Search results for "Bone plate"

showing 10 items of 41 documents

Traitement chirurgical des fractures du condyle mandibulaire de l'adulte en France en 2005

2007

Summary Introduction The authors had for aim to present the latest trends in the surgical management of mandibular condylar fractures in France, in 2005. Material and methods One hundred maxillofacial surgeons were questioned on the surgical management of condylar fractures and indications. Results were presented at the 41st Congress of Stomatology and Maxillofacial surgery. Results The overall reply rate was 70%. Condylar fractures are generally managed in teaching hospitals. Open reduction and fixation was deemed appropriate in low subcondylar fractures in 76% of the cases, in 10% for diacapitular fractures. Therapeutic details and indications were a matter of huge variability. Discussion…

Maxillofacial surgeonsTreatment protocolbusiness.industryDentistryJaw Fixation TechniquesCondyleTemporomandibular jointmedicine.anatomical_structurestomatognathic systemOtorhinolaryngologyBone plateMedicineSurgeryOral SurgerybusinessRevue de Stomatologie et de Chirurgie Maxillo-faciale
researchProduct

Radiological implications of crestal and subcrestal implant placement in posterior areas. A cone-beam computed tomography study

2020

Background Subcrestal implant placement has been suggested as a method that could contribute to maintain the periimplant soft and hard tissues in comparison with crestal placement. The objective of this study was to investigate the relationship between implant placement at different depths in the alveolar bone and (a) the thickness of the buccal bone plate (BBP); and (b) crestal cortical bone thickness, based on the use of cone-beam computed tomography (CBCT). Material and Methods A cross-sectional study was performed, analyzing CBCT scans from the database of the Oral Surgery Unit of the University of Valencia. Individuals with single missing teeth in posterior sectors were included. Two t…

OrthodonticsCone beam computed tomographybusiness.industryResearchBone crest:CIENCIAS MÉDICAS [UNESCO]Implant placementmedicine.anatomical_structureRadiological weaponBone plateUNESCO::CIENCIAS MÉDICASmedicineCortical boneImplantOral SurgerybusinessGeneral DentistryDental alveolus
researchProduct

Soft-tissue cone-beam computed tomography (ST-CBCT) technique for the analysis of skeletal, dental and periodontal effects of orthopedic rapid maxill…

2018

Background Orthopedic rapid maxillary expansion (RME) is a common treatment of choice for managing transverse deficiency of the maxilla. This approach may have desired and undesired skeletal, dental and periodontal effects that may be assessed clinically or through imaging techniques. This study aims to investigate the dental, skeletal and periodontal effects of orthopedic RME using the soft-tissue cone-beam computed tomography (CBCT) technique. Material and Methods The sample consisted of 10 patients (5males and 5 females) aged between 10 and 14 years (mean age: 12.5 years) treated with Hyrax orthopedic device. CBCT scans set for the registration of soft tissue (ST-CBCT) were taken from ea…

OrthodonticsMolarmedicine.medical_specialtyCone beam computed tomographybusiness.industryResearchSoft tissueOrthodontics030206 dentistry:CIENCIAS MÉDICAS [UNESCO]03 medical and health sciencesDental archstomatognathic diseases0302 clinical medicinemedicine.anatomical_structurestomatognathic systemMaxillaUNESCO::CIENCIAS MÉDICASOrthopedic surgeryBone platemedicinebusinessGeneral Dentistry030217 neurology & neurosurgeryDental alveolusJournal of clinical and experimental dentistry
researchProduct

Osteosynthese am proximalen Humerus mittels winkelstabiler Platte oder Doppelplatte: eine vergleichende biomechanische Untersuchung / Angle-fixed pla…

2008

Internal fixation of fractures of the proximal humerus needs a high stability of fixation to avoid secondary loss of fixation. This is especially important in osteoporotic bone. In an experimental study, the biomechanical properties of the angle-fixed Philos plate (internal fixator) and a double-plate osteosynthesis using two one-third tubular plates were assessed. The fracture model was an unstable three-part fracture (AO type B2). Eight pairs of human cadaveric humeri were submitted to axial load and torque. In the first part of the study, it was assessed to which degree the original stiffness of the humeri could be restored after the osteotomy by the osteosynthesis procedure. Subsequentl…

OrthodonticsOsteosynthesismedicine.medical_treatmentBiomedical EngineeringBiomechanicsAnatomyOsteotomymedicine.anatomical_structureFracture fixationBone platemedicineInternal fixationHumerusCadaveric spasmBiomedizinische Technik/Biomedical Engineering
researchProduct

Photoelastic analysis of conventional and locking system for treatment of mandibular angle fractures with a single plate

2021

Made available in DSpace on 2021-06-25T10:28:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-04-01 Background: This photoelastic analysis evaluated stress distribution in different osteosynthesis systems, conventional and locking, used for treatment of mandibular angle fractures with a single plate. Material and Methods: Angle fractures were simulated in mandibles made of photoelastic resin. Following Champy’s method, plate osteosynthesis was performed. The samples were divided into five groups: Group 1, non-fractured mandible; Group 2, two screws were installed in each segment using a conventional system; Group 3, two screws were installed in each segment using a locking system; …

OrthodonticsPhotoelasticityUniversal testing machineOsteosynthesisMaterials scienceResearchMandibular fractureMandibleInternal fracture fixation030206 dentistrymedicine.diseaseMandibular first molarbone platesStress (mechanics)03 medical and health sciences0302 clinical medicinemandibular fractureBone platemedicineOral Surgery030223 otorhinolaryngologyosteosynthesisGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study

2011

Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calcula…

Orthodonticsanimal structuresOsteosynthesisCalcarbusiness.industryBone ScrewsVarus malalignmentStiffnessGeneral MedicineAnatomyBone NailsProsthesis DesignBiomechanical PhenomenaLocking plateRadiographyFracture Fixation InternalHumeral fractureShoulder FracturesHumansMedicineOrthopedics and Sports MedicineSurgerymedicine.symptombusinessBone PlatesJournal of Shoulder and Elbow Surgery
researchProduct

Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study

2010

Abstract Background The purpose of this study was to compare the stability of a 2.4 mm palmar locking compression plate and a new intramedullary nail-plate-hybrid Targon DR for dorsally comminuted distal radius fractures. Methods An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen human radii to simulate an AO–A3-fracture. The fractures were stabilized using one of the fixation methods. The specimens were loaded axially with 200 N and dorsal-excentrically with 80 N. 2000 cycles of dynamic loading and axial loading-to-failure were performed. Findings Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369 N/mm) was significantly ( p …

Orthodonticsmedicine.medical_specialtyMaterials scienceOsteosynthesisBiophysicsRadiusLocked platingIn Vitro TechniquesCompression (physics)Biomechanical PhenomenaFracture Fixation Intramedullarylaw.inventionSurgeryIntramedullary rodFracture Fixation InternalFixation (surgical)lawLoad to failureFresh frozenmedicineHumansOrthopedics and Sports MedicineRadius FracturesBone PlatesFractures ComminutedClinical Biomechanics
researchProduct

Volar and dorsal mid-shaft forearm plating using DCP and LC-DCP: interference with the interosseous membrane and forearm-kinematics.

2010

Purpose To clarify if dorsal plate osteosynthesis of the forearm shaft is associated with impingement of the interosseous membrane (IOM) and if rotational kinematics of the forearm are influenced. Background Forearm fractures are treated by separate incisions. Osteosynthesis via one approach in proximal forearm fractures was associated with higher rates of synostosis. It has been claimed that this is due to IOM impingement. Materials and methods 16 forearms of fresh frozen cadavers were dissected until only radius, ulna and the IOM remained. To preserve physiological forearm rotation, the elbow joint, the distal radio-ulnar joint and the carpus remained intact. In group 1, LC-DC and DC plat…

RotationElbowBone ScrewsProsthesis DesignSupinationFracture Fixation InternalForearmCadaverFracture fixationBone platemedicineCadaverHumansPronationAgedOsteosynthesisbusiness.industryInterosseous membraneUlnaForearm InjuriesGeneral MedicineAnatomyUlna FracturesBiomechanical Phenomenabody regionsForearmmedicine.anatomical_structureSurgerybusinessRadius FracturesBone PlatesActa chirurgica Belgica
researchProduct

Effectiveness of interceptive treatment of class III malocclusions with skeletal anchorage: A systematic review and meta-analysis

2017

Recently, new strategies for treating class III malocclusions have appeared. Skeletal anchorage appears to reduce the dentoalveolar effects while maximising the orthopaedic effect in growing patients. The purpose of this systematic review and meta-analysis is to examine the effectiveness of bone anchorage devices for interceptive treatment of skeletal class III malocclusions. Searches were made in the Pubmed, Embase, Scopus and Cochrane databases, as well as in a grey literature database, and were complemented by hand-searching. The criteria for eligibility were: patients who had undergone orthodontic treatment with skeletal anchorage (miniplates and miniscrews). Patients with syndromes or …

TeethPhysiologyOverjetDigestive PhysiologyBone Screwslcsh:MedicineOrthodontics InterceptiveDatabase and Informatics Methods0302 clinical medicineMathematical and Statistical TechniquesMedicine and Health SciencesMaxillaOrthodontic Anchorage Procedures030212 general & internal medicineDatabase Searchinglcsh:ScienceMusculoskeletal SystemOrthodonticsMultidisciplinaryResearch AssessmentSystematic reviewTreatment OutcomeMeta-analysisPhysical SciencesAnatomyBone PlatesStatistics (Mathematics)Research ArticleSystematic ReviewsOral MedicineMEDLINESurgical and Invasive Medical ProceduresOrthodonticsMolarsResearch and Analysis Methods03 medical and health sciencesBone platemedicineDentitionExtraoral Traction AppliancesHumansCraniofacialStatistical MethodsInterceptive TreatmentSkeletonbusiness.industrylcsh:RBiology and Life Sciences030206 dentistrymedicine.diseaseMalocclusion Angle Class IIIJawlcsh:QMalocclusionbusinessDigestive SystemHeadMathematicsMeta-AnalysisPLoS ONE
researchProduct

Interactions in the network of Usher syndrome type 1 proteins

2004

International audience; Defects in myosin VIIa, harmonin (a PDZ domain protein), cadherin 23, protocadherin 15 and sans (a putative scaffolding protein), underlie five forms of Usher syndrome type I (USH1). Mouse mutants for all these proteins exhibit disorganization of their hair bundle, which is the mechanotransduction receptive structure of the inner ear sensory cells, the cochlear and vestibular hair cells. We have previously demonstrated that harmonin interacts with cadherin 23 and myosin VIIa. Here we address the extent of interactions between the five known USH1 proteins. We establish the previously suggested sans-harmonin interaction and find that sans also binds to myosin VIIa. We …

[SDV]Life Sciences [q-bio]Hearing Loss SensorineuralStereocilia (inner ear)PDZ domainCadherin Related ProteinsProtocadherinCell Cycle ProteinsNerve Tissue ProteinsCuticular plateMyosinsBiologyMiceTwo-Hybrid System TechniquesHair Cells AuditoryBone plateMyosinotorhinolaryngologic diseasesGeneticsAnimalsHumansProtein PrecursorsMolecular BiologyGenetics (clinical)GeneticsStereociliumDyneinsSyndromeGeneral MedicineCadherinsCell biologyCytoskeletal ProteinsMyosin VIIaMutationsense organsCarrier ProteinsRetinitis PigmentosaPCDH15HeLa CellsProtein BindingHuman Molecular Genetics
researchProduct