peripheral quantitative computed tomography. Performance was compared using time to event analysis with number of cycles …
Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible
2013
Introduction: After ablative surgery of the mandible, angular stable alloplastic reconstruction plates are commonly employed. The aim of the study was a long-term evaluation of local anatomical, as looking at systemic factors influencing specific complications and the failure rate of such plates. Materials and methods: In a retrospective study covering an 11-year period, we reviewed the outcomes of angular stable plates of patients who had a segmental resection of the mandible and subsequent alloplastic reconstruction. Complications and failure rates were assessed and local (anatomical size and localization of resection) as well as systemic risk factors (age, sex, radiation therapy, smoking…
Locking plates for corrective osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study.
2005
The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver model. A 1 cm metaphyseal osteotomy gap was made to simulate a corrective osteotomy and the osteotomy plated. Axial load was applied to the distal end of each construct by a material testing machine under control of a motion analysis video system. The specimens were arranged into five implant groups of eight specimens each. No test group developed deformity and movement of the fracture gap greater than 2 mm with a load of 100 N. Increasing the load to 250 N revealed statistically significant differences in stiffness and failure load betwe…
Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study
2010
Purpose To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. Methods We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the …